Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws

被引:0
|
作者
Markus Beck
Robert Rotter
Georg Gradl
Philipp Herlyn
Markus Kröber
Thomas Mittlmeier
Philip Gierer
机构
[1] St. Bernward Krankenhaus,Department of Trauma and Orthopedic Surgery
[2] University of Rostock,Department of Trauma and Reconstructive Surgery
[3] Klinik St. Anna,Spinecenter
关键词
Intraoperative three dimensional imaging; 3D image intensifier; Thoracic spine; Pedicle screw; Reliability; Imaging studies;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1371 / 1377
页数:6
相关论文
共 50 条
  • [1] Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws
    Beck, Markus
    Rotter, Robert
    Gradl, Georg
    Herlyn, Philipp
    Kroeber, Markus
    Mittlmeier, Thomas
    Gierer, Philip
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (10) : 1371 - 1377
  • [2] Anterolateral thoracic approach for thoracic discectomy using pedicle marking and 3D intraoperative imaging system
    Alcachupas, Aljeirou
    Srikandarajah, Nisaharan
    Carleton-Bland, Nicholas
    Clark, Simon
    [J]. BRITISH JOURNAL OF NEUROSURGERY, 2024, 38 (04) : 995 - 997
  • [3] Placement of thoracic transvertebral pedicle screws using 3D image guidance
    Nottmeier, Eric W.
    Pirris, Stephen M.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2013, 18 (05) : 479 - 483
  • [4] Using a 3D Navigation Template to Increase the Accuracy of Thoracic Pedicle Screws in Patients with Scoliosis
    Jiang, Cheng-Hao
    Shi, Yan
    Sun, Yong-Mei
    Cai, Ming-Jun
    Wu, Hai-Long
    Hu, Li-Sheng
    Yu, Li-Min
    Wang, Peng
    Shen, Jie
    Huang, Yong-Can
    Yu, Bin-Sheng
    [J]. BIOENGINEERING-BASEL, 2023, 10 (07):
  • [5] Is intraoperative 3-D Imaging without Navigation sufficiently secure for the Placement of cervical Pedicle Screws?
    Barann, Bastian
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2018, 156 (06): : 630 - 630
  • [6] Intraoperative 3D Imaging: Value and Consequences in 248 Cases
    Kendoff, Daniel
    Citak, Musa
    Gardner, Michael J.
    Stuebig, Timo
    Krettek, Christian
    Huefner, Tobias
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (01): : 232 - 238
  • [7] Intraoperative 3D imaging with cone-beam computed tomography leads to revision of pedicle screws in dorsal instrumentation: a retrospective analysis
    Felix Zimmermann
    Katharina Kohl
    Maxim Privalov
    Jochen Franke
    Sven Y. Vetter
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [8] Intraoperative 3D imaging with cone-beam computed tomography leads to revision of pedicle screws in dorsal instrumentation: a retrospective analysis
    Zimmermann, Felix
    Kohl, Katharina
    Privalov, Maxim
    Franke, Jochen
    Vetter, Sven Y.
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [9] Reliability of an Intraoperative Radiographic Anteroposterior View of the Spinal Midline for Detection of Pedicle Screws Breaching the Medial Pedicle Wall in the Thoracic, Lumbar, and Sacral Spine
    Maejima, Ryuya
    Takeuchi, Mikinobu
    Wakao, Norimitsu
    Kamiya, Mitsuhiro
    Aoyama, Masahiro
    Joko, Masahiro
    Osuka, Koji
    Takayasu, Masakazu
    [J]. WORLD NEUROSURGERY, 2019, 125 : E257 - E261
  • [10] C-OnSite® for intraoperative 3D control of pedicular screw positions
    Sven Rainer Kantelhardt
    Naureen Keric
    Jens Conrad
    Amr Nimer
    Raymund Woo
    Laura Varich
    Alf Giese
    [J]. Acta Neurochirurgica, 2014, 156 : 1799 - 1805