Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging device

被引:0
|
作者
Tejpal Gupta
Supriya Chopra
Avinash Kadam
Jai Prakash Agarwal
P Reena Devi
Sarbani Ghosh-Laskar
Ketayun Ardeshir Dinshaw
机构
[1] Education in Cancer (ACTREC),Department of Radiation Oncology
[2] Tata Memorial Centre,Department of Radiation Oncology
[3] Tata Memorial Hospital,undefined
来源
关键词
Clinical Target Volume; Portal Image; Electronic Portal Imaging Device; Neck Radiotherapy; Planning Target Volume Margin;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] SET-UP ERRORS IN HEAD-AND-NECK FRAMELESS STEREOTACTIC TREATMENTS: AN INVESTIGATION USING EXACTRAC
    Uttman, K.
    Jarlskog, C. Zacharatou
    Enmark, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S268 - S268
  • [32] The impact of reference isocentre position on set-up errors in head-and-neck image-guided radiotherapy
    Lenko, Helena
    Peterlin, Primoz
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 104 - 113
  • [33] Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer
    Dzierma, Yvonne
    Beyhs, Monica
    Palm, Jan
    Niewald, Marcus
    Bell, Katharina
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1055 - 1059
  • [34] Location Error of the Dens in a Two-Dimensional Set-up Verification During Head and Neck Radiotherapy
    Kim, Dong Hyun
    Kim, Won Taek
    Ki, Yong Gan
    Nam, Ji Ho
    Lee, Mi Ran
    Jeon, Ho Sang
    Park, Dal
    Kim, Dong Won
    [J]. RADIATION ONCOLOGY JOURNAL, 2011, 29 (02): : 107 - 114
  • [35] Image Guidance Derived Set-up Errors for Head and Neck IMRT Patients
    Richmond, N.
    Pilling, K.
    Thompson, E.
    Walker, C.
    Dunlop, P.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S50 - S51
  • [36] Comparison of set-up errors by breast size on wing board by portal imaging
    Raza, Waseem
    Agarwal, Sushma
    Das, Koilpillai Joseph Maria
    Kumar, Sellepolyam Kaliyaperumal Senthil
    Lal, Punita
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (05) : 447 - 452
  • [37] Assessment of set-up discrepancies using daily portal imaging during radiotherapy treatment for patients with spine and bone metastases
    Young, L.
    Blyth, C. M.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (04) : 209 - 216
  • [38] Comparison of geometric uncertainties using electronic portal imaging device in focal three-dimensional conformal radiation therapy using different head supports
    Budrukkar, Ashwini
    Dutta, Debnarayan
    Sharma, Dayanand
    Yadav, Premnath
    Dantas, Smitha
    Jalali, Rakesh
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (02) : 70 - 76
  • [39] Clinical Feasibility of Using an Electronic Portal Imaging Device for Position Verification during Conventional Radiotherapy
    Shen, Yuxiaotong
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Li, Haiwei
    Sun, Wei
    Ji, Mingxi
    Wei, Quanbo
    Cai, Jing
    Li, Bing
    [J]. 2016 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (NANOMED), 2016, : 99 - 103
  • [40] Evaluation of set up uncertainity in HNIMRT treatment using an electronic portal imaging device
    Vanoni, V.
    Delana, A.
    Menegotti, L.
    Ziglio, F.
    Bolner, A.
    Mussari, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S317 - S317