A microcantilever-based gas flow sensor for flow rate and direction detection

被引:0
|
作者
Rong-Hua Ma
Po-Cheng Chou
Yu-Hsiang Wang
Tzu-Han Hsueh
Lung-Ming Fu
Chia-Yen Lee
机构
[1] R.O.C. Military Academy,
[2] Shu-Te University,undefined
[3] Da-Yeh University,undefined
[4] National Pingtung University,undefined
来源
Microsystem Technologies | 2009年 / 15卷
关键词
Residual Stress; Cantilever Beam; Nitride Layer; Upward Direction; Flow Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Utilizing conventional micro-electro-mechanical systems techniques, this study fabricates and characterizes a novel micro gas flow sensor comprising four silicon nitride/silicon wafer cantilever beams arranged in a cross-form configuration. The residual stresses induced within the beams during their fabrication cause the tip of each beam to curve slightly in the upward direction. However, as air travels over the surface of the sensor, the upstream cantilevers are deflected in the downward direction, while the downstream cantilevers are deflected in the upward direction. The velocity of the air flow is then determined by measuring the corresponding change in resistance of the piezoresistors patterned on the upper surface of each cantilever beam. It is shown that by measuring the change in resistance of all four cantilever beams, the proposed sensor can detect not only the velocity of the air flow, but also its direction.
引用
收藏
页码:1201 / 1205
页数:4
相关论文
共 50 条
  • [21] Label free detection of vitamin D by microcantilever-based aptasensor
    Alzahrani, Khalid E.
    Al-Gawati, Mahmoud
    Assaifan, Abdulaziz K.
    Alodhayb, Abdullah
    Alotaibi, Khalid
    Alswieleh, Abdullah
    Albrithen, Hamad
    Alanazi, Amal F.
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2023, 35 (10)
  • [22] Resonance Frequency Change in Microcantilever-based Sensor due to Humidity Variation
    Nuryadi, Ratno
    Djajadi, Arko
    Adiel, Reyhan
    Aprilia, Lia
    Aisah, Nuning
    NANOTECHNOLOGY APPLICATIONS IN ENERGY AND ENVIRONMENT, 2013, 737 : 176 - +
  • [23] Inaccuracy in the detection of molecules using two microcantilever-based methods
    Luo, C
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2005, 72 (04): : 617 - 619
  • [24] A microcantilever-based alcohol vapor sensor-application and response model
    Jensenius, H
    Thaysen, J
    Rasmussen, AA
    Veje, LH
    Hansen, O
    Boisen, A
    APPLIED PHYSICS LETTERS, 2000, 76 (18) : 2615 - 2617
  • [25] Design and fabrication of a graphene-based microcantilever flow sensor for liquid flow measurement
    Shadmand, Zahra
    Shahrouzi, Javad Rahbar
    Chaboki, Hossein Hosseinzadeh
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 317
  • [26] Geometry optimization of uncoated silicon microcantilever-based gas density sensors
    Boudjiet, M. T.
    Bertrand, J.
    Mathieu, F.
    Nicu, L.
    Mazenq, L.
    Leichle, T.
    Heinrich, M.
    Pellet, C.
    Dufour, I.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 600 - 607
  • [27] A Carrier Gas Flow velocity and Flow Direction Sensor and Its Interface Circuit
    Liao, Honghua
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 542 - 549
  • [28] Induced Mass Change Technique for Glucose Detection in Microcantilever-based Sensors
    Nor, Mardhiah Mohd
    Bais, Badariah
    Abd Aziz, Norazreen
    Ab Rahim, Rosminazuin
    Majlis, Burhanuddin Yeop
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE), 2012, : 340 - 343
  • [29] 3,4-Methylenedioxymethylamphetamine detection using a microcantilever-based biosensor
    Tseng, You-Chen
    Chang, Jeng-Shian
    Lin, Shiming
    Chao, Sheng D.
    Liu, Chih-Hao
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 182 : 163 - 167
  • [30] Design and Modeling of a New MEMS Capacitive Microcantilever Sensor for Gas Flow Monitoring
    Panahi, Abbas
    Ghasemi, Pouya
    Sabour, Mohammad Hossein
    Magierowski, Sebastian
    Ghafar-Zadeh, Ebrahim
    IEEE CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2021, 44 (04): : 467 - 479