Research on roller monitoring technology based on distributed fiber optic sensing system

被引:3
|
作者
Xie, Miao [1 ]
Li, Bo [2 ]
Ma, Suning [1 ]
Lu, Jinnan [1 ]
Hu, Guilin [3 ]
Meng, Qingshuang [1 ]
Luo, Jiaxing [1 ]
机构
[1] Liaoning Tech Univ, Sch Mech Engn, Fuxin 123000, Peoples R China
[2] Liaoning Tech Univ, Fac Elect & Control Engn, Huludao 125105, Peoples R China
[3] Xinjiang Key Lab Intelligent Exploit & Control Op, Changji 831100, Peoples R China
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
中国国家自然科学基金;
关键词
D O I
10.1038/s41598-024-60884-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
As one of the key components of the belt conveyor, the roller bears the task of supporting and rolling the conveyor belt, and monitoring its condition is very important. The traditional monitoring of the conveyor roller group adopts worker inspection, which has strong subjectivity. Monitoring using sensors necessitates the use of numerous sensors, which can pose wiring challenges. The use of inspection robots for monitoring results can be discontinuous, and their performance may be limited. This study proposes a fault diagnosis method for rollers based on a distributed fiber optic sensing system. By improving the traditional Isolation Forest (IForest), a framework called Incremental Majority Voting Isolation Forest (IMV-IForest) is proposed. By analyzing the optical signal, we extracted the variation patterns of roller faults over time and space, and analyzed the abnormal score distribution between fault data and normal data. Using the dataset collected on-site, we compared and analyzed IMV-IForest with the traditional IForest and the Extended Isolation Forest (E-iForest). The results indicate that the variation of the fault of the faulty roller with time and space can be used for early prediction of roller faults; determine an anomaly score threshold of 0.6; improved IForest have faster computation time and higher accuracy. Finally, to verify the effectiveness of the proposed scheme, a 3-month experiment was conducted on a 600 m long belt conveyor in a certain mine, and on-site monitoring results were obtained. By comparing with manual detection results, it was shown that the proposed method has high recognition rate for faulty idlers, with an accuracy rate of 97.92%, and can effectively diagnose faulty idlers.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Multi-gas leakage synchronous monitoring system based on the distributed optical fiber sensing technology
    Cui, Lu-Jun
    Cao, Yan-Long
    Guo, Hong-Hong
    Guo, Shi-Rui
    Zeng, Wenhang
    Wang, Pei-Xiong
    Chen, Gang
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2022, 22 (02) : 615 - 621
  • [32] Raman distributed fiber optic sensing technology based on chaotic pulse clusters (invited)
    Cheng, Zijia
    Li, Jian
    Fan, Bowen
    Zhang, Weiyi
    Xue, Xiaohui
    Zhang, Mingjiang
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2024, 53 (10):
  • [33] Long-distance transmission conductor condition sensing based on distributed fiber optic sensing technology
    Jia, Boyan
    Wang, Yixin
    Pang, Xianhai
    Ding, Likun
    Sun, Cuiying
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2024,
  • [34] Research on distributed optical fiber sensing technology for power pipe corridor breakdown monitoring
    Fan J.
    Huang M.
    Wang Y.
    Yong M.
    Lü L.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (10): : 1433 - 1442
  • [35] Application research of distributed optical fiber sensing technology in nuclear island safety monitoring
    Li Ruiyan
    Yang Xiaojun
    Du Rui
    Kong Lingbing
    Pan Liang
    Mei Ying
    GLOBAL INTELLIGENT INDUSTRY CONFERENCE 2020, 2021, 11780
  • [36] Application research on hydraulic coke cutting monitoring system based on optical fiber sensing technology
    Zhong D.
    Tong X.
    Photonic Sensors, 2014, 4 (2) : 147 - 151
  • [37] Pipeline corrosion and leakage monitoring based on the distributed optical fiber sensing technology
    Ren, Liang
    Jiang, Tao
    Jia, Zi-guang
    Li, Dong-sheng
    Yuan, Chao-lin
    Li, Hong-nan
    MEASUREMENT, 2018, 122 : 57 - 65
  • [38] Fiber-optic distributed-temperature-sensing technology used for reservoir monitoring in an Indonesia steamflood
    Nath, D. K.
    Sugianto, Riki
    Finley, Doug
    SPE DRILLING & COMPLETION, 2007, 22 (02) : 149 - 156
  • [39] Research Progress of Applying Distributed Fiber Optic Measurement Technology in Hydraulic Fracturing and Production Monitoring
    Wang, Yilin
    Wu, Zhuoping
    Wang, Fuyong
    ENERGIES, 2022, 15 (20)
  • [40] Monitoring of Coal Waste Piles With Fiber Optic Sensing Technology
    Viveiros, D.
    Ribeiro, J.
    Ferreira, J.
    Pinto, A. M. R.
    Perez-Herrera, R. A.
    Diaz, S.
    Lopez-Gil, A.
    Dominguez-Lopez, A.
    Esteban, O.
    Martins, H. F.
    Martin-Lopez, S.
    Baierl, H.
    Auguste, J. -L.
    Jamier, R.
    Rougier, S.
    Santos, J. L.
    Flores, D.
    Roy, P.
    Gonzalez-Herraez, M.
    Lopez-Amo, M.
    Baptista, J. M.
    PROCEEDINGS OF 2015 3RD EXPERIMENT AT INTERNATIONAL CONFERENCE (EXP AT'15), 2015, : 147 - +