Electrooxidative behavior and determination of trifluoperazine at multiwalled carbon nanotube-modified glassy carbon electrode

被引:0
|
作者
Burcu Dogan-Topal
机构
[1] Ankara University,Faculty of Pharmacy, Department of Analytical Chemistry
关键词
Trifluoperazine; Carbon nanotubes; Voltammetry; Modified glassy carbon electrode; Pharmaceuticals;
D O I
暂无
中图分类号
学科分类号
摘要
The mechanism of electrochemical oxidation of trifluoperazine has been proposed on the basis of cyclic and differential pulse voltammetry at a multiwalled carbon nanotube-modified glassy carbon electrode. The modified electrode exhibits catalytic activity, high sensitivity, and stability. The oxidation process exhibited an adsorption-controlled behavior. Also, depending on this adsorption control, a sensitive electroanalytical method for the determination of trifluoperazine has been investigated by adsorptive stripping differential pulse voltammetry. Under the optional conditions, the anodic peak current was linear to the trifluoperazine concentration over the range of 2.08 10−8 M to 1.67 10−6 M, and the limit of detection was 7.49 10−10 M. The modified electrode had good stability and repeatability, and it was successfully applied to the determination of trifluoperazine in pharmaceuticals.
引用
收藏
页码:1059 / 1066
页数:7
相关论文
共 50 条
  • [31] Gold nanoparticle/double-walled carbon nanotube-modified glassy carbon electrode and its application
    Song, Y. Z.
    Song, Y.
    Zhong, H.
    [J]. GOLD BULLETIN, 2011, 44 (02) : 107 - 111
  • [32] The electrochemical behavior of dopamine at glassy carbon electrode modified by Nafion multiwalled carbon nanotubes
    Yuanzhi Song
    Yang Song
    Wen Xie
    Deqing Shi
    [J]. Russian Journal of Physical Chemistry, 2006, 80 : 1467 - 1474
  • [33] The electrochemical behavior of dopamine at glassy carbon electrode modified by Nafion multiwalled carbon nanotubes
    Song, Yuanzhi
    Song, Yang
    Xie, Wen
    Shi, Deqing
    [J]. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2006, 80 (09): : 1467 - 1474
  • [34] A Mexacarbate Electrochemical Biosensor on Carbon Materials Based on a Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Tharini, J.
    Chen, Tse-Wei
    Chen, Shen-Ming
    Saraswathi, R.
    Elshikh, Mohamed S.
    Darwish, Noura M.
    Rwei, Syang-Peng
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (08): : 8311 - 8325
  • [35] Electrochemical Determination and In Silico Studies of Fludarabine on NH2 Functionalized Multiwalled Carbon Nanotube Modified Glassy Carbon Electrode
    Dogan-Topal, Burcu
    Bakirhan, Nurgul K.
    Tok, Tugba Taskin
    Ozkan, Sibel A.
    [J]. ELECTROANALYSIS, 2020, 32 (01) : 37 - 49
  • [36] Electrochemical sensor using glassy carbon electrode modified with acylpyrazolone-multiwalled carbon nanotube composite film for determination of xanthine
    Song, Yun
    Li, Jinzhou
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (02) : 689 - 695
  • [37] Simultaneous Voltammetric Determination of Theophylline and Guaifenesin Using a Multiwalled Carbon Nanotube-Ionic Liquid Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Khodadadian, Mehdi
    [J]. ELECTROANALYSIS, 2014, 26 (09) : 1975 - 1983
  • [38] Amperometric determination of ascorbic acid using multiwalled carbon nanotube-thiolated polyaniline composite modified glassy carbon electrode
    Liu, Ying
    Su, Zhaohong
    Zhang, Yi
    Chen, Li
    Gu, Tiean
    Huang, Siyu
    Liu, Yan
    Sun, Lingen
    Xie, Qingji
    Yao, Shouzhuo
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 709 : 19 - 25
  • [39] Electrochemical sensor using glassy carbon electrode modified with acylpyrazolone-multiwalled carbon nanotube composite film for determination of xanthine
    Yun Song
    Jinzhou Li
    [J]. Journal of Solid State Electrochemistry, 2012, 16 : 689 - 695
  • [40] Voltammetric determination of cefpirome at multiwalled carbon nanotube modified glassy carbon sensor based electrode in bulk form and pharmaceutical formulation
    Jain, Rajeev
    Vikas
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 87 (02) : 423 - 426