“The effect of diode laser 940 nm and 445 nm on the rise in temperature of a pulp simulating material: in vitro study”

被引:0
|
作者
Bahaaeldin B. [1 ]
Fahmy O.I. [1 ]
Zoghaby A. [2 ]
Franzen R. [3 ,4 ,5 ]
机构
[1] Restorative Dentistry Department, Misr International University, KM 28 Cairo - Ismailia Road Ahmed Orabi District, Cairo
[2] Restorative Dentistry Department, Cairo University, Cairo
[3] AALZ Aachen Dental Laser Center, Aachen
[4] Dental Department, SFU Sigmund Freud University, Vienna
[5] Basic Science Department, Misr International University, Cairo
关键词
445 nm diode laser; Blue laser; Temperature rise;
D O I
10.1007/s41547-023-00191-4
中图分类号
学科分类号
摘要
Purpose: The purpose of the current study was to compare the effect of two diode lasers with wavelengths (940 nm and 445 nm) using different powers (0.5 W and 1 W) on the temperature rise of a pulp simulating material. Materials and methods: This in vitro study involved a total number of 36 permanent molars. The samples were randomly divided into two groups according to different wavelengths (940 nm and 445 nm); 18 teeth were included in each group. Each group was subdivided according to the power settings (0.5 and 1 W) into two subgroups with nine teeth in each subgroup. The occlusal cavities were prepared in sound molars leaving a 1 mm dentin bridge. The selected wavelengths were applied for 5 s with an output of 0.5 W and 1 W. The applied energy was 2.5 J and 5 J. A thermocouple was inserted in the pulp chamber filled with a pulp simulating material, and the temperature changes were monitored in °C throughout the procedure. The data collected were tabulated and statistically analyzed by using tests of normality (Kolmogorov–Smirnov and Shapiro–Wilk tests). Results: The results had shown that the 940 nm has a higher statistical significance difference on the mean temperature in comparison to the 445 nm at 0.5 W. The 940 nm showed a higher temperature rise compared to the 445 nm using the 1 W, yet it is insignificant. However, there was no statistically significant difference in the temperature rise between both powers (0.5W and 1 W) in both wavelengths (445 nm and 940 nm). Nevertheless, all the temperature rises that occurred did not exceed 2 °C. Conclusion: Both wavelengths increased the temperature of the pulp simulating material. The 940 nm caused a higher increase in temperature. The temperature elevations were within the safe range, providing that both wavelengths can be used safely with the used parameters. © 2023, The Author(s), under exclusive licence to Springer Nature Switzerland AG.
引用
收藏
页码:147 / 153
页数:6
相关论文
共 50 条
  • [41] Effects of different settings for 940 nm diode laser on expanded suture in rats
    Deynek, Gul Tas
    Ramoglu, Sabri Ilhan
    ANGLE ORTHODONTIST, 2019, 89 (03) : 446 - 454
  • [42] 400 mW external cavity diode laser with narrowband emission at 445 nm
    Ruhnke, N.
    Mueller, A.
    Eppich, B.
    Maiwald, M.
    Sumpf, B.
    Erbert, G.
    Traenkle, G.
    OPTICS LETTERS, 2014, 39 (13) : 3794 - 3797
  • [43] Treatment of recurrent minor aphthous stomatitis using diode laser (940 nm)
    Ghali, Hussien G. H.
    Abdulhamed, Balsam Saadi
    JOURNAL OF POPULATION THERAPEUTICS AND CLINICAL PHARMACOLOGY, 2021, 28 (02): : E99 - E112
  • [44] The effect of bleaching gel and (940nm and 980nm) diode lasers photoactivation on intrapulpal temperature and teeth whitening efficiency
    Al-Karadaghi, Tamara S.
    Al-Saedi, Asmaa A.
    Al-Maliky, Mohammed A.
    Mahmood, Ali S.
    AUSTRALIAN ENDODONTIC JOURNAL, 2016, 42 (03) : 112 - 118
  • [45] Effect of diode lasers with wavelength of 445 and 980 nm on a temperature rise when uncovering implants for second stage surgery: An ex-vivo study in pigs
    Matys, Jacek
    Flieger, Rafal
    Dominiak, Marzena
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 26 (04): : 687 - 693
  • [46] Antimicrobial Effect of 940 nm Diode Laser based on Photolysis of Hydrogen Peroxide in the Treatment of Periodontal Disease
    Odor, Alin Alexandru
    Bechir, Edwin Sever
    Violant, Deborah
    Badea, Victoria
    REVISTA DE CHIMIE, 2018, 69 (08): : 2081 - 2088
  • [47] The Photothermal Effect of 940nm Diode Laser on Enterococcus Faecalis Biofilm in Infected Root Canal
    Buraihi, Mustafa M.
    Alkurtas, Salah A.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2020, 8 (07): : 480 - 486
  • [48] Analysis of Human Tooth Pulp Chamber Temperature After 670 nm Laser Irradiation: In Vitro Study
    Alves Carrara de Oliveir, Cleide Regina
    Zanin, Fatima
    Cassoni, Alessandra
    Rodrigues, Jose Augusto
    Silveira, Landulfo, Jr.
    Pacheco, Marcos Tadeu
    Brugnera Junior, Aldo
    PHOTOMEDICINE AND LASER SURGERY, 2017, 35 (10) : 515 - 519
  • [49] Randomized Controlled Trial: Comparative Efficacy for the Treatment of Facial Telangiectasias With 532 nm Versus 940 nm Diode Laser
    Tierney, Emily
    Hanke, C. William
    LASERS IN SURGERY AND MEDICINE, 2009, 41 (08) : 555 - 562
  • [50] Cryogenic laser performance of Yb:YAG diode-pumped at 940 nm and 969 nm for high power lasers
    Jambunathan, Venkatesan
    Tesnohlidkova, Lucie
    Miura, Taisuke
    Lucianetti, Antonio
    Mocek, Tomas
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,