Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw

被引:16
|
作者
Salari P. [1 ]
Moed B.R. [1 ,2 ]
Bledsoe J.G. [1 ,2 ]
机构
[1] Department of Orthopaedic Surgery, Saint Louis University School of Medicine, 3635 Vista Avenue, 7th Floor Desloge Towers, St. Louis, 63110, MO
[2] Department of Biomedical Engineering, Parks College of Engineering, Aviation and Technology, Saint Louis University, 3450 Lindell Boulevard, St. Louis, 63103, MO
关键词
Iliosacral screws; Transsacral screws; Type C pelvic ring injuries;
D O I
10.1007/s10195-015-0357-8
中图分类号
学科分类号
摘要
Background: A single iliosacral screw placed into the S1 vertebral body has been shown to be clinically unreliable for certain type C pelvic ring injuries. Insertion of a second supplemental iliosacral screw into the S1 or S2 vertebral body has been widely used. However, clinical fixation failures have been reported using this technique, and a supplemental long iliosacral or transsacral screw has been used. The purpose of this study was to compare the biomechanical effect of a supplemental S1 long iliosacral screw versus a transsacral screw in an unstable type C vertically oriented sacral fracture model. Materials and methods: A type C pelvic ring injury was created in ten osteopenic/osteoporotic cadaver pelves by performing vertical osteotomies through zone 2 of the sacrum and the ipsilateral pubic rami. The sacrum was reduced maintaining a 2-mm fracture gap to simulate a closed-reduction model. All specimens were fixed using one 7.0-mm iliosacral screw into the S1 body. A supplemental long iliosacral screw was placed into the S1 body in five specimens. A supplemental transsacral S1 screw was placed in the other five. Each pelvis underwent 100,000 cycles at 250 N, followed by loading to failure. Vertical displacements at 25,000, 50,000, 75,000, and 100,000 cycles and failure force were recorded. Results: Vertical displacement increased significantly (p < 0.05) within each group with each increase in the number of cycles. However, there was no statistically significant difference between groups in displacement or load to failure. Conclusions: Although intuitively a transsacral screw may seem to be better than a long iliosacral screw in conveying additional stability to an unstable sacral fracture fixation construct, we were not able to identify any biomechanical advantage of one method over the other. Level of evidence: Does not apply—biomechanical study. © 2015, The Author(s).
引用
收藏
页码:293 / 300
页数:7
相关论文
共 50 条
  • [41] Type C pelvic ring injuries in polytrauma patients: can percutaneous iliosacral screws reduce morbidity and costs?
    Mostafa A. Ayoub
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 137 - 144
  • [42] Type C pelvic ring injuries in polytrauma patients: can percutaneous iliosacral screws reduce morbidity and costs?
    Ayoub, Mostafa A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (02): : 137 - 144
  • [43] A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury
    Chen, Hongfen
    Ding, Chao
    Liu, Yongqiang
    Kong, Zhen
    Chang, Siling
    Huang, Feng
    Li, Heng
    Guo, Qingxiang
    Yang, Yuehua
    Zhong, Hua
    Yang, Shaozheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [44] A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury
    Hongfen Chen
    Chao Ding
    Yongqiang Liu
    Zhen Kong
    Siling Chang
    Feng Huang
    Heng Li
    Qingxiang Guo
    Yuehua Yang
    Hua Zhong
    Shaozheng Yang
    Journal of Orthopaedic Surgery and Research, 17
  • [45] Biomechanical investigation of S2 alar-iliac screw and S1 pedicle screw fixation in the treatment of Denis type II sacral fractures
    Zheng, Jianxiong
    Liu, Fei
    Xiang, Jie
    Leung, Frankie K. L.
    Feng, Xiaoreng
    Chen, Bin
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2023, 41 (01) : 215 - 224
  • [46] Do we need another screw? Sacroiliac screw fixation in open-book pelvic ring injuries (APC type II)
    Jordan, Martin C.
    Fuchs, Konrad F.
    Herath, Steven C.
    Windolf, Joachim
    Meffert, Rainer H.
    Neubert, Anne
    EFORT OPEN REVIEWS, 2024, 9 (08) : 827 - 836
  • [47] Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
    Jui-Ping Chen
    Ping-Jui Tsai
    Chun-Yi Su
    I.-Chuan Tseng
    Ying-Chao Chou
    I.-Jung Chen
    Pai-Wei Lee
    Yi-Hsun Yu
    Scientific Reports, 12
  • [48] Percutaneous iliosacral screw and trans-iliac trans-sacral screw with single C-arm fluoroscope intensifier is a safe treatment for pelvic ring injuries
    Chen, Jui-Ping
    Tsai, Ping-Jui
    Su, Chun-Yi
    Tseng, I. -Chuan
    Chou, Ying-Chao
    Chen, I. -Jung
    Lee, Pai-Wei
    Yu, Yi-Hsun
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [49] Modified pedicle screw-rod fixation versus anterior pelvic external fixation for the management of anterior pelvic ring fractures: a comparative study
    Chun Bi
    Qiugen Wang
    Jianhong Wu
    Feng Zhou
    Fei Zhang
    Haipeng Liang
    Fei Lyu
    Jiandong Wang
    Journal of Orthopaedic Surgery and Research, 12
  • [50] Modified pedicle screw-rod fixation versus anterior pelvic external fixation for the management of anterior pelvic ring fractures: a comparative study
    Bi, Chun
    Wang, Qiugen
    Wu, Jianhong
    Zhou, Feng
    Zhang, Fei
    Liang, Haipeng
    Lyu, Fei
    Wang, Jiandong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12