Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies

被引:0
|
作者
Taner Erselcan
Bulent Turgut
Derya Dogan
Semra Ozdemir
机构
[1] Department of Nuclear Medicine,
[2] Cumhuriyet University School of Medicine,undefined
[3] P.K. 806 Sivas,undefined
[4] Turkey,undefined
关键词
Lean body mass DEXA Standardized uptake value SUV PET;
D O I
暂无
中图分类号
学科分类号
摘要
The standardized uptake value (SUV) has gained recognition in recent years as a semiquantitative evaluation parameter in positron emission tomography (PET) studies. However, there is as yet no consensus on the way in which this index should be determined. One of the confusing factors is the normalisation procedure. Among the proposed anthropometric parameters for normalisation is lean body mass (LBM); LBM has been determined by using a predictive equation in most if not all of the studies. In the present study, we assessed the degree of agreement of various LBM predictive equations with a reference method. Secondly, we evaluated the impact of predicted LBM values on a hypothetical value of 2.5 SUV, normalised to LBM (SUVLBM), by using various equations. The study population consisted of 153 women, aged 32.3±11.8 years (mean±SD), with a height of 1.61±0.06 m, a weight of 71.1±17.5 kg, a body surface area of 1.77±0.22 m2 and a body mass index of 27.6±6.9 kg/m2. LBM (44.2±6.6 kg) was measured by a dual-energy X-ray absorptiometry (DEXA) method. A total of nine equations from the literature were evaluated, four of them from recent PET studies. Although there was significant correlation between predicted and measured LBM values, 95% limits of agreement determined by the Bland and Altman method showed a wide range of variation in predicted LBM values as compared with DEXA, no matter which predictive equation was used. Moreover, only one predictive equation was not statistically different in the comparison of means (DEXA and predicted LBM values). It was also shown that the predictive equations used in this study yield a wide range of SUVLBM values from 1.78 to 5.16 (29% less or 107% more) for an SUV of 2.5. In conclusion, this study suggests that estimation of LBM by use of a predictive equation may cause substantial error for an individual, and that if LBM is chosen for the SUV normalisation procedure, it should be measured, not predicted.
引用
收藏
页码:1630 / 1638
页数:8
相关论文
共 35 条
  • [1] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Erselcan, T
    Turgut, B
    Dogan, D
    Ozdemir, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (12) : 1630 - 1638
  • [2] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Taner Erselcan
    Bulent Turgut
    Derya Dogan
    Semra Ozdemir
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 936 - 936
  • [3] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Hentschel, M
    Brink, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (03) : 473 - 474
  • [4] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Michael Hentschel
    Ingo Brink
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 473 - 474
  • [5] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies (vol 30, pg 936, 2003)
    Erselcan, T
    Turgut, B
    Dogan, D
    Ozdemir, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (06) : 936 - 936
  • [6] Liver Standardized Uptake Value Corrected for Lean Body Mass at FDG PET/CT Effect of FDG Uptake Time
    Chirindel, Alin
    Alluri, Krishna C.
    Tahari, Abdel K.
    Chaudhry, Muhammad
    Wahl, Richard L.
    Lodge, Martin A.
    Subramaniam, Rathan M.
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (01) : E17 - E22
  • [7] Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging
    Tahari, Abdel K.
    Chien, David
    Azadi, Javad R.
    Wahl, Richard L.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) : 1481 - 1484
  • [8] Usefulness of standardized uptake value normalized by individual CT-based lean body mass in application of PET response criteria in solid tumors (PERCIST)
    Narita A.
    Shiomi S.
    Katayama Y.
    Yamanaga T.
    Daisaki H.
    Hamada K.
    Watanabe Y.
    Radiological Physics and Technology, 2016, 9 (2) : 170 - 177
  • [9] The Utility of CT-derived Lean Body Mass Correction of Weight-based Standardized Uptake Values.
    McEwan, Alexander
    Riauka, Terence
    Wieler, Marguerite
    Baracos, Vickie
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [10] Lean Body Mass Correction of Standardized Uptake Values in Simultaneous Whole-Body PET-MRI - proof of principle trial
    Sattler, B.
    Jochimsen, T. H.
    Schulz, J.
    Werner, P.
    Seese, A.
    Barthel, H.
    Sabri, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S239 - S239