Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies

被引:1
|
作者
Hentschel, M [1 ]
Brink, I [1 ]
机构
[1] Univ Freiburg, Div Nucl Med, PET Ctr, D-79106 Freiburg, Germany
关键词
D O I
10.1007/s00259-002-1084-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:473 / 474
页数:2
相关论文
共 35 条
  • [1] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Erselcan, T
    Turgut, B
    Dogan, D
    Ozdemir, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (12) : 1630 - 1638
  • [2] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Taner Erselcan
    Bulent Turgut
    Derya Dogan
    Semra Ozdemir
    European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 1630 - 1638
  • [3] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Taner Erselcan
    Bulent Turgut
    Derya Dogan
    Semra Ozdemir
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 936 - 936
  • [4] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies
    Michael Hentschel
    Ingo Brink
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 473 - 474
  • [5] Lean body mass-based standardized uptake value, derived from a predictive equation, might be misleading in PET studies (vol 30, pg 936, 2003)
    Erselcan, T
    Turgut, B
    Dogan, D
    Ozdemir, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (06) : 936 - 936
  • [6] Liver Standardized Uptake Value Corrected for Lean Body Mass at FDG PET/CT Effect of FDG Uptake Time
    Chirindel, Alin
    Alluri, Krishna C.
    Tahari, Abdel K.
    Chaudhry, Muhammad
    Wahl, Richard L.
    Lodge, Martin A.
    Subramaniam, Rathan M.
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (01) : E17 - E22
  • [7] Optimum Lean Body Formulation for Correction of Standardized Uptake Value in PET Imaging
    Tahari, Abdel K.
    Chien, David
    Azadi, Javad R.
    Wahl, Richard L.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) : 1481 - 1484
  • [8] Usefulness of standardized uptake value normalized by individual CT-based lean body mass in application of PET response criteria in solid tumors (PERCIST)
    Narita A.
    Shiomi S.
    Katayama Y.
    Yamanaga T.
    Daisaki H.
    Hamada K.
    Watanabe Y.
    Radiological Physics and Technology, 2016, 9 (2) : 170 - 177
  • [9] The Utility of CT-derived Lean Body Mass Correction of Weight-based Standardized Uptake Values.
    McEwan, Alexander
    Riauka, Terence
    Wieler, Marguerite
    Baracos, Vickie
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [10] Lean Body Mass Correction of Standardized Uptake Values in Simultaneous Whole-Body PET-MRI - proof of principle trial
    Sattler, B.
    Jochimsen, T. H.
    Schulz, J.
    Werner, P.
    Seese, A.
    Barthel, H.
    Sabri, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S239 - S239