Comparison of competitive-nested PCR and real-time PCR in detecting BCR-ABL fusion transcripts in chronic myeloid leukemia patients

被引:0
|
作者
JQ Guo
H Lin
H Kantarjian
M Talpaz
R Champlin
M Andreeff
A Glassman
RB Arlinghaus
机构
[1] University of Texas MD Anderson Cancer Center,Department of Molecular Pathology
[2] University of Texas MD Anderson Cancer Center,Department of Leukemia
[3] University of Texas MD Anderson Cancer Center,Department of Bioimmunotherapy
[4] University of Texas MD Anderson Cancer Center,Department of Bone Marrow Transplantation
[5] University of Texas MD Anderson Cancer Center,Department of Lab Medicine
来源
Leukemia | 2002年 / 16卷
关键词
real-time RT-PCR; quantitative competitive RT-PCR; BCR-ABL transcripts; chronic myeloid leukemia;
D O I
暂无
中图分类号
学科分类号
摘要
Real-time RT-PCR has great advantages for estimating transcript levels in a variety of situations. These include relative rapid assay times (hours), reliability and ease of performing replicate analyses. In contrast, competitive PCR is a very labor-intensive procedure requiring a few days to generate useful data. We compared the same samples from CML patients by both methods. Importantly, we used the Bcr-Abl junction plasmid DNA, which is used as a competitor in the manual competitive PCR assay, to generate a standard curve for the real-time assay. This permitted reporting the real-time data as the number of BCR-ABL transcripts per μg of total RNA, which is the same format used for the competitive PCR assay. In this study, a total of 435 peripheral blood and marrow samples from 285 CML patients were analyzed by RT-PCR; these patients were undergoing therapy by STI-571, interferon, and bone marrow transplantation treatment. Most samples also had assay values for the Philadelphia chromosome (Ph), FISH and Western blotting for the Bcr-Abl oncoprotein. Our findings indicated that the real-time assay was less sensitive than the manual competitive RT-PCR assay (t = 5.118; P < 0.001). Of interest, the transcript levels in cell line mixtures with various ratios of K562/KG-1 (BCR-ABL positive/negative) cells were also significantly higher with the competitive RT-PCR assays than real-time RT-PCR, except for levels of BCR-ABL below 200 transcripts per μg of RNA. In both patient and cell line experiments, dividing the BCR-ABL transcripts by the total ABL transcripts virtually eliminated the difference between real-time BCR-ABL transcript values and quantitative competitive BCR-ABL transcript values, indicating that both BCR-ABL and ABL transcripts were underestimated by the real-time assay. In addition, the increased sensitivity of the nested, competitive RT-PCR was readily apparent in patients with minimal residual disease, which by the real-time were negative in the majority of patients but were positive by nested, competitive RT-PCR in 44.6% (n = 29) of samples analyzed (n = 65). These findings indicate that real-time RT-PCR, when normalized for the total ABL transcripts, can be used to monitor CML patients during therapy, but we suggest that nested, competitive RT-PCR be used to determine BCR-ABL/ABL transcript ratios at low transcript values or especially when real-time analyses are negative.
引用
收藏
页码:2447 / 2453
页数:6
相关论文
共 50 条
  • [41] ANALYSIS OF BCR ABL TRANSCRIPTS IN CHRONIC MYELOID PATIENTS BY NESTED PCR USING AN IMMUNOASSAY-LIKE DETECTION FORMAT
    BARBU, V
    ALPHABAZIN, B
    PEPIN, D
    MORANDJOUBERT, L
    CHYPRE, C
    BEREZIAT, G
    MOLECULAR AND CELLULAR PROBES, 1994, 8 (03) : 251 - 256
  • [42] Detection of bcr-abl mRNA in single progenitor colonies from patients with chronic myeloid leukemia by PCR: Comparison with cytogenetics and PCR from uncultured cells
    Schulze, E
    Krahl, R
    Thalmeier, K
    Helbig, W
    EXPERIMENTAL HEMATOLOGY, 1995, 23 (14) : 1649 - 1654
  • [43] Our four-year experience with real-time PCR analysis used for quantification of BCR-ABL transcripts in haematological patients
    Beranek, M
    Voglova, J
    Zak, R
    Palicka, V
    CLINICA CHIMICA ACTA, 2005, 355 : S167 - S167
  • [44] The follow-up of therapy by RT-PCR detection of hybrid BCR-ABL transcripts in chronic myeloid leukemia.
    Guo, M
    Huang, SHM
    Dong, LJ
    Yao, B
    Pian, HY
    BLOOD, 1997, 90 (10) : 3990 - 3990
  • [45] International standardisation of quantitative real-time RT-PCR for BCR-ABL
    Cross, Nicholas C. P.
    Hughes, Timothy P.
    Hochhaus, Andreas
    Goldman, John M.
    LEUKEMIA RESEARCH, 2008, 32 (03) : 505 - 506
  • [46] Quantification of BCR/ABL levels by real-time RT-PCR correlates with cytogenetic response in patients with chronic myeloid leukemia (CML).
    Rossi, G
    Zanella, I
    Capucci, M
    Finazzi, D
    Pollonini, G
    Pavia, P
    Regazzoli, A
    Albertini, A
    Cariani, E
    BLOOD, 2000, 96 (11) : 257B - 257B
  • [47] Real-time quantitation of bcr-abl transcripts in haematological malignancies
    Saffroy, R
    Lemoine, A
    Brézillon, P
    Frénoy, N
    Delmas, B
    Goldschmidt, E
    Souleau, B
    Nedellec, G
    Debuire, B
    EUROPEAN JOURNAL OF HAEMATOLOGY, 2000, 65 (04) : 258 - 266
  • [48] MEASUREMENT OF BCR-ABL TRANSCRIPTS IN LONG-TERM ALLOGENEIC STEM CELL TRANSPLANTATION CIVIL PATIENTS BY REAL-TIME QUANTITATIVE PCR (RQ-PCR)
    Scholl, V.
    Bitencourt, R.
    Pires, V.
    Paditha, T. F.
    Hassan, R.
    Zalcberg, I. R.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 540 - 541
  • [49] Frequency of BCR-ABL fusion transcripts in Serbian patients with chronic myeloid leukemia (vol 16, pg 104, 2011)
    Todoric-Zivanovic, B.
    Strnad, M.
    Stamatovic, D.
    Tukic, L.
    Krtolica, K.
    Tatomirovic, Z.
    Djordjevic, V.
    Bogdanovic, A.
    Jankovic, G.
    Magic, Z.
    JOURNAL OF BUON, 2011, 16 (02):
  • [50] Quantitative and competitive RT-PCR and ''in cell RT-PCR'' for the detection of BCR-ABL transcript in chronic myeloid leukemia patients: Comparison of advantages and pitfalls of two promising methods.
    Martinelli, G
    Testoni, N
    Farabegoli, P
    Zaccaria, A
    Amabile, M
    Raspadori, D
    Pelliconi, S
    Terragna, C
    Vittone, A
    Tura, S
    BLOOD, 1996, 88 (10) : 2280 - 2280