Analyzing the influence of PEG molecular weight on the separation of PEGylated gold nanoparticles by asymmetric-flow field-flow fractionation

被引:0
|
作者
Matthew Hansen
Mackensie C. Smith
Rachael M. Crist
Jeffrey D. Clogston
Scott E. McNeil
机构
[1] Frederick National Laboratory for Cancer Research,Nanotechnology Characterization Laboratory, Cancer Research Technology Program, Leidos Biomedical Research, Inc.
来源
关键词
Polyethylene glycol; Surface characterization; Asymmetric-flow field-flow fractionation; Gold nanoparticles; Separation;
D O I
暂无
中图分类号
学科分类号
摘要
Polyethylene glycol (PEG) is an important tool for increasing the biocompatibility of nanoparticle therapeutics. Understanding how these potential nanomedicines will react after they have been introduced into the bloodstream is a critical component of the preclinical evaluation process. Hence, it is paramount that better methods for separating, characterizing, and analyzing these complex and polydisperse formulations are developed. We present a method for separating nominal 30-nm gold nanoparticles coated with various molecular weight PEG moieties that uses only phosphate-buffered saline as the mobile phase, without the need for stabilizing surfactants. The optimized asymmetric-flow field-flow fractionation technique using in-line multiangle light scattering, dynamic light scattering, refractive index, and UV–vis detectors allowed successful separation and detection of a mixture of nanoparticles coated with 2-, 5-, 10-, and 20-kDa PEG. The particles coated with the larger PEG species (10 and 20 kDa) were eluted at times significantly earlier than predicted by field-flow fractionation theory. This was attributed to a lower-density PEG shell for the higher molecular weight PEGylated nanoparticles, which allows a more fluid PEG surface that can be greater influenced by external forces. Hence, the apparent particle hydrodynamic size may fluctuate significantly depending on the overall density of the stabilizing surface coating when an external force is applied. This has considerable implications for PEGylated nanoparticles intended for in vivo application, as nanoparticle size is important for determining circulation times, accumulation sites, and routes of excretion, and highlights the importance and value of the use of secondary size detectors when one is working with complex samples in asymmetric-flow field-flow fractionation.
引用
收藏
页码:8661 / 8672
页数:11
相关论文
共 50 条
  • [21] Asymmetric flow field-flow fractionation of superferrimagnetic iron oxide multicore nanoparticles
    Dutz, Silvio
    Kuntsche, Judith
    Eberbeck, Dietmar
    Mueller, Robert
    Zeisberger, Matthias
    NANOTECHNOLOGY, 2012, 23 (35)
  • [22] Observation of size-independent effects in nanoparticle retention behavior during asymmetric-flow field-flow fractionation
    Gigault, Julien
    Hackley, Vincent A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (19) : 6251 - 6258
  • [23] Observation of size-independent effects in nanoparticle retention behavior during asymmetric-flow field-flow fractionation
    Julien Gigault
    Vincent A. Hackley
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6251 - 6258
  • [24] Nanoparticles separation by different conditions at asymmetric flow field-flow fractionation (Vol 39, pg 500, 2023)
    Chiang, C. L.
    Yeh, J. A.
    Yeh, C. W.
    JOURNAL OF MECHANICS, 2024, 40 : 425 - 425
  • [25] SEPARATION OF CELLS BY FIELD-FLOW FRACTIONATION
    GIDDINGS, JC
    BARMAN, BN
    ZHANG, J
    LIU, MK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 47 - IAEC
  • [26] Asymmetric Flow Field-Flow Fractionation Investigation of Magnetopolyplexes
    Haladjova, Emi
    Rangelov, Stanislav
    Geisler, Martin
    Boye, Susanne
    Lederer, Albena
    Mountrichas, Grigoris
    Pispas, Stergios
    MACROMOLECULAR CHEMISTRY AND PHYSICS, 2015, 216 (18) : 1862 - 1867
  • [27] SEPARATION OF CELLS BY FIELD-FLOW FRACTIONATION
    GIDDINGS, JC
    BARMAN, BN
    LIU, MK
    ACS SYMPOSIUM SERIES, 1991, 464 : 128 - 144
  • [28] Influence of oscillating main flow on separation efficiency in asymmetrical flow field-flow fractionation
    Berger, Martin
    Scherer, Christian
    Noskov, Sergey
    Bantz, Christoph
    Nickel, Conrad
    Schupp, Wolfgang
    Maskos, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1640
  • [29] Asymmetric flow field-flow fractionation of liposomes: optimization of fractionation variables
    Hupfeld, Stefan
    Ausbacher, Dominik
    Brandl, Martin
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (09) : 1465 - 1470
  • [30] Asymmetric Flow Field-Flow Fractionation Analysis of Engineered Nanoparticles in Mouthwashes and Their Interaction with Saliva
    Krystek, Petra
    Spallek, Markus J.
    Klein, Thorsten
    de Boer, Jacob
    LC GC NORTH AMERICA, 2016, 34 (08) : 559 - 563