Automated Sequential Injection Method for Determination of Caffeine in Coffee Drinks

被引:0
|
作者
Lýdia Mihalčíková
Warunya Boonjob
Hana Sklenářová
机构
[1] Charles University,Department of Analytical Chemistry, Faculty of Pharmacy
来源
Food Analytical Methods | 2018年 / 11卷
关键词
Automation; Coffee drinks; Monolithic column; Sequential injection analysis; Purine alkaloids;
D O I
暂无
中图分类号
学科分类号
摘要
An automated sequential injection analysis spectrophotometric assay for the determination of purine alkaloids in coffee drinks was developed. The sample was treated with a carrez reagent for matrix suppression followed by filtration; subsequently, alkaloids were separated from organic acids using a short C18 monolithic column (10 × 4.6 mm). The flow rate of the separation step was 10 μL s−1 with 10% v/v of methanol as the mobile phase. The sum of alkaloids evaluated as caffeine was detected at 274 nm. The influence of the main parameters affecting the quantification of purine alkaloids was optimized. One sample analysis lasted 15 min when aspirated in triplicate. The linear range was 1–15 mg L−1, and the determination coefficient (r2) was 0.9969. The limit of detection and limit of quantitation were 0.128 and 0.425 mg L−1, respectively. The repeatability evaluated as the relative standard deviation (RSD) was 3.58% (n = 12, 10 mg L−1). Under optimal conditions, the method was successfully applied to determine purine alkaloids in different real samples including soluble coffee, coffee from an espresso machine, and brewed coffee drinks.
引用
收藏
页码:111 / 118
页数:7
相关论文
共 50 条
  • [21] A NEW THIN-LAYER-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF CAFFEINE IN COFFEE
    WASHUTTL, J
    BANCHER, E
    RIEDERER, P
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1970, 143 (04): : 253 - &
  • [22] Automated Determination of Captopril by Flow and Sequential Injection Analysis: A Review
    Tzanavaras, Paraskevas D.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 560 - 576
  • [23] DETERMINATION OF CAFFEINE IN SOFT DRINKS AND CAFFEINE-CONTAINING FOOD PREPARATIONS
    FRISCHKORN, CGB
    FRISCHKORN, HE
    ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1975, 158 (05): : 295 - 299
  • [24] The determination of caffeine in coffee: Sense or nonsense?
    Beckers, JL
    JOURNAL OF CHEMICAL EDUCATION, 2004, 81 (01) : 90 - 93
  • [25] HPLC determination of caffeine in coffee beverage
    Fajara, B. E. P.
    Susanti, H.
    INTERNATIONAL PHARMACY CONFERENCE UAD 2017 ON PRODUCT AUTHENTICATION: KEY FACTOR IN QUALITY CONTROL OF PHARMACEUTICAL PRODUCTS, 2017, 259
  • [26] Sequential injection chromatographic determination of paracetamol, caffeine, and acetylsalicylic acid in pharmaceutical tablets
    Satínsky, D
    Neto, I
    Solich, P
    Sklenárová, H
    Conceiçao, M
    Montenegro, BSM
    Araújo, AN
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (7-8): : 529 - 536
  • [27] A gas chromatographic method for determination of nicotinamide, paraben esters and caffeine in commercial health drinks, tonic drinks and cold formulas
    Lin, HJ
    Wang, ML
    Chen, CW
    Hwang, BS
    Lee, MH
    Choong, YM
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2000, 8 (03) : 180 - 186
  • [28] Sequential injection Fourier transform infrared spectroscopy for the simultaneous determination of organic acids and sugars in soft drinks employing automated solid phase extraction
    LeThanh, H
    Lendl, B
    ANALYTICA CHIMICA ACTA, 2000, 422 (01) : 63 - 69
  • [29] A ROUTINE METHOD FOR DETERMINING CAFFEINE IN COFFEE AND COFFEE MIXTURES
    KUMTATT, L
    ANALYST, 1961, 86 (102) : 825 - +
  • [30] Spectrometric determination of trimethoprim and sulfamethoxazole in tablets by automated sequential injection technique
    Nesmerak, Karel
    Kroiherova, Anna
    Baptistova, Adela
    Hranicek, Jakub
    MONATSHEFTE FUR CHEMIE, 2020, 151 (08): : 1311 - 1316