Combined Fourier-transform infrared imaging and desorption electrospray-ionization linear ion-trap mass spectrometry for analysis of counterfeit antimalarial tablets

被引:0
|
作者
Camilla Ricci
Leonard Nyadong
Facundo M. Fernandez
Paul N. Newton
Sergei G. Kazarian
机构
[1] Imperial College London,Department of Chemical Engineering
[2] Georgia Institute of Technology,School of Chemistry and Biochemistry
[3] Mahosot Hospital,Wellcome Trust
[4] Oxford University,Mahosot Hospital
来源
关键词
Fake drugs; Malaria; Chemical imaging; Mass spectrometry; Forensic; Artesunate;
D O I
暂无
中图分类号
学科分类号
摘要
This paper reports use of a combination of Fourier-transform infrared (FTIR) spectroscopic imaging and desorption electrospray ionization linear ion-trap mass spectrometry (DESI MS) for characterization of counterfeit pharmaceutical tablets. The counterfeit artesunate antimalarial tablets were analyzed by both techniques. The results obtained revealed the ability of FTIR imaging in non-destructive micro-attenuated total reflection (ATR) mode to detect the distribution of all components in the tablet, the identities of which were confirmed by DESI MS. Chemical images of the tablets were obtained with high spatial resolution. The FTIR spectroscopic imaging method affords inherent chemical specificity with rapid acquisition of data. DESI MS enables high-sensitivity detection of trace organic compounds. Combination of these two orthogonal surface-characterization methods has great potential for detection and analysis of counterfeit tablets in the open air and without sample preparation.
引用
收藏
页码:551 / 559
页数:8
相关论文
共 50 条
  • [21] Structural Characterization of Unsaturated Glycerophospholipids by Multiple-Stage Linear Ion-Trap Mass Spectrometry with Electrospray Ionization
    Hsu, Fong-Fu
    Turk, John
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (11) : 1681 - 1691
  • [22] Direct analysis of microcystins by microbore liquid chromatography electrospray ionization ion-trap tandem mass spectrometry
    Zweigenbaum, JA
    Henion, JD
    Beattie, KA
    Codd, GA
    Poon, GK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (04) : 723 - 733
  • [23] ELECTRON-BEAM POTENTIAL DEPRESSION AS AN ION-TRAP IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY
    HENDRICKSON, CL
    HADJARAB, F
    LAUDE, DA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 141 (02): : 161 - 170
  • [24] Identification of Glycoside Compounds from Tobacco by High Performance Liquid Chromatography/Electrospray Ionization Linear Ion-Trap Tandem Mass Spectrometry Coupled with Electrospray Ionization Orbitrap Mass Spectrometry
    Jia, Chunxiao
    Zhu, Yonghua
    Zhang, Jinjie
    Yang, Jing
    Xu, Chunping
    Mao, Duobin
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (04) : 629 - 640
  • [25] EXPERIMENTAL-MEASUREMENT OF COULOMB ENERGY AND INTRINSIC DIELECTRIC POLARIZABILITY OF A MULTIPLY PROTONATED PEPTIDE ION USING ELECTROSPRAY-IONIZATION FOURIER-TRANSFORM MASS-SPECTROMETRY
    GROSS, DS
    WILLIAMS, ER
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1995, 117 (03) : 883 - 890
  • [26] Salvation of acylium fragment ions in electrospray ionization quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry
    Guan, ZQ
    Liesch, JM
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (03): : 264 - 276
  • [27] Use of electrospray ionization ion-trap tandem mass spectrometry and principal component analysis to directly distinguish monosaccharides
    Xia, Bing
    Zhou, Yan
    Liu, Xin
    Xiao, Juan
    Liu, Qing
    Gu, Yucheng
    Ding, Lisheng
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (11) : 1259 - 1264
  • [28] Establishing the occurrence of major and minor glucosinolates in Brassicaceae by LC-ESI-hybrid linear ion-trap and Fourier-transform ion cyclotron resonance mass spectrometry
    Lelario, Filomena
    Bianco, Giuliana
    Bufo, Sabino A.
    Cataldi, Tommaso R. I.
    PHYTOCHEMISTRY, 2012, 73 : 74 - 83
  • [29] Laser-induced acoustic desorption/chemical ionization in Fourier-transform ion cyclotron resonance mass spectrometry
    Pérez, J
    Ramírez-Arizmendi, LE
    Petzold, CJ
    Guler, LP
    Nelson, ED
    Kenttämaa, HI
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 198 (03) : 173 - 188
  • [30] SELECTED-ION ACCUMULATION FROM AN EXTERNAL ELECTROSPRAY-IONIZATION SOURCE WITH A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER
    BRUCE, JE
    ANDERSON, GA
    HOFSTADLER, SA
    VANORDEN, SL
    SHERMAN, MS
    ROCKWOOD, AL
    SMITH, RD
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) : 914 - 919