Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

被引:0
|
作者
R. Brüning
K. Seelos
T. Yousry
J. Scheidler
H. Exner
U. Porn
M. Reiser
B. R. Rosen
机构
[1] Institute of Diagnostic Radiology,
[2] Klinikum Grosshadern,undefined
[3] University of Munich,undefined
[4] D-81366 Munich,undefined
[5] Germany,undefined
[6] Department of Neuroradiology,undefined
[7] Institute of Diagnostic Radiology,undefined
[8] Klinikum Grosshadern,undefined
[9] University of Munich,undefined
[10] D-81366 Munich,undefined
[11] Germany,undefined
[12] Institute for Medical Epidemiology,undefined
[13] Klinikum Grosshadern,undefined
[14] University of Munich,undefined
[15] D-81366 Munich,undefined
[16] Germany,undefined
[17] Department of Radiology,undefined
[18] Massachusetts General Hospital,undefined
[19] NMR Center,undefined
[20] 13th Street,undefined
[21] Bldg. 149,undefined
[22] Charlestown,undefined
[23] MA 02129,undefined
[24] USA,undefined
来源
European Radiology | 1999年 / 9卷
关键词
Key words: Magnetic resonance; Brain; Brain tumors; Echo planar imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate.
引用
收藏
页码:1392 / 1396
页数:4
相关论文
共 50 条
  • [41] Feasibility of high-resolution readout-segmented echo-planar imaging with simultaneous multislice imaging in assessing rectal cancer
    Hongyun Huang
    Mi Zhou
    Tong Gong
    Yuting Wang
    [J]. Abdominal Radiology, 2023, 48 : 2258 - 2269
  • [42] Cholesteatoma imaging using modified echo-planar diffusion-weighted magnetic resonance imaging
    Flook, E.
    Izzat, S.
    Ismail, A.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2011, 125 (01): : 10 - 12
  • [43] Intensity-Corrected Dual-Echo Echo-Planar Imaging (DE-EPI) for Improved Pediatric Brain Diffusion Imaging
    Yeom, Kristen W.
    Straka, Matus
    Iv, Michael
    Moseley, Michael E.
    Barnes, Patrick D.
    Skare, Stefan
    Holdsworth, Samantha J.
    [J]. PLOS ONE, 2015, 10 (06):
  • [44] 1.5 Tesla Magnetic Resonance Imaging Features of Canine Intracranial Intra-axial Hematomas
    Whitlock, James
    Holdsworth, Andrew
    Morales, Carles
    Garosi, Laurent
    Carrera, Ines
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2021, 8
  • [45] Magnetic Resonance Elastography of Intervertebral Discs: Spin-Echo Echo-Planar Imaging Sequence Validation
    Co, Megan
    Dong, Huiming
    Boulter, Daniel J.
    Nguyen, Xuan, V
    Khan, Safdar N.
    Raterman, Brian
    Klamer, Brett
    Kolipaka, Arunark
    Walter, Benjamin A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (06) : 1722 - 1732
  • [46] Self-navigated multishot echo-planar pulse sequence for high-resolution diffusion-weighted imaging
    Nunes, RG
    Jezzard, P
    Behrens, TEJ
    Clare, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1474 - 1478
  • [47] Factors Affecting Detection Power of Blood Oxygen-Level Dependent Signal in Resting-State Functional Magnetic Resonance Imaging Using High-Resolution Echo-Planar Imaging
    Caparelli, Elisabeth C.
    Ross, Thomas J.
    Gu, Hong
    Yang, Yihong
    [J]. BRAIN CONNECTIVITY, 2019, 9 (08) : 638 - 648
  • [48] In vivo visualisation of Gaviscon alginate rafts using echo-planar magnetic resonance imaging
    Marciani, L
    Little, SL
    Coleman, N
    Young, P
    Tyler, D
    Snee, J
    Jolliffe, IG
    Dettmar, PW
    Gowland, PA
    Spiller, RC
    [J]. GUT, 2001, 48 : A36 - A36
  • [49] Multilevel Modeling of Fetal and Placental Growth Using Echo-Planar Magnetic Resonance Imaging
    Keith R. Duncan
    Daljit S. Sahota
    Penny A. Gowland
    Rachel Moore
    Allan Chang
    Philip N. Baker
    Ian R. Johnson
    [J]. The Journal of the Society for Gynecologic Investigation: JSGI, 2001, 8 (5): : 285 - 290
  • [50] OBSERVATION OF CEREBROSPINAL-FLUID FLOW WITH ECHO-PLANAR MAGNETIC-RESONANCE-IMAGING
    STEHLING, MK
    FIRTH, JL
    WORTHINGTON, BS
    GUILFOYLE, DN
    ORDIDGE, RJ
    COXON, R
    BLAMIRE, AM
    GIBBS, P
    BULLOCK, P
    MANSFIELD, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (758): : 89 - 97