Total hip arthroplasty using a Kerboull-type plate for rapidly destructive coxarthrosis: comparison with uncemented acetabular component

被引:6
|
作者
Baba T. [1 ]
Homma Y. [1 ]
Ochi H. [1 ]
Ozaki Y. [1 ]
Matsumoto M. [1 ]
Shitoto K. [2 ]
Kaneko K. [1 ]
机构
[1] Department of Orthopedic Surgery, Juntendo University School of Medicine, 2-1-1 Hongo, Bunkyo-ku, Tokyo
[2] Department of Orthopedic Surgery, Juntendo Urayasu Hospital, Chiba
关键词
Kerboull-type plate; Rapidly destructive coxarthrosis; Total hip arthroplasty; Uncemented acetabular component;
D O I
10.1007/s00590-015-1738-7
中图分类号
学科分类号
摘要
Introduction: Clinical outcomes of total hip arthroplasty (THA) to treat rapidly destructive coxarthrosis (RDC) have been reported, but to our knowledge, there have been no studies comparing implants. The aim of this study was to examine the effectiveness of acetabular reconstruction for RDC by comparing the clinical results of THA using a Kerboull-type plate with an uncemented cup. Patients and methods: Among 921 primary THAs performed between 2006 and 2014, 27 were performed for the treatment for RDC using a Kerboull-type plate or a conventional uncemented cup. A Kerboull-type plate for acetabular reinforcement device was used in 13 hips and an uncemented cup in 14 hips. The mean follow-up period was 61.2 months. Results: The duration of surgery was 156.8 ± 36.4 min in the Kerboull-type plate group and 103.3 ± 14.4 min in the uncemented cup group, being significantly longer in the former (P = 0.0002). In the Kerboull-type plate group and the uncemented cup group, the 5-year survival rates were 100 and 83.9 %, respectively. Recurrent dislocation was observed in two cases in which the posterior approach had been used. Conclusions: In our study, the loosening of the acetabular components was noted in 14.3 % of uncemented cup-applied cases, but no loosening was noted in any Kerboull-type plate-applied case. Therefore, for RDC, in which objective evaluation of fragile bone quality is difficult, the use of the Kerboull-type plate, which disperses weight-bearing of the acetabular, may be an effective means to achieve early functional recovery as well as a long-term favorable outcome. © 2016, Springer-Verlag France.
引用
收藏
页码:189 / 194
页数:5
相关论文
共 50 条
  • [41] Major acetabular defects: outcomes of first revision total hip arthroplasty using Kerboull cross-plate with allograft and cemented dual mobility cup at a maximum follow-up of fourteen years
    Chahine Assi
    Jad Mansour
    Karl Boulos
    Jacques Caton
    Camille Samaha
    Elie El-Kayyem
    Kaissar Yammine
    [J]. International Orthopaedics, 2022, 46 : 2539 - 2546
  • [42] Long-term results of the uncemented acetabular component in a primary total hip arthroplasty performed for protrusio acetabuli: a fifteen year median follow-up
    Baghdadi, Yaser M. K.
    Larson, A. Noelle
    Sierra, Rafael J.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (05) : 839 - 845
  • [43] Long-term results of the uncemented acetabular component in a primary total hip arthroplasty performed for protrusio acetabuli: a fifteen year median follow-up
    Yaser M. K. Baghdadi
    A. Noelle Larson
    Rafael J. Sierra
    [J]. International Orthopaedics, 2015, 39 : 839 - 845
  • [44] Uncemented third-generation ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner
    Tsukada, Sachiyuki
    Wakui, Motohiro
    Matsueda, Munenori
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 861 - 868
  • [45] Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up
    Schramm, M
    Hohmann, D
    Pitto, RP
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (7-8) : 407 - 412
  • [46] Uncemented third-generation ceramic-on-ceramic total hip arthroplasty using metal acetabular shell with direct taper locking liner
    Sachiyuki Tsukada
    Motohiro Wakui
    Munenori Matsueda
    [J]. Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 861 - 868
  • [47] Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up
    M. Schramm
    F. Keck
    D. Hohmann
    R. P. Pitto
    [J]. Archives of Orthopaedic and Trauma Surgery, 2000, 120 : 407 - 412
  • [48] The removal of acetabular bone in hip resurfacing and cementless total hip replacement A COMPARISON USING THE RATIO OF THE SIZE OF THE ACETABULAR COMPONENT TO THE DIAMETER OF THE NATIVE FEMORAL HEAD
    Cross, M. B.
    Dolan, M. M.
    Sidhu, G. S.
    Nguyen, J.
    Mayman, D. J.
    Su, E. P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (10): : 1339 - 1343
  • [49] Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty?
    Jacobs, C. A.
    Kusema, E. T.
    Keeney, B. J.
    Moschetti, W. E.
    [J]. BONE & JOINT JOURNAL, 2019, 101B (05): : 529 - 535
  • [50] Immediate weight bearing after uncemented total hip arthroplasty with an anteverted stem -: A prospective randomized comparison using radiostereometry
    Thien, Truike M.
    Ahnfelt, Lennart
    Eriksson, Mikael
    Stromberg, Christer
    Karrholm, Johan
    [J]. ACTA ORTHOPAEDICA, 2007, 78 (06) : 730 - 738