Parathyroid 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double-phase washout

被引:0
|
作者
William D. Leslie
Jacqueline O. Dupont
Bohdan Bybel
Karl T. Riese
机构
[1] Section of Nuclear Medicine,
[2] University of Manitoba and St. Boniface General Hospital,undefined
[3] Winnipeg,undefined
[4] Canada,undefined
[5] Department of Surgery,undefined
[6] St. Boniface General Hospital,undefined
[7] Winnipeg,undefined
[8] Canada,undefined
[9] Correspondence to: Department of Medicine (C5121),undefined
[10] University of Manitoba and St. Boniface General Hospital,undefined
[11] 409 Tache Avenue,undefined
[12] Winnipeg,undefined
[13] Canada R2H 2A6,undefined
[14] e-mail: bleslie@sbgh.mb.ca,undefined
[15] Tel.: +1-204-2372311,undefined
[16] Fax: +1-204-2337154,undefined
关键词
Hyperparathyroidism Parathyroid Adenoma Sestamibi;
D O I
暂无
中图分类号
学科分类号
摘要
Technetium-99m sestamibi imaging for parathyroid adenoma localization has been performed using both dual-tracer subtraction and double-phase single-tracer washout techniques. The relative accuracy of these two techniques is uncertain. We have developed a modified imaging technique which combines both approaches and have directly compared them in a series of patients with surgically explored hyperparathyroidism. Initial injection of 99mTc-pertechnetate 50 MBq was followed by continuous dynamic imaging of the anterior neck for 30 min. 99mTc-sestamibi 1,000 MBq was injected intravenously at the midpoint of the acquisition. Delayed images were performed after 2 h. We blindly reviewed 88 consecutive cases of surgically explored hyperparathyroidism that had undergone preoperative scintigraphic localization with this procedure. Images were reformatted to display subtraction-only, early/delayed sestamibi-only and combined images. Scans were reviewed in random order. Of the 68 cases with solitary parathyroid adenoma, the sestamibi-only images gave correct localization in 49 (72%) while there was a statistically significant improvement in accuracy using the subtraction-only images (58 of 68, 85%, P=0.05) and the combined images (61 of 68, 90%, P=0.0015). Reader confidence was also greater with the subtraction-only and combined images than with the sestamibi-only images. Scan performance with parathyroid hyperplasia was less satisfactory. Although the largest gland was usually correctly identified, hyperplasia was difficult to distinguish from a solitary adenoma. Dual-tracer subtraction parathyroid imaging is superior to double-phase sestamibi-only imaging. The washout data may provide additional information in some cases, however, and an approach that combines both techniques may be optimal.
引用
收藏
页码:1566 / 1570
页数:4
相关论文
共 50 条
  • [31] Scintigraphy of the parathyroid glands with 99mTc-sestamibi in three dogs with primary hyperparathyroidism
    Kreissl, Hannah
    Mathes, Andrea
    Neiger, Reto
    KLEINTIERPRAXIS, 2015, 60 (02): : 57 - +
  • [32] Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase 99mTc-Sestamibi parathyroid scintigraphy
    Lavely, William C.
    Goetze, Sibyll
    Friedman, Kent P.
    Leal, Jeffrey P.
    Zhang, Zhe
    Garret-Mayer, Elizabeth
    Dackiw, Alan P.
    Tufano, Ralph P.
    Zeiger, Martha A.
    Ziessman, Harvey A.
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) : 1084 - 1089
  • [33] LOCALIZATION OF AN ECTOPIC PARATHYROID ADENOMA BY DOUBLE-PHASE TECHNETIUM-99M-SESTAMIBI SCINTIGRAPHY
    CARAVALHO, J
    BALINGIT, AG
    RIVERARODRIGUEZ, JE
    SHRIVER, CD
    KOOPS, MK
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (10) : 1840 - 1842
  • [34] Double-phase scintigraphy at 99m Tc MIBI or dual scintigraphy at 99mTc/99mTc MIBI for the diagnosis of associated parathyroid or thyroid pathologies?
    Stefanescu, C.
    Rusu, V.
    Rusu, M.
    Vulpoi, C.
    Mogos, V.
    Zbranca, E.
    DIABETES & METABOLISM, 2007, 33 : S139 - S139
  • [35] The Performance of Dual-phase 99mTc-sestamibi Parathyroid SPECT/CT in Primary Hyperparathyroidism
    Quak, E.
    Ciappuccini, R.
    Nganoa, C. A.
    Aide, N.
    Heutte, N.
    Blanchard, D.
    Rame, J.
    Bardet, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S569 - S569
  • [36] 99mTcO4-/99mTc-MIBI dual-tracer scintigraphy for preoperative localization of parathyroid adenomas
    Huang, Zhongke
    Lou, Cen
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 836 - 845
  • [37] Focal Pulmonary Uptake on 99mTc-Sestamibi Parathyroid Scintigraphy Due to Iatrogenic Microembolism
    Kou, Ying
    Shen, Guohua
    Ou, Xiaohong
    Huang, Rui
    Kuang, Anren
    CLINICAL NUCLEAR MEDICINE, 2018, 43 (01) : 33 - 35
  • [38] Performance of 99mTc-Sestamibi parathyroid scintigraphy in secondary hyperparathyroidism (about 20 cases)
    Amouri, W.
    Kallel, F.
    Hamza, F.
    Jardak, I.
    Charfeddine, S.
    Ghorbel, A.
    Guermazi, F.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (10-11): : 420 - 428
  • [39] Effect of Pgp and MRP expression on detection of parathyroid tumors by 99mTc-Sestamibi scintigraphy
    Jorna, FH
    Hollema, H
    Que, L
    Jager, PL
    Piers, DA
    Plukker, JT
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (02) : S120 - S120
  • [40] Assessment of preoperative 99mTc-Sestamibi scintigraphy in video-assisted parathyroid surgery
    Toubeau, M
    Blanc-Bernard, E
    Berriolo, A
    Thomas, C
    Touzery, C
    Cougard, P
    Brunotte, F
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1090 - 1090