Micro-tip Cantilever as Low Frequency Microphone

被引:0
|
作者
Sumit Dass
Rajan Jha
机构
[1] Indian Institute of Technology Bhubaneswar,Nanophotonics and Plasmonics Laboratory, School of Basic Sciences
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
We propose a very compact diaphragm free optical microphone consisting a tapered micro-tip in cantilever configuration for detection of low frequency acoustic signals. The change in the light coupling between the micro-tip and the source fiber caused by the acoustic pressure is utilized to detect the external acoustic signal. The sensitivity and working range of the sensor depend on three key factors, the length of the micro-tip cantilever, the distance between the micro-tip and SMF, and the offset between the micro-tip central axis and SMF central axis. Hence, by changing any of these parameters, the performance of the sensor can be easily tuned. Experimental results show that for a cantilever length of 15 mm, the probe has a maximum acoustic sensitivity of 10.63 mV/Pa or −159.5 dB re 1 V/μPa, noise-limited minimum detectable pressure of 19.1 mPa/√Hz and the linear frequency range is 0–400 Hz. The SMF only structure along with photodetector-based interrogation makes this acoustic sensor economical.
引用
收藏
相关论文
共 50 条
  • [1] Micro-tip Cantilever as Low Frequency Microphone
    Dass, Sumit
    Jha, Rajan
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [2] Low Level Ionic Current Sensing Micro-tip
    Memon, Shahzad
    Balachandran, Wamadeva
    [J]. 2010 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2010,
  • [3] Broken micro-tip spinal needle
    Greenway, M. W.
    Vickers, R.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2009, 18 (03) : 295 - 296
  • [4] Fabrication of Micro-tip for Coupling to Wire Waveguides
    Tomiki, Masahiro
    Sakata, Hajime
    [J]. 2017 22ND MICROOPTICS CONFERENCE (MOC), 2017, : 274 - 275
  • [5] FABRICATION AND CHARACTERISTICS OF SILICON MICRO-TIP ARRAYS
    Chen, Kuan-Jen
    Fang, Te-Hua
    Ji, Liang-Wen
    Chang, Shoou-Jinn
    Young, Sheng-Joue
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2010, 24 (28): : 5601 - 5611
  • [6] A FIBEROPTIC MICRO-TIP PRESSURE TRANSDUCER FOR MEDICAL APPLICATIONS
    HANSEN, TE
    [J]. SENSORS AND ACTUATORS, 1983, 4 (04): : 545 - 554
  • [7] Fabrication of polymer micro-tip by optical lensing technique
    Dey, Pradip Kumar
    Das, Soumen
    Ganguly, Pranabendu
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2012, 18 (05): : 623 - 628
  • [8] Fabrication of polymer micro-tip by optical lensing technique
    Pradip Kumar Dey
    Soumen Das
    Pranabendu Ganguly
    [J]. Microsystem Technologies, 2012, 18 : 623 - 628
  • [9] Control of diamond micro-tip geometry for field emitter
    Baik, ES
    Baik, YJ
    Jeon, D
    [J]. THIN SOLID FILMS, 2000, 377 (377-378) : 299 - 302
  • [10] VESICAL INSTABILITY - URODYNAMIC PARAMETERS BY MICRO-TIP TRANSDUCER CATHETERS
    HEBERT, DB
    OSTERGARD, DR
    [J]. OBSTETRICS AND GYNECOLOGY, 1982, 60 (03): : 331 - 337