Validation of MCNP for large-sample thermal-beam prompt-gamma neutron activation analysis

被引:0
|
作者
I. H. Degenaar
M. Blaauw
P. Bode
J. J. M. de Goeij
机构
[1] Delft University of Technology Mekelweg 15,Interfaculty Reactor Institute
关键词
Instrumental Neutron Activation Analysis; Copper Wire; Neutron Beam; Neutron Monitor; Comparison Process;
D O I
暂无
中图分类号
学科分类号
摘要
A benchmark study was carried out to verify whether MCNP is useful in the design stage of a PGNAA facility for large samples up to 1 m length and 0.15 m diameter, using a 2.54 cm diameter thermal neutron beam. For this facility neutron self-shielding and gamma-attenuation correction methods have to be developed. The relative spatial neutron-density distributions within three samples with different macroscopic scattering and absorption cross sections were studied in a comparison between an MCNP simulation and an irradiation experiment using copper wires as neutron monitors. The neutron density in the sample was within statistical agreement between experiment and simulation. Typically the relative spatial neutron-density distributions agreed to within 1%. Therefore, MCNP can be used in design studies for the development of a large sample PGNAA facility as specified.
引用
收藏
页码:311 / 315
页数:4
相关论文
共 50 条
  • [31] ABUNDANCE OF BORON IN INTERNATIONAL GEOCHEMICAL STANDARDS BY PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS
    HIGGINS, MD
    GEOSTANDARDS NEWSLETTER, 1984, 8 (01): : 31 - 34
  • [32] Design of a prompt-gamma neutron activation analysis system on China Advanced Research Reactor
    Sun Hongchao
    Ni Bangfa
    Xiao Caijin
    Zhang Guiying
    Liu Cunxiong
    Huang Jinfeng
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (05) : 287 - 292
  • [33] Application of cold neutron prompt-gamma activation analysis in environmental studies of aquatic plants
    Zhao, L.
    Robinson, L.
    Paul, R. L.
    Greenberg, R. R.
    Miao, S. L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (03) : 777 - 782
  • [34] DETERMINING THE ABUNDANCE OF GADOLINIUM IN GEOLOGICAL SAMPLES BY PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS
    BERGERON, M
    HEAMAN, LM
    CHEMICAL GEOLOGY, 1986, 54 (3-4) : 333 - 337
  • [35] In vivo total body chlorine measurements using prompt-gamma neutron activation analysis
    Shypailo, RJ
    Ellis, KJ
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 236 (1-2) : 19 - 23
  • [36] In vivo assessment of total body protein in rats by prompt-gamma neutron activation analysis
    Stamatelatos, IE
    Boozer, CN
    Ma, RM
    Yasumura, S
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 379 - 382
  • [37] Digital signal processing in prompt-gamma activation analysis
    Szentmiklósi, L
    Belgya, T
    Révay, Z
    Molnár, GL
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (01) : 229 - 234
  • [38] Reference material certification by prompt-gamma activation analysis
    Lindstrom, RM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (3-4): : 322 - 324
  • [39] DEVELOPMENT AND APPLICATIONS OF AN ON-LINE THERMAL NEUTRON PROMPT-GAMMA ELEMENT ANALYSIS SYSTEM
    刘雨人
    卢允信
    谢亚丽
    王永海
    杜幼玲
    谈进
    孟伯年
    R.S.Seymour
    Nuclear Science and Techniques, 1991, (02) : 71 - 78
  • [40] DEVELOPMENT AND APPLICATIONS OF AN ONLINE THERMAL-NEUTRON PROMPT-GAMMA ELEMENT ANALYSIS SYSTEM
    LIU, YR
    LU, YX
    XIE, Y
    WANG, YH
    DU, YL
    TAN, J
    MENG, BN
    SEYMOUR, RS
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1991, 151 (01): : 83 - 93