Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis

被引:0
|
作者
Zhonghua Sun
Kwan-Hoong Ng
机构
[1] Curtin University,
[2] University of Malaya,undefined
关键词
Coronary artery disease; Image quality; Coronary CT angiography; Prospective ECG-gating; Radiation dose;
D O I
暂无
中图分类号
学科分类号
摘要
To perform a systematic review and meta-analysis of the diagnostic value of prospective ECG-gating coronary CT angiography in the diagnosis of coronary artery disease. A search of biomedical databases for English literature was performed to identify studies investigating the diagnostic value of 64- or more slice CT angiography with use of prospective ECG-gating in the diagnosis of coronary artery disease. Sensitivity, specificity, positive and negative predictive value estimates pooled across studies were tested using a fixed effects model. Fourteen studies met selection criteria for inclusion in the analysis. Pooled estimates and 95% confidence interval (CI) of sensitivity, specificity, positive and negative predictive value of prospective ECG-gating coronary CT angiography for diagnosis of significant coronary stenosis were 99% (95% CI: 98, 100%), 91% (95% CI: 88, 94%), 94% (95% CI: 91, 96%) and 99% (95% CI: 97, 100%), according to the patient-based assessment. The mean values of sensitivity, specificity, positive and negative predictive value of prospective ECG-gating coronary CT angiography were 95% (95% CI: 93, 96%), 95% (95% CI: 93, 95%), 88% (95% CI: 86, 90%), and 98% (95% CI: 97, 98%), according to vessel-based assessment; 92% (95% CI: 90, 93%), 97% (95% CI: 97, 98%), 84% (95% CI: 82, 86%), 99% (95% CI: 99, 99%), according to segment-based assessment, respectively. The mean effective dose was 3.3 mSv (95% CI: 2.3, 4.1 mSv) for the prospective ECG-gating coronary CT angiography. This analysis shows that for a predominantly male population with a high disease prevalence the use of coronary CT angiography with prospective ECG gating allows for a reduced radiation exposure without a sacrifice in diagnostic efficacy.
引用
收藏
页码:2109 / 2119
页数:10
相关论文
共 50 条
  • [1] Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis
    Sun, Zhonghua
    Ng, Kwan-Hoong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 2109 - 2119
  • [2] Diagnostic value of 320-slice coronary CT angiography in coronary artery disease: A systematic review and meta-analysis
    Lin, Chenghsun (jslin@ctust.edu.tw), 1600, Bentham Science Publishers (10):
  • [3] Diagnostic Value of 320-Slice Coronary CT Angiography in Coronary Artery Disease: A Systematic Review and Meta-Analysis
    Sun, Zhonghua
    Lin, Chenghsun
    CURRENT MEDICAL IMAGING REVIEWS, 2014, 10 (04) : 272 - 280
  • [4] Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease
    Yang, Linfeng
    Zhou, Tao
    Zhang, Ruijie
    Xu, Lin
    Peng, Zhaohui
    Ding, Juan
    Wang, Sen
    Li, Min
    Sun, Gang
    EUROPEAN RADIOLOGY, 2014, 24 (10) : 2345 - 2352
  • [5] Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease
    Linfeng Yang
    Tao Zhou
    Ruijie Zhang
    Lin Xu
    Zhaohui Peng
    Juan Ding
    Sen Wang
    Min Li
    Gang Sun
    European Radiology, 2014, 24 : 2345 - 2352
  • [6] COMPARISON OF DIAGNOSTIC ACCURACY OF CORONARY CT ANGIOGRAPHY BETWEEN RETROSPECTIVE ECG-GATING WITH DOSE MODULATION AND VIRTUAL PROSPECTIVE ECG GATING WITH AND WITHOUT PADDING
    Takaoka, Hiroyuki
    Funabashi, Nobusada
    Uehara, Masae
    Ozawa, Koya
    Kobayashi, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1338 - E1338
  • [7] The diagnostic value of non-contrast magnetic resonance coronary angiography in the assessment of coronary artery disease: A systematic review and meta-analysis
    Zahergivar, Aryan
    Kocher, Madison
    Waltz, Jeffrey
    Kabakus, Ismail
    Chamberlin, Jordan
    Akkaya, Selcuk
    Agha, Ali M.
    Schoepf, U. Joseph
    Burt, Jeremy R.
    HELIYON, 2021, 7 (03)
  • [8] Prospective and retrospective ECG-gating for CT coronary angiography perform similarly accurate at low heart rates
    Stolzmann, Paul
    Goetti, Robert
    Baumueller, Stephan
    Plass, Andre
    Falk, Volkmar
    Scheffel, Hans
    Feuchtner, Gudrun
    Marincek, Borut
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 85 - 91
  • [9] Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review
    Sun, Zhonghua
    Lin, ChengHsun
    Davidson, Robert
    Dong, Chiauhuei
    Liao, Yunchan
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) : 78 - 84
  • [10] Magnetocardiography for the Diagnosis of Coronary Artery Disease - A Systematic Review and Meta-Analysis
    Agarwal, Rajender
    Saini, Abhimanyu
    Alyousef, Tareq
    Umscheid, Craig A.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2012, 17 (04) : 291 - 298