Photo-responsivity characterizations of CdTe films for direct-conversion X-ray detectors

被引:0
|
作者
Ryun Kyung Kim
Bo Kyung Cha
Sungchae Jeon
Chang-Woo Seo
Seungman Yun
机构
[1] Korea Electrotechnology Research Institute,School of Mechanical Engineering
[2] Pusan National University,undefined
来源
Journal of the Korean Physical Society | 2014年 / 65卷
关键词
Cadmium telluride; Photoconductor; Direct-conversion X-ray detector; 29.90.+r; 06.90.+v; 41.50.+h;
D O I
暂无
中图分类号
学科分类号
摘要
We have fabricated and investigated thin, polycrystalline, cadmium-telluride (CdTe) films in order to utilize them for optical switching readout layers in direct-conversion X-ray detectors. The polycrystalline CdTe films are fabricated on ITO glasses by using the physical vapor deposition (PVD) method at a slow deposition rate and a pressure of 10−6 torr. CdTe films with thicknesses of 5 and 20 μm are grown. The electrical and the optical characteristics of the CdTe films are investigated by measuring the dark-current and the photo-current as functions of the applied field under different wavelengths of light. Higher photo-currents are generated at the longer wavelengths of light for the same applied voltage. When a higher electrical field is applied to the 20 μm-thick CdTe film, a higher dark-current, a higher photo-current, a larger number of charges, and a higher quantum efficiency are generated.
引用
收藏
页码:446 / 449
页数:3
相关论文
共 50 条
  • [31] EVALUATION OF K X-RAY ESCAPE AND CROSSTALK IN CDTE DETECTORS AND MULTICHANNEL DETECTORS
    OHTSUCHI, T
    OHMORI, K
    TSUTSUI, H
    BABA, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (03) : 179 - 184
  • [32] FAST PHOTOCONDUCTOR CDTE DETECTORS FOR SYNCHROTRON X-RAY STUDIES
    YOO, SS
    WANG, KM
    MONTANO, PA
    FAURIE, JP
    HUANG, Q
    RODRICKS, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 527 - 530
  • [33] INVESTIGATION OF CDTE DETECTORS DESIGNED FOR COMPUTER X-RAY TOMOGRAPHY
    KARPENKO, VP
    MATVEEV, OA
    SEMICONDUCTORS, 1993, 27 (11-12) : 1048 - 1050
  • [34] Spectral correction algorithm for multispectral CdTe X-ray detectors
    Christensen, Erik D.
    Kehres, Jan
    Gu, Yun
    Feidenhans'l, Robert
    Olsen, Ulrik L.
    RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393
  • [35] CdTe X-ray detectors under strong optical irradiation
    Cola, Adriano
    Farella, Isabella
    APPLIED PHYSICS LETTERS, 2014, 105 (20)
  • [36] Spectral correction algorithm for multispectral CdTe x-ray detectors
    Dreier, Erik Schou
    Kehres, Jan
    Khalil, Mohamad
    Busi, Matteo
    Gu, Yun
    Feidenhans'l, Robert
    Olsen, Ulrik Lund
    OPTICAL ENGINEERING, 2018, 57 (05)
  • [37] Study of CdTe and CdZnTe detectors for X-ray computed tomography
    Ricq, S
    Glasser, F
    Garcin, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 534 - 543
  • [38] Use of Monte Carlo method to evaluate the response of direct conversion X-ray detectors
    Gui Jian-Bao
    Guo Jin-Chuan
    Yang Qin-Lao
    Niu Han-Ben
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (10): : 933 - 937
  • [39] Screening effects in high resistivity CdTe for X-ray and gamma ray detectors
    Kubat, J.
    Franc, J.
    Grill, R.
    Horodysky, P.
    Hlidek, P.
    Belas, E.
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 871 - 876
  • [40] Screening Effects in High Resistivity CdTe for X-ray and Gamma Ray Detectors
    J. Kubát
    J. Franc
    R. Grill
    P. Horodyský
    P. Hlídek
    E. Belas
    Journal of Electronic Materials, 2007, 36 : 871 - 876