Technical aspects of multifocal ERG recording

被引:36
|
作者
David Keating
Stuart Parks
Aled Evans
机构
[1] Gartnavel General Hospital,ElectroDiagnostic Imaging Unit, Tennent Institute of Ophthalmology
[2] Southern General Hospital,Department of Clinical Physics & Bio
关键词
multifocal analysis; multifocal ERG; stimulus delivery;
D O I
10.1023/A:1002723501303
中图分类号
学科分类号
摘要
There are a wide range of variables which can influence the quality of the multifocal response. It is possible to place these variables into one of four categories. First, the method of stimulus delivery will determine the field of view, interference levels and the duration of on-state stimulation. Second, data acquisition variables such as electrode type and placement, amplifier specifications and filter bandwidth settings will have a direct impact on waveform shape and on the topographic distribution of signal amplitudes. Third, patient variables such as fixation, pupil dilation and refractive error will also contribute to the multifocal response. Fourth, there are many measurements that can be taken from multifocal recordings. In addition to standard amplitude and implicit time measures (the implicit time measure in the multifocal response is becoming increasingly important particularly in early stages of disease processes), the scalar product measure provides information on waveform shape. The conventional impulse and higher order responses will be different for different modes of stimulation such as Cathode Ray Tube (CRT) and Liquid Crystal Display (LCD) systems and latency shifts will be introduced if not corrected in software. Procedures which could lead to misleading interpretation include artefact rejection, averaging with neighbours and summing of responses. These procedures should be handled with caution.
引用
收藏
页码:77 / 98
页数:21
相关论文
共 50 条
  • [21] The reproducibility of multifocal ERG recordings
    Meigen, T
    Friedrich, A
    OPHTHALMOLOGE, 2002, 99 (09): : 713 - 718
  • [22] Multifocal ERG in macular disease
    Klemp, K.
    ACTA OPHTHALMOLOGICA, 2008, 86 : 34 - 34
  • [23] The multifocal ERG in hydroxychloroquine patients
    Markoff, JI
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U275 - U275
  • [24] Multifocal ERG Responses in Infants
    Hansen, Ronald M.
    Moskowitz, Anne
    Fulton, Anne B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (01) : 470 - 475
  • [25] The influence of luminance on the multifocal ERG
    Thilo Schimitzek
    Michael Bach
    Documenta Ophthalmologica, 2006, 113 : 187 - 192
  • [26] Multifocal ERG in retinal degeneration
    Kuniyoshi, K
    Arai, M
    Koo, H
    Vitral, NP
    Hirose, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4118 - 4118
  • [27] Multifocal ERG changes in glaucoma
    Chan, HL
    Brown, B
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1999, 19 (04) : 306 - 316
  • [28] Technical aspects of mechnomyography recording with piezoelectric contact sensor
    Watakabe, M
    Itoh, Y
    Mita, K
    Akataki, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) : 557 - 561
  • [29] Multichannel sound recording of music: Practical and technical aspects
    Hamasaki, K
    Hiyama, K
    PROCEEDINGS OF THE AES 19TH INTERNATIONAL CONFERENCE SURROUND SOUND: TECHNIQUES, TECHNOLOGY AND PERCEPTION, 2001, : 447 - 447
  • [30] Technical aspects of mechnomyography recording with piezoelectric contact sensor
    M. Watakabe
    Y. Itoh
    K. Mita
    K. Akataki
    Medical and Biological Engineering and Computing, 1998, 36 : 557 - 561