Validation of MCNP for large-sample thermal-beam prompt-gamma neutron activation analysis

被引:0
|
作者
I. H. Degenaar
M. Blaauw
P. Bode
J. J. M. de Goeij
机构
[1] Delft University of Technology Mekelweg 15,Interfaculty Reactor Institute
关键词
Instrumental Neutron Activation Analysis; Copper Wire; Neutron Beam; Neutron Monitor; Comparison Process;
D O I
暂无
中图分类号
学科分类号
摘要
A benchmark study was carried out to verify whether MCNP is useful in the design stage of a PGNAA facility for large samples up to 1 m length and 0.15 m diameter, using a 2.54 cm diameter thermal neutron beam. For this facility neutron self-shielding and gamma-attenuation correction methods have to be developed. The relative spatial neutron-density distributions within three samples with different macroscopic scattering and absorption cross sections were studied in a comparison between an MCNP simulation and an irradiation experiment using copper wires as neutron monitors. The neutron density in the sample was within statistical agreement between experiment and simulation. Typically the relative spatial neutron-density distributions agreed to within 1%. Therefore, MCNP can be used in design studies for the development of a large sample PGNAA facility as specified.
引用
收藏
页码:311 / 315
页数:4
相关论文
共 50 条
  • [1] Validation of MCNP for large-sample thermal-beam prompt-gamma neutron activation analysis
    Degenaar, IH
    Blaauw, M
    Bode, P
    de Goeij, JJM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 260 (02) : 311 - 315
  • [2] Validation experiment for large-sample prompt-gamma neutron activation analysis
    M. Blaauw
    I. H. Degenaar
    C. Yonezawa
    H. Matsue
    J. J. M. de Goeij
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 271 : 745 - 750
  • [3] Validation experiment for large-sample prompt-gamma neutron activation analysis
    Blaauw, M.
    Degenaar, I. H.
    Yonezawa, C.
    Matsue, H.
    de Goeij, J. J. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (03) : 745 - 750
  • [4] Correction for neutron self-shielding in large-sample prompt-gamma neutron activation analysis
    I. H. Degenaar
    M. Blaauw
    J. J. M. de Goeij
    Journal of Radioanalytical and Nuclear Chemistry, 2003, 257 : 467 - 470
  • [5] Correction for neutron self-shielding in large-sample prompt-gamma neutron activation analysis - Determination of macroscopic neutron cross sections
    Degenaar, IH
    Blaauw, M
    de Goeij, JJM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 257 (03) : 467 - 470
  • [6] Development of a non-invasive method for the determination of the macroscopic neutron cross sections of a sample matrix in large-sample prompt-gamma neutron activation analysis
    Blaauw, M.
    Degenaar, I. H.
    de Goeij, J. J. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (03) : 765 - 770
  • [7] Development of a non-invasive method for the determination of the macroscopic neutron cross sections of a sample matrix in large-sample prompt-gamma neutron activation analysis
    M. Blaauw
    I. H. Degenaar
    J. J. M. de Goeij
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 271 : 765 - 770
  • [8] Estimation of background interference in prompt-gamma neutron activation using MCNP
    R. J. Shypailo
    K. J. Ellis
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 249 (2) : 407 - 412
  • [9] Estimation of background interference in prompt-gamma neutron activation using MCNP
    Shypailo, RJ
    Ellis, KJ
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (02) : 407 - 412
  • [10] Capillary neutron optics for prompt-gamma activation analysis
    ChenMayer, HH
    Sharov, VA
    Mildner, DFR
    Downing, RG
    Paul, RL
    Lindstrom, RM
    Zeissler, CJ
    Xiao, QF
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (01) : 141 - 145