Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST

被引:0
|
作者
Li Yang
Hong-Rui Cao
Jin-Long Zhao
Zi-Han Zhang
Qiang Li
Guo-Bin Wu
Yong-Qiang Zhang
Guo-Qiang Zhong
Li-Qun Hu
Zi-Jun Zhang
机构
[1] Chinese Academy of Sciences,Institute of Plasma Physics, Hefei Institutes of Physical Science
[2] University of Science and Technology of China,undefined
[3] Hefei University of Technology,undefined
来源
关键词
EAST; Neutron flux monitoring; High time resolution; Wide range; Pulse signal acquisition and processing system;
D O I
暂无
中图分类号
学科分类号
摘要
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak (EAST). The measurement result of neutron flux monitoring (NFM) is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity. Therefore, a wide range and high time resolution are required for the NFM system on EAST. To satisfy these requirements, a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed. The present study was conducted using a field-programmable gate array (FPGA) and peripheral component interconnect extension for instrument express (PXIe) platform. The digital dual measurement modes, which are composed of the pulse-counting mode and AC coupled square integral’s Campbelling mode, were designed to expand the measurement range of the signal acquisition and processing system. The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing high-speed analog-to-digital converters (ADCs), a high-speed PXIe communication with a direct memory access (DMA) mode, and online data preprocessing technology of FPGA. The signal acquisition and processing system was tested experimentally in the EAST radiation field. The test results showed that the time resolution of NFM was improved to 1 ms, and the dynamic range of the neutron counts rate was expanded to more than 106\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$10^{6}$$\end{document} counts per second. The Campbelling mode was calibrated using a multipoint average linear fitting method; subsequently, the fitting coefficient reached 0.9911. Therefore, the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
引用
收藏
相关论文
共 24 条
  • [1] Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST
    Li Yang
    Hong-Rui Cao
    Jin-Long Zhao
    Zi-Han Zhang
    Qiang Li
    Guo-Bin Wu
    Yong-Qiang Zhang
    Guo-Qiang Zhong
    Li-Qun Hu
    Zi-Jun Zhang
    NuclearScienceandTechniques, 2022, 33 (03) : 128 - 138
  • [2] Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST
    Yang, Li
    Cao, Hong-Rui
    Zhao, Jin-Long
    Zhang, Zi-Han
    Li, Qiang
    Wu, Guo-Bin
    Zhang, Yong-Qiang
    Zhong, Guo-Qiang
    Hu, Li-Qun
    Zhang, Zi-Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (03)
  • [3] Development of a wide-range neutron flux monitoring system in EAST
    Zhong, G. Q.
    Li, K.
    Hu, L. Q.
    Cao, H. R.
    Zhou, R. J.
    Lin, S. Y.
    Hong, B.
    Huo, Z. P.
    Zhang, H.
    Xiao, M.
    Zhou, M. J.
    Zhang, R. X.
    Huang, L. S.
    Huang, J.
    Fan, T. S.
    Zhang, Y. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05)
  • [4] NEW WIDE-RANGE FAST-RESPONSE ANALOG MEASUREMENT OF FREQUENCY
    CHO, GH
    SHIN, DH
    ELECTRONICS LETTERS, 1985, 21 (22) : 1034 - 1036
  • [5] NEW WIDE-RANGE FAST-RESPONSE ANALOGUE MEASUREMENT OF FREQUENCY.
    Gyu Hyeong Cho
    Dong Hee Shin
    1600, (21):
  • [6] FBR WIDE-RANGE NEUTRON MONITORING-SYSTEM
    TAI, I
    SEKI, E
    SAKAMOTO, M
    SAKUMA, T
    TOSHIBA REVIEW, 1983, (143): : 11 - 13
  • [7] FAST-RESPONSE SYSTEM FOR SIGNAL ACQUISITION AND PROCESSING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    ALLEN, E
    JACKSON, KW
    ANALYTICA CHIMICA ACTA, 1987, 192 (02) : 355 - 359
  • [8] OPTIMIZATION OF THE CABLING SYSTEM FOR A NEUTRON-FLUX WIDE-RANGE CHANNEL
    KLAR, E
    RACHOW, T
    ATOMKERNENERGIE-KERNTECHNIK, 1984, 44 (02): : 161 - 162
  • [9] DEVELOPMENT OF WIDE-RANGE NEUTRON MONITORING-SYSTEM USING FILTERS AT PREAMPLIFIER INPUT STAGE
    SHIRAYAMA, S
    SEKI, E
    TAI, I
    ENDO, Y
    ITO, T
    SATO, M
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1992, 34 (08): : 754 - 762
  • [10] Development of a high-speed digital pulse signal acquisition and processing system based on MTCA for liquid scintillator neutron detector on EAST
    Zhang, Yong-Qiang
    Hu, Li-Qun
    Zhong, Guo-Qiang
    Cao, Hong-Rui
    Zhao, Jin-Long
    Yang, Li
    Li, Qiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (10)