Performance of TES X-ray Microcalorimeters with a Novel Absorber Design

被引:0
|
作者
S. R. Bandler
R. P. Brekosky
A.-D. Brown
J. A. Chervenak
E. Figueroa-Feliciano
F. M. Finkbeiner
N. Iyomoto
R. L. Kelley
C. A. Kilbourne
F. S. Porter
J. Sadleir
S. J. Smith
机构
[1] NASA/Goddard Space Flight Center,Kavli Institute
[2] MIT,undefined
来源
关键词
Microcalorimeters; Transition edge sensors; 07.85.Nc; 29.40.Vj;
D O I
暂无
中图分类号
学科分类号
摘要
Superconducting transition-edge sensor (TES) microcalorimeters have demonstrated the Constellation-X requirements for spectral resolution, speed, and pixel size in a close-packed geometry. We will present our recent breakthrough energy resolution with sensors that have all gold and bismuth-gold absorbers. This has been enabled by cantilevered absorbers that make contact to the TES only in regions that are not part of the active thermometer. With this approach, rapid thermalization of the x-ray energy is achieved and interaction between the absorber and TES sensor films is avoided. This design allows us to obtain uniform high performance and is compatible with large-format, high fill-factor arrays. We will discuss this design, the results we have achieved in 8×8 arrays of these pixels, and the dependence of the performance on the geometry of the absorber contact area and on stress within the sensor.
引用
收藏
页码:400 / 405
页数:5
相关论文
共 50 条
  • [41] High count-rate study of two TES x-ray microcalorimeters with different transition temperatures
    Lee, Sang-Jun
    Adams, Joseph S.
    Bandler, Simon R.
    Betancourt-Martinez, Gabriele L.
    Chervenak, James A.
    Eckart, Megan E.
    Finkbeiner, Fred M.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sadleir, John E.
    Smith, Stephen J.
    Wassell, Edward J.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2017, 30 (10):
  • [42] Development of TES microcalorimeters for future X-ray missions - art. no. 62662M
    Ferrari, L.
    Dussoni, S.
    Gatti, F.
    Pergolesi, D.
    Gomes, M. Ribeiro
    Valle, R.
    Piro, L.
    Colasanti, L.
    Toniolo, M. Ferrari
    Torrioli, G.
    Bastia, P.
    Space Telescopes and Instrumentation II: Ultraviolet to Gamma Ray, Pts 1 and 2, 2006, 6266 : M2662 - M2662
  • [43] Cryogenic microcalorimeters for x-ray microanalysis
    Wollman, DA
    Hilton, GC
    Irwin, KD
    Bergren, NF
    Rudman, DA
    Newbury, DE
    Martinis, JM
    METROLOGY - AT THE THRESHOLD OF THE CENTURY ARE WE READY?, 1999, : 811 - 819
  • [44] Development of a Real-Time Pulse Processing Algorithm for TES-Based X-Ray Microcalorimeters
    Tan, Hui
    Hennig, Wolfgang
    Warburton, William K.
    Doriese, W. Bertrand
    Kilbourne, Caroline A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 276 - 280
  • [45] High resolution X-ray microcalorimeters
    Porter, FS
    Kelley, RL
    Kilbourne, CA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 436 - 438
  • [46] DEVELOPMENT OF X-RAY SILICON MICROCALORIMETERS
    Agnese, P.
    Aliane, A.
    Gasse, A.
    Demoro, F.
    Gobil, Y.
    Ballerand, S.
    Beccia, C.
    Borel, I.
    Goupy, J.
    Ribot, H.
    Pigot, C.
    Sauvageot, J. -L.
    Szeflinski, V.
    Perot, F.
    Gremion, E.
    de la Brose, X.
    Navick, X-F.
    ASTROPHYSICS DETECTOR WORKSHOP 2008, 2009, 37 : 89 - 93
  • [47] Energy Calibration of High-Resolution X-Ray TES Microcalorimeters With 3 eV Optical Photons
    Jaeckel, F. T.
    Ambarish, C., V
    Christensen, N.
    Gruenke, R.
    Hu, L.
    McCammon, D.
    McPheron, M.
    Meyer, M.
    Nelms, K. L.
    Roy, A.
    Wulf, D.
    Zhang, S.
    Zhou, Y.
    Adams, J. S.
    Bandler, S. R.
    Chervenak, J. A.
    Datesman, A. M.
    Eckart, M. E.
    Ewin, A. J.
    Finkbeiner, F. M.
    Kelley, R.
    Kilbourne, C. A.
    Miniussi, A. R.
    Porter, F. S.
    Sadleir, J. E.
    Sakai, K.
    Smith, S. J.
    Wakeham, N.
    Wassell, E.
    Yoon, W.
    Morgan, K. M.
    Schmidt, D. R.
    Swetz, D. S.
    Ullom, J. N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [48] Performance of Mo/Au TES microcalorimeters
    Lindeman, MA
    Brekosky, RP
    Figueroa-Feliciano, E
    Finkbeiner, FM
    Li, M
    Stahle, CK
    Stahle, CM
    Tralshawala, N
    LOW TEMPERATURE DETECTORS, 2002, 605 : 203 - 206
  • [49] Energy dispersive X-ray spectroscopy with microcalorimeters
    Hollerith, C
    Wernicke, D
    Bühler, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 606 - 609
  • [50] Fabrication of multi-pixel TES microcalorimeters with an electrodeposited Sn absorber and Bi absorber
    Arakawa, T
    Kudo, H
    Sato, H
    Kobayashi, H
    Izumi, T
    Ohtsuka, S
    Mori, K
    Shoji, S
    Osaka, T
    Homma, T
    Mitsuda, K
    Yamasaki, N
    Fujimoto, R
    Iyomoto, N
    Oshima, T
    Futamoto, K
    Takei, Y
    Ichitsubo, T
    Fujimori, T
    Yoshida, K
    Ishisaki, Y
    Morita, U
    Koga, T
    Shinozaki, K
    Sato, K
    Takai, N
    Ohashi, T
    Kuroda, Y
    Onishi, M
    Goto, M
    Beppu, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 456 - 459