Determination of aortic pulse transit time based on waveform decomposition of radial pressure wave

被引:0
|
作者
Wenyan Liu
Daiyuan Song
Yang Yao
Lin Qi
Liling Hao
Jun Yang
Hongxia Ning
Lisheng Xu
机构
[1] Northeastern University,College of Medicine and Biological Information Engineering
[2] The First Hospital of China Medical University,undefined
[3] Key Laboratory of Medical Image Computing,undefined
[4] Ministry of Education,undefined
[5] Neusoft Research of Intelligent Healthcare Technology,undefined
[6] Co. Ltd.,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Carotid-femoral pulse transit time (cfPTT) is a widely accepted measure of central arterial stiffness. The cfPTT is commonly calculated from two synchronized pressure waves. However, measurement of synchronized pressure waves is technically challenging. In this paper, a method of decomposing the radial pressure wave is proposed for estimating cfPTT. From the radial pressure wave alone, the pressure wave can be decomposed into forward and backward waves by fitting a double triangular flow wave. The first zero point of the second derivative of the radial pressure wave and the peak of the dicrotic segment of radial pressure wave are used as the peaks of the fitted double triangular flow wave. The correlation coefficient between the measured wave and the estimated forward and backward waves based on the decomposition of the radial pressure wave was 0.98 and 0.75, respectively. Then from the backward wave, cfPTT can be estimated. Because it has been verified that the time lag estimation based on of backward wave has strong correlation with the measured cfPTT. The corresponding regression function between the time lag estimation of backward wave and measured cfPTT is y = 0.96x + 5.50 (r = 0.77; p < 0.001). The estimated cfPTT using radial pressure wave decomposition based on the proposed double triangular flow wave is more accurate and convenient than the decomposition of the aortic pressure wave based on the triangular flow wave. The significance of this study is that arterial stiffness can be directly estimated from a noninvasively measured radial pressure wave.
引用
收藏
相关论文
共 50 条
  • [1] Determination of aortic pulse transit time based on waveform decomposition of radial pressure wave
    Liu, Wenyan
    Song, Daiyuan
    Yao, Yang
    Qi, Lin
    Hao, Liling
    Yang, Jun
    Ning, Hongxia
    Xu, Lisheng
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Determination of pulse transit time from waveform decomposition of the derived central aortic pressure pulse
    Qasem, A.
    Avolio, A.
    [J]. JOURNAL OF HYPERTENSION, 2006, 24 : S356 - S356
  • [3] Determination of aortic pulse wave velocity from waveform decomposition of the central aortic pressure pulse
    Qasem, Ahmed
    Avolio, Alberto
    [J]. HYPERTENSION, 2008, 51 (02) : 188 - 195
  • [4] Estimation of aortic pulse wave velocity based on waveform decomposition of central aortic pressure waveform
    Liu, Wenyan
    Yao, Yang
    Yang, Jinzhong
    Song, Daiyuan
    Zhang, Yuelan
    Sun, Guozhe
    Xu, Lisheng
    Avolio, Alberto
    [J]. PHYSIOLOGICAL MEASUREMENT, 2021, 42 (10)
  • [5] Calculation of aortic pulse wave velocity from waveform decomposition of the central aortic pressure pulse
    Qasem, A.
    Avolio, A.
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S284 - S284
  • [6] Determination of central aortic systolic and pulse pressure from the radial artery pressure waveform
    Adji, A
    O'Rourke, MF
    [J]. BLOOD PRESSURE MONITORING, 2004, 9 (03) : 115 - 121
  • [8] Estimation of Pulse Transit Time From Radial Pressure Waveform Alone by Artificial Neural Network
    Xiao, Hanguang
    Butlin, Mark
    Tan, Isabella
    Qasem, Ahmad
    Avolio, Alberto P.
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1140 - 1147
  • [9] Pulse waveform as an indicator of baseline offset in pulse transit time based blood pressure estimation
    Lin, Chen
    Zhou, Yuan
    Wang, Hu
    Wang, Yao
    [J]. 2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 26 - 31
  • [10] USING FLOW WAVEFORM APPROXIMATIONS FOR AORTIC WAVE REFLECTION AND PULSE TRANSIT TIME ASSESSMENT: A CRITICAL EVALUATION
    Kips, Jan G.
    Rietzschel, Ernst R.
    De Buyzere, Marc L.
    Gillebert, Thierry C.
    Van Bortel, Luc M.
    Segers, Patrick
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 421 - 422