SiO2-modified carbon paste electrode for electrochemical determination of pyrogallol

被引:0
|
作者
J. Tashkhourian
S. M. Ghaderizadeh
机构
[1] Shiraz University,Department of Chemistry, College of Sciences
来源
关键词
silica; carbon paste electrode; differential pulse voltammetry; pyrogallol;
D O I
暂无
中图分类号
学科分类号
摘要
A silica gel-modified carbon paste electrode (Si-CPE) was fabricated and used for determination of pyrogallol. Cyclic and differential pulse voltammetric studies show that Si-CPE lowers oxidation potential remarkably increases its oxidation peak current and improves electrochemical behavior of pyrogallol, compared to unmodified CPE. The effects of pH value, amount of silica, accumulation potential and time on the oxidation peak current of pyrogallol were examined. As a result, a sensitive, rapid and convenient electroanalytical method was developed for pyrogallol. The linear range is from 2 to 300 μM, and the limit of detection is 0.7 μM after 4.0 min accumulation. Interferences from some inorganic salts and organic compounds were studied. Finally, the method was successfully used to determine pyrogallol in tap water, green tea and artificial urine samples
引用
收藏
页码:959 / 966
页数:7
相关论文
共 50 条
  • [1] SiO2-modified carbon paste electrode for electrochemical determination of pyrogallol
    Tashkhourian, J.
    Ghaderizadeh, S. M.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (10) : 959 - 966
  • [2] Application of mesoporous SiO2-Modified carbon paste electrode for voltammetric determination of epinephrine
    Yi, Hongchao
    Li, Zixian
    Li, Kehua
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (11) : 1073 - 1080
  • [3] Application of mesoporous SiO2-Modified carbon paste electrode for voltammetric determination of epinephrine
    Hongchao Yi
    Zixian Li
    Kehua Li
    Russian Journal of Electrochemistry, 2013, 49 : 1073 - 1080
  • [4] Electrochemical determination of uric acid using a mesoporous SiO2-modified electrode
    Yanhong Zeng
    Jiajia Xu
    Kangbing Wu
    Microchimica Acta, 2008, 161 : 249 - 253
  • [5] Electrochemical determination of uric acid using a mesoporous SiO2-modified electrode
    Zeng, Yanhong
    Xu, Jiajia
    Wu, Kangbing
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 249 - 253
  • [6] Preparation of an electrochemical sensor based on a HKUST-1/CoFe2O4/SiO2-modified carbon paste electrode for determination of azaperone
    Ghalkhani, Masoumeh
    Gharagozlou, Mehrnaz
    Sohouli, Esmail
    Khosrowshahi, Elnaz Marzi
    MICROCHEMICAL JOURNAL, 2022, 175
  • [7] Electrochemical determination of 5-hydroxytryptamine using mesoporous SiO2 modified carbon paste electrode
    Jinchun Song
    Ji Yang
    Xiangliang Yang
    Russian Journal of Electrochemistry, 2009, 45 : 1346 - 1350
  • [8] Electrochemical Determination of 5-Hydroxytryptamine Using Mesoporous SiO2 Modified Carbon Paste Electrode
    Song, Jinchun
    Yang, Ji
    Yang, Xiangliang
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2009, 45 (12) : 1346 - 1350
  • [9] A sensitive electrochemical sensor for determination of gallic acid based on SiO2 nanoparticle modified carbon paste electrode
    Tashkhourian, J.
    Nami-Ana, S. F.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 : 103 - 110
  • [10] Determination of traces of copper by adsorptive stripping voltammetry with pyrogallol red modified carbon paste electrode
    Guo, H.S.
    Li, Y.H.
    2001, Shanghai Research Institute of Materials (37):