Investigation of leakage current and electric field of polymeric insulator with ring-shaped contamination under ice conditions

被引:0
|
作者
Zahra Ghiasi
Faramarz Faghihi
Amir Abbas Shayegani-Akmal
机构
[1] Islamic Azad University,Department of Electrical Engineering
[2] Science and Research Branch,High Voltage Laboratory
[3] University of Tehran,undefined
来源
Electrical Engineering | 2022年 / 104卷
关键词
Electric filed distribution; Leakage current; Polymeric insulator; Ice conditions; Ring-shaped contamination;
D O I
暂无
中图分类号
学科分类号
摘要
Different environmental conditions such as pollution, rain, and frost affect the performance of polymeric insulators. In cold climates, insulators may become frozen, resulting in non-uniform distribution of potential and electric field around the insulator. Non-uniform distribution of potential and electric field along the insulator in turn cause problems such as erosion and flashover. Also, due to the wind direction in cold regions, the pollution layer accumulates non-uniformity on the insulator surface. This paper investigated the effect of ice layer with different configurations in combination with ring-shaped contamination, which is more common in cold regions, on the insulator surface to obtain the electric field distribution and leakage current of a 20 kV polymeric insulator. For this purpose, software based on finite element method (FEM) was used. Experimental test for evaluating the leakage current analysis of ring-shaped polluted insulator under ice condition was done in a laboratory clean fog chamber. The results of experimental data and the proposed simulated models were compared and validated. The results revealed that parameters such as increasing the freezing layer and its intensity, continuity of the freezing structure and electrical conductivity of the ice layer would enhance the amplitude of the electric field and leakage current, increasing the probability of flashover. Also, in the combination of ring-shaped contamination layer and freezing, the parameters of the ice layer are more influential than the contamination layer on the electrical behavior of the insulator.
引用
收藏
页码:2079 / 2089
页数:10
相关论文
共 50 条
  • [41] Recurrent Plot for Leakage Current Investigation and Performance Monitoring of HV Insulator Model under Discontinuous Pollution
    Chaou, K. A.
    Mekhaldi, A.
    Teguar, M.
    2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [42] The impacts of electric and magnetic field on the binding energy of hydrogenic donor impurity in a InGaAsP/InP ring-shaped quantum well wire
    M. Hu
    H-L Wang
    Q. Gong
    S-M Wang
    Indian Journal of Physics, 2018, 92 : 1389 - 1395
  • [43] The impacts of electric and magnetic field on the binding energy of hydrogenic donor impurity in a InGaAsP/InP ring-shaped quantum well wire
    Hu, M.
    Wang, H-L
    Gong, Q.
    Wang, S-M
    INDIAN JOURNAL OF PHYSICS, 2018, 92 (11) : 1389 - 1395
  • [44] Comparison of leakage current properties between polymeric insulators and porcelain insulators under salt polluted conditions
    Homma, H
    Kuroyagi, T
    Ishino, R
    Takahashi, T
    PROCEEDINGS OF THE 2005 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, VOLS, 1-3, 2005, : 348 - 351
  • [45] Investigation of Electric Field Distribution on A C Composite 230kV Insulator Using Corona Ring
    Kalimurugan, M. S.
    Sankar, S. Arun
    Iruthayarajan, M. Willjuice
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 142 - 147
  • [46] Shallow-impurity-related binding energy and linear optical absorption in ring-shaped quantum dots and quantum-well wires under applied electric field
    Kohl, Simon A. A.
    Restrepo, R. L.
    Mora-Ramos, M. E.
    Duque, C. A.
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2015, 252 (04): : 786 - 794
  • [47] Evaluation of Electric Field Distribution on a 400 kV Composite Insulator under Various Service Conditions
    Bouhaouche, M.
    Mekhaldi, A.
    Teguar, M.
    2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 1003 - 1006
  • [48] Flashover Process and Frequency Analysis of the Leakage Current on Insulator Model under non-Uniform Pollution Conditions
    Douar, M. A.
    Mekhaldi, A.
    Bouzidi, M. C.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (04) : 1284 - 1297
  • [49] FEM analysis of electric field distribution for polymeric insulator under different configuration of non-uniform pollution
    Zahra Ghiasi
    Faramarz Faghihi
    Amir Abbas Shayegani-Akmal
    Hassan Moradi CheshmehBeigi
    Kumars Rouzbehi
    Electrical Engineering, 2021, 103 : 2799 - 2808
  • [50] FEM analysis of electric field distribution for polymeric insulator under different configuration of non-uniform pollution
    Ghiasi, Zahra
    Faghihi, Faramarz
    Shayegani-Akmal, Amir Abbas
    Moradi CheshmehBeigi, Hassan
    Rouzbehi, Kumars
    ELECTRICAL ENGINEERING, 2021, 103 (06) : 2799 - 2808