Intraoperative 3D Imaging: Value and Consequences in 248 Cases

被引:67
|
作者
Kendoff, Daniel [1 ]
Citak, Musa [1 ]
Gardner, Michael J. [2 ]
Stuebig, Timo [1 ]
Krettek, Christian [1 ]
Huefner, Tobias [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
[2] Hosp Special Surg, Dept Orthopaed Surg, New York, NY 10021 USA
关键词
Intraoperative imaging; 3-D imaging; Intraarticular fractures; Fracture reduction; Implant placement; MOBILE C-ARM; INTRAARTICULAR CALCANEAL FRACTURES; COMPUTED-TOMOGRAPHY; PLAIN RADIOGRAPHY; SIEMENS ISO-C-3D; CLASSIFICATION; RECONSTRUCTION; DISPLACEMENT; MANAGEMENT; REDUCTION;
D O I
10.1097/TA.0b013e31815ede5d
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Intraoperative visualization of articular surfaces is technically demanding, and standard two-dimensional fluoroscopic imaging frequently does not provide adequate detail of nonplanar joints. New imaging modalities allow for intraoperative 3D visualization, which are useful in articular fractures. Purpose of this study was to evaluate the utility of 3D imaging in articular fracture reconstruction. Methods: in a prospective cohort study, we evaluated 248 consecutive patients with intra-articular fractures. After fracture fixation using standard fluoroscopy, 3D imaging was performed intraoperatively using the Iso-C3D system for all patients, Surgeons filled out questionnaires regarding the utility and perceived accuracy of the 3D system. Postoperative CT scans were performed on approximately half of the patients. Main outcome measurements were based on the surgeons decision to immediately revise the articular reduction or implant position. The setup time for the system was recorded. For patients with postoperative CT scans, articular surface gaps of 2 mm or intra-articular hardware placement was again evaluated. Results: In 19% of all cases, intraoperative image analysis resulted in immediate adjustment of the reduction or hardware exchange. These revisions were based on Iso-C3D views of the articular surface that were not visible using fluoroscopy. Of the 129 postoperative CT scans, five cases revealed a technical error of the joint reconstruction, and a secondary revision procedure was performed. Conclusion: In conclusion, the IsoC3D was a valuable intraoperative tool, providing additional information about the articular surface compared with conventional fluoroscopy in a variety of anatomic regions.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [1] Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws
    Beck, Markus
    Rotter, Robert
    Gradl, Georg
    Herlyn, Philipp
    Kroeber, Markus
    Mittlmeier, Thomas
    Gierer, Philip
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (10) : 1371 - 1377
  • [2] Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws
    Markus Beck
    Robert Rotter
    Georg Gradl
    Philipp Herlyn
    Markus Kröber
    Thomas Mittlmeier
    Philip Gierer
    [J]. Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 1371 - 1377
  • [3] Intraoperative 3D imaging in spinal surgery
    Gonschorek, O.
    Hauck, S.
    Buehren, V.
    [J]. UNFALLCHIRURG, 2016, 119 (10): : 817 - 824
  • [4] Intraoperative imaging with the ISO C 3D [Intraoperative bildgebung mit dem ISO C 3D]
    Wich M.
    Spranger N.
    Ekkernkamp A.
    [J]. Der Chirurg, 2004, 75 (10): : 982 - 987
  • [5] Intraoperative 3D imaging in the treatment of elbow fractures - a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases
    Marc Schnetzke
    Julia Fuchs
    Sven Y. Vetter
    Nils Beisemann
    Holger Keil
    Paul-Alfred Grützner
    Jochen Franke
    [J]. BMC Medical Imaging, 16
  • [6] Intraoperative 3D imaging in the treatment of elbow fractures - a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases
    Schnetzke, Marc
    Fuchs, Julia
    Vetter, Sven Y.
    Beisemann, Nils
    Keil, Holger
    Gruetzner, Paul-Alfred
    Franke, Jochen
    [J]. BMC MEDICAL IMAGING, 2016, 16
  • [7] Snapping scapula: value of 3D imaging
    Sans, N
    Jarlaud, T
    Sarrouy, P
    Globbini, K
    Bellumore, Y
    Railhac, JJ
    [J]. JOURNAL DE RADIOLOGIE, 1999, 80 (04): : 379 - 381
  • [8] Role of 3D intraoperative imaging in orthopedic and trauma surgery
    Tonetti, Jerome
    Boudissa, Mehdi
    Kerschbaumer, Gael
    Seurat, Olivier
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (01) : S19 - S25
  • [9] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [10] Segmentation of brain tumour in 3D Intraoperative Ultrasound imaging
    Angel-Raya, Erick
    Chalopin, Claire
    Avina-Cervantes, Juan Gabriel
    Cruz-Aceves, Ivan
    Wein, Wolfgang
    Lindner, Dirk
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (06):