共 43 条
Comparative effectiveness of intracranial hypertension management guided by ventricular versus intraparenchymal pressure monitoring: a CENTER-TBI study
被引:0
|作者:
Victor Volovici
Dana Pisică
Benjamin Y. Gravesteijn
Clemens M. F. Dirven
Ewout W. Steyerberg
Ari Ercole
Nino Stocchetti
David Nelson
David K. Menon
Giuseppe Citerio
Mathieu van der Jagt
Andrew I. R. Maas
Iain K. Haitsma
Hester F. Lingsma
机构:
[1] Erasmus MC,Department of Neurosurgery
[2] Erasmus MC University Medical Center,Department of Public Health, Center for Medical Decision Making
[3] Erasmus MC Stroke Center,Department of Medical Statistics and Bioinformatics
[4] Leiden University Medical Center,Division of Anesthesia
[5] University of Cambridge,Neuroscience Intensive Care Unit, Department of Anesthesia and Critical Care
[6] Addenbrooke’s Hospital,Department of Pathophysiology and Transplantation
[7] Fondazione IRCCS Ca’ Granda - Ospedale Maggiore Policlinico,School of Medicine and Surgery
[8] University of Milan,Department of Intensive Care Adults
[9] Section of Perioperative Medicine and Intensive Care,Department of Neurosurgery
[10] Department of Physiology and Pharmacology,undefined
[11] Karolinska Institutet,undefined
[12] University of Milan-Bicocca,undefined
[13] Neurointensive Care,undefined
[14] San Gerardo Hospital,undefined
[15] ASST,undefined
[16] Erasmus MC,undefined
[17] UZ Antwerp University Hospital,undefined
来源:
关键词:
External ventricular devices;
Intraparenchymal monitors;
Intracranial pressure monitoring;
Severe TBI;
Traumatic brain injury;
CENTER-TBI;
Intracranial hypertension;
EVD;
ICP;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
引用
收藏
页码:1693 / 1705
页数:12
相关论文