BioFlow: a non-invasive, image-based method to measure speed, pressure and forces inside living cells

被引:0
|
作者
Aleix Boquet-Pujadas
Timothée Lecomte
Maria Manich
Roman Thibeaux
Elisabeth Labruyère
Nancy Guillén
Jean-Christophe Olivo-Marin
Alexandre C. Dufour
机构
[1] Institut Pasteur,
[2] Bioimage Analysis Unit,undefined
[3] CNRS UMR3691,undefined
[4] Institut Pasteur,undefined
[5] Cell Biology of Parasitism Unit,undefined
[6] INSERM U786,undefined
[7] Institut Pasteur,undefined
[8] CNRS ERL9195,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Cell motility is governed by a complex molecular machinery that converts physico-chemical cues into whole-cell movement. Understanding the underlying biophysical mechanisms requires the ability to measure physical quantities inside the cell in a simple, reproducible and preferably non-invasive manner. To this end, we developed BioFlow, a computational mechano-imaging method and associated software able to extract intracellular measurements including pressure, forces and velocity everywhere inside freely moving cells in two and three dimensions with high spatial resolution in a non-invasive manner. This is achieved by extracting the motion of intracellular material observed using fluorescence microscopy, while simultaneously inferring the parameters of a given theoretical model of the cell interior. We illustrate the power of BioFlow in the context of amoeboid cell migration, by modelling the intracellular actin bulk flow of the parasite Entamoeba histolytica using fluid dynamics, and report unique experimental measures that complement and extend both theoretical estimations and invasive experimental measures. Thanks to its flexibility, BioFlow is easily adaptable to other theoretical models of the cell, and alleviates the need for complex or invasive experimental conditions, thus constituting a powerful tool-kit for mechano-biology studies. BioFlow is open-source and freely available via the Icy software.
引用
收藏
相关论文
共 50 条
  • [31] Image-based non-contact method to measure cross-sectional areas and shapes of tendons and ligaments
    Salisbury, S. T. Samuel
    Buckley, C. Paul
    Zavatsky, Amy B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (04)
  • [32] Validation of a Non-Invasive OCT-based Method to Measure Ocular Rigidity using Intravitreal Injections of Bevacizumab
    Sayah, Diane N.
    Descovich, Denise
    Mazzaferri, Javier
    Duval, Renaud
    Rezende, Flavio
    Costantino, Santiago
    Lesk, Mark R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [33] 2D image-based crack monitoring: an affordable, sufficient and non-invasive technique for the democratization of preventive conservation of listed buildings
    Jesús Oliveros-Esco
    Luis Gracia-Villa
    Belinda López-Mesa
    Heritage Science, 10
  • [34] 2D image-based crack monitoring: an affordable, sufficient and non-invasive technique for the democratization of preventive conservation of listed buildings
    Oliveros-Esco, Jesus
    Gracia-Villa, Luis
    Lopez-Mesa, Belinda
    HERITAGE SCIENCE, 2022, 10 (01)
  • [35] An Ultrasound-Based Non-Invasive Blood Pressure Estimation Method Based on Optimal Vascular Wall Tracking Position
    Liu, Liyuan
    Geng, Xingguang
    Yao, Fei
    Zhang, Yitao
    Zhang, Haiying
    Wang, Yunfeng
    Zheng, Zhaoying
    IEEE ACCESS, 2025, 13 : 17132 - 17149
  • [36] Electrical Bio-Impedance based non-invasive method for the central aortic blood pressure waveform estimation
    Krivoshei, Andrei
    Min, Mart
    Uuetoa, Hasso
    Lamp, Jurgen
    Annus, Paul
    2014 PROCEEDINGS OF THE 14TH BIENNIAL BALTIC ELECTRONICS CONFERENCE (BEC 2014), 2014, : 181 - 184
  • [37] A novel method for non-invasive blood pressure estimation based on continuous pulse transit time: An observational study
    Shin, Hangsik
    PSYCHOPHYSIOLOGY, 2023, 60 (02)
  • [38] A new non-invasive device for measuring instantaneous blood pressure in radial artery based on the volume-compensation method
    Tanaka, S
    Gao, S
    Nogawa, M
    Yamakoshi, K
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3149 - 3152
  • [39] Non-invasive continuous blood pressure monitoring method based on GA-MIV-BP neural network model
    Tan X.
    Ji Z.
    Zhang Y.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (09): : 71 - 79
  • [40] Evaluation Of A Non-invasive Left Ventricular Pressure-volume Loop Approximation Method Based On Arterial Blood Pressure Values And Cardiac MRI
    Liu, Jing
    Pahlevan, Niema M.
    CIRCULATION, 2021, 144