Determination of aortic pulse transit time based on waveform decomposition of radial pressure wave

被引:0
|
作者
Wenyan Liu
Daiyuan Song
Yang Yao
Lin Qi
Liling Hao
Jun Yang
Hongxia Ning
Lisheng Xu
机构
[1] Northeastern University,College of Medicine and Biological Information Engineering
[2] The First Hospital of China Medical University,undefined
[3] Key Laboratory of Medical Image Computing,undefined
[4] Ministry of Education,undefined
[5] Neusoft Research of Intelligent Healthcare Technology,undefined
[6] Co. Ltd.,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Carotid-femoral pulse transit time (cfPTT) is a widely accepted measure of central arterial stiffness. The cfPTT is commonly calculated from two synchronized pressure waves. However, measurement of synchronized pressure waves is technically challenging. In this paper, a method of decomposing the radial pressure wave is proposed for estimating cfPTT. From the radial pressure wave alone, the pressure wave can be decomposed into forward and backward waves by fitting a double triangular flow wave. The first zero point of the second derivative of the radial pressure wave and the peak of the dicrotic segment of radial pressure wave are used as the peaks of the fitted double triangular flow wave. The correlation coefficient between the measured wave and the estimated forward and backward waves based on the decomposition of the radial pressure wave was 0.98 and 0.75, respectively. Then from the backward wave, cfPTT can be estimated. Because it has been verified that the time lag estimation based on of backward wave has strong correlation with the measured cfPTT. The corresponding regression function between the time lag estimation of backward wave and measured cfPTT is y = 0.96x + 5.50 (r = 0.77; p < 0.001). The estimated cfPTT using radial pressure wave decomposition based on the proposed double triangular flow wave is more accurate and convenient than the decomposition of the aortic pressure wave based on the triangular flow wave. The significance of this study is that arterial stiffness can be directly estimated from a noninvasively measured radial pressure wave.
引用
下载
收藏
相关论文
共 50 条
  • [41] A LabVIEW based measure system for pulse wave transit time
    Zhang, J. A.
    Wei, P. F.
    Li, Y.
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 294 - +
  • [42] Determining arterial wave transit time from a single aortic pressure pulse in rats: vascular impulse response analysis
    Chang, Ru-Wen
    Chang, Chun-Yi
    Lai, Liang-Chuan
    Wu, Ming-Shiou
    Young, Tai-Horng
    Chen, Yih-Sharng
    Wang, Chih-Hsien
    Chang, Kuo-Chu
    SCIENTIFIC REPORTS, 2017, 7
  • [43] Determining arterial wave transit time from a single aortic pressure pulse in rats: vascular impulse response analysis
    Ru-Wen Chang
    Chun-Yi Chang
    Liang-Chuan Lai
    Ming-Shiou Wu
    Tai-Horng Young
    Yih-Sharng Chen
    Chih-Hsien Wang
    Kuo-Chu Chang
    Scientific Reports, 7
  • [44] Pulse transit time detection based on waveform time domain feature and dynamic difference threshold
    Chen, Ji (chenji@cqu.edu.cn), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [45] Cardiac Output Monitoring by Long Time Interval Analysis of a Radial Arterial Blood Pressure Waveform with Correction for Arterial Compliance Changes using Pulse Transit Time
    Moslehpour, Mohsen
    Zhang, Guanqun
    Mukkamala, Ramakrishna
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5496 - 5498
  • [46] Velocity estimation of aortic propagation based on radial pulse wave analysis
    Clara, Fernando
    Blanco, Gustavo
    Casarini, Alfredo
    Corral, Pablo
    Meschino, Gustavo
    Scandurra, Adriana
    MEDICINA-BUENOS AIRES, 2011, 71 (03) : 231 - 237
  • [47] Blood Pressure Estimation Based on Pulse Transit Time with LANDMARC
    Wang, Yang
    Liu, Zhiwen
    2017 IEEE LIFE SCIENCES CONFERENCE (LSC), 2017, : 141 - 144
  • [48] Aortic pulse wave velocity assessment in CMR: a novel method for transit time estimation
    Antonella Meloni
    Heather M Zmyewski
    Alessia Pepe
    Massimo Lombardi
    John C Wood
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [49] Radial pulse transit time is an index of arterial stiffness
    Zhang, Yong-Liang
    Zheng, Ying-Ying
    Ma, Zu-Chang
    Sun, Yi-Ning
    HYPERTENSION RESEARCH, 2011, 34 (07) : 884 - 887
  • [50] Radial pulse transit time is an index of arterial stiffness
    Yong-Liang Zhang
    Ying-Ying Zheng
    Zu-Chang Ma
    Yi-Ning Sun
    Hypertension Research, 2011, 34 : 884 - 887