Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors

被引:0
|
作者
R. Brüning
K. Seelos
T. Yousry
J. Scheidler
H. Exner
U. Porn
M. Reiser
B. R. Rosen
机构
[1] Institute of Diagnostic Radiology,
[2] Klinikum Grosshadern,undefined
[3] University of Munich,undefined
[4] D-81366 Munich,undefined
[5] Germany,undefined
[6] Department of Neuroradiology,undefined
[7] Institute of Diagnostic Radiology,undefined
[8] Klinikum Grosshadern,undefined
[9] University of Munich,undefined
[10] D-81366 Munich,undefined
[11] Germany,undefined
[12] Institute for Medical Epidemiology,undefined
[13] Klinikum Grosshadern,undefined
[14] University of Munich,undefined
[15] D-81366 Munich,undefined
[16] Germany,undefined
[17] Department of Radiology,undefined
[18] Massachusetts General Hospital,undefined
[19] NMR Center,undefined
[20] 13th Street,undefined
[21] Bldg. 149,undefined
[22] Charlestown,undefined
[23] MA 02129,undefined
[24] USA,undefined
来源
European Radiology | 1999年 / 9卷
关键词
Key words: Magnetic resonance; Brain; Brain tumors; Echo planar imaging;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to assess the potential of high-speed interleaved echo-planar imaging (EPI) to achieve diagnostic image quality comparable to T2-weighted imaging in patients with brain tumors. Seventeen patients with intra-axial, supratentorial tumors (10 untreated gliomas, 7 radiated gliomas) were investigated on a 1.5-T scanner. The conventional scan (SE, TR/TE = 2200/80 ms, 18 slices) was acquired in 8 min, 4 s, and EPI (TR/TE = 3000/80 ms, 18 slices) was completed in 25 s. The films were compared in a blinded trail by three radiologists. On the general impression and anatomic display, both sequences were rated to be of similar quality. Artifacts were slightly more pronounced at the skull base and around surgical clips using EPI. Tumor delineation was nearly equivalent using EPI, compared with the T2-weighted sequence. Echo-planar imaging reached diagnostic quality in all patients. Interleaved high-resolution EPI yielded sufficient quality to depict intra-axial, supratentorial brain tumors. Since EPI can be obtained in a small fraction of the time needed for conventional spin echo, in addition to other indications it could be considered to study patients unable to cooperate.
引用
收藏
页码:1392 / 1396
页数:4
相关论文
共 50 条
  • [1] Echo-planar magnetic resonance imaging (EPI) with high-resolution matrix in intra-axial brain tumors
    Brüning, R
    Seelos, K
    Yousry, T
    Scheidler, J
    Exner, H
    Porn, U
    Reiser, M
    Rosen, BR
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (07) : 1392 - 1396
  • [2] High-resolution echo-planar imaging of the brain: Is it suitable for routine clinical imaging?
    Ozdoba, C
    Remonda, L
    Heid, O
    Lovblad, KO
    Schroth, G
    [J]. NEURORADIOLOGY, 1997, 39 (12) : 833 - 840
  • [3] High-resolution echo-planar imaging of the brain: is it suitable for routine clinical imaging?
    C. Ozdoba
    L. Remonda
    O. Heid
    K.-O. Lövblad
    G. Schroth
    [J]. Neuroradiology, 1997, 39 : 833 - 840
  • [4] Clinical relevance of diffusion and perfusion magnetic resonance imaging in assessing intra-axial brain tumors
    N. Rollin
    J. Guyotat
    N. Streichenberger
    J. Honnorat
    V.-A. Tran Minh
    F. Cotton
    [J]. Neuroradiology, 2006, 48 : 150 - 159
  • [5] High-Resolution Echo-Planar Spectroscopic Imaging of the Human Calf
    Weis, Jan
    Bruvold, Morten
    Ortiz-Nieto, Francisco
    Ahlstrom, Hakan
    [J]. PLOS ONE, 2014, 9 (01):
  • [6] TECHNIQUES FOR HIGH-RESOLUTION ECHO-PLANAR MR IMAGING OF THE PANCREAS
    REIMER, P
    SAINI, S
    HAHN, PF
    MUELLER, PR
    BRADY, TJ
    COHEN, MS
    [J]. RADIOLOGY, 1992, 182 (01) : 175 - 179
  • [7] Clinical relevance of diffusion and perfusion magnetic resonance imaging in assessing intra-axial brain tumors
    Rollin, N
    Guyotat, J
    Streichenberger, N
    Honnorat, J
    Minh, VAT
    Cotton, F
    [J]. NEURORADIOLOGY, 2006, 48 (03) : 150 - 159
  • [8] Comparison of high-resolution echo-planar spectroscopic imaging with conventional MR imaging of prostate tumors in mice
    Du, WL
    Fan, XB
    Foxley, S
    Zamora, M
    River, JN
    Culp, RM
    Karczmar, GS
    [J]. NMR IN BIOMEDICINE, 2005, 18 (05) : 285 - 292
  • [9] Anatomical and functional brain imaging using high-resolution echo-planar spectroscopic imaging at 1.5 Tesla
    Du, WL
    Karczmar, GS
    Uftring, SJ
    Du, YPP
    [J]. NMR IN BIOMEDICINE, 2005, 18 (04) : 235 - 241
  • [10] High-resolution echo-planar spectroscopic imaging at ultra-high field
    Coello, Eduardo
    Noeske, Ralph
    Burns, Brian L.
    Gordon, Jeremy W.
    Jakary, Angela
    Menze, Bjoern
    Haase, Axel
    Larson, Peder E. Z.
    Li, Yan
    Schulte, Rolf F.
    [J]. NMR IN BIOMEDICINE, 2018, 31 (11)