A comparative study of digital PCR and real-time qPCR for the detection and quantification of HPV mRNA in sentinel lymph nodes of cervical cancer patients

被引:15
|
作者
Carow K. [1 ]
Read C. [2 ]
Häfner N. [1 ]
Runnebaum I.B. [1 ]
Corner A. [2 ]
Dürst M. [1 ]
机构
[1] Klinik und Poliklinik für Frauenheilkunde und Fortpflanzungsmedizin, Universitätsklinikum Jena, Am Klinikum 1, Jena
[2] RainDance Technologies, 749 Middlesex Turnpike, Billerica, 01821, MA
关键词
Cervical cancer; Digital PCR; HPV mRNA; Molecular marker; Quantitative PCR; Recurrence; Sentinel lymph node;
D O I
10.1186/s13104-017-2846-8
中图分类号
学科分类号
摘要
Background: Qualitative analyses showed that the presence of HPV mRNA in sentinel lymph nodes of cervical cancer patients with pN0 status is associated with significantly decreased recurrence free survival. To further address the clinical potential of the strategy and to define prognostic threshold levels it is necessary to use a quantitative assay. Here, we compare two methods of quantification: digital PCR and standard quantitative PCR. Methods: Serial dilutions of 5 ng-5 pg RNA (≈ 500-0.5 cells) of the cervical cancer cell line SiHa were prepared in 5 μg RNA of the HPV-negative human keratinocyte cell line HaCaT. Clinical samples consisted of 10 sentinel lymph nodes with varying HPV transcript levels. Reverse transcription of total RNA (5 μg RNA each) was performed in 100 μl and cDNA aliquots were analyzed by qPCR and dPCR. Digital PCR was run in the RainDrop® Digital PCR system (RainDance Technologies) using a probe-based detection of HPV E6/E7 cDNA PCR products with 11 μl template. qPCR was done using a Rotor Gene Q 5plex HRM (Qiagen) amplifying HPV E6/E7 cDNA in a SYBR Green format with 1 μl template. Results: For the analysis of both, clinical samples and serial dilution samples, dPCR and qPCR showed comparable sensitivity. With regard to reproducibility, both methods differed considerably, especially for low template samples. Here, we found with qPCR a mean variation coefficient of 126% whereas dPCR enabled a significantly lower mean variation coefficient of 40% (p = 0.01). Generally, we saw with dPCR a substantial reduction of subsampling errors, which most likely reflects the large cDNA amounts available for analysis. Conclusions: Compared to real-time PCR, dPCR shows higher reliability. Thus, our HPV mRNA dPCR assay holds promise for the clinical evaluation of occult tumor cells in histologically tumor-free lymph nodes in future studies. © 2017 The Author(s).
引用
收藏
相关论文
共 50 条
  • [21] A Real-Time PCR Assay for HPV52 Detection and Viral Load Quantification
    Onyekwuluje, Juanita M.
    Steinau, Martin
    Swan, David C.
    Unger, Elizabeth R.
    CLINICAL LABORATORY, 2012, 58 (1-2) : 61 - 66
  • [22] Detection of metastasis in axillary sentinel lymph nodes from breast cancer patients with real-time reverse transcription polymerase chain reaction
    Fang, WJ
    Sahain, A
    Luthra, R
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1999, 112 (04) : 539 - 540
  • [23] PHASE I STUDY FOR THE SENSITIVITY OF APTIMA TEST TO DETECT HPV MRNA IN LYMPH NODES OF PATIENTS WITH INVASIVE CERVICAL CANCER
    Lee, X.
    Dogan, N. U.
    Garagozova, N.
    Pfiffer, T.
    Beier, A.
    Nagel, E.
    Schneider, A.
    Koehler, C.
    Favero, G.
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (09) : 778 - 779
  • [24] A pilot study of quantitative real-time polymerase chain reaction metastases detection on sentinel lymph nodes of oral cancer and literature review
    Couto, Eduardo Vieira
    Lau, Fabio
    Gazmenga, Fabio Portella
    Texeira, Daniel
    Bertuzzo, Carmen Silvia
    Chone, Carlos Takahiro
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2024, 70
  • [25] A pilot study of quantitative real-time polymerase chain reaction metastases detection on sentinel lymph nodes of oral cancer and literature review
    Couto, Eduardo Vieira
    Lau, Fabio
    Gazmenga, Fabio Portella
    Texeira, Daniel
    Bertuzzo, Carmen Silvia
    Chone, Carlos Takahiro
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2024, 70
  • [26] Real-time PCR (TaqMan PCR) quantification of carcinoembryonic antigen (CEA) mRNA in the peripheral blood of colorectal cancer patients
    Miura, M
    Ichikawa, Y
    Tanaka, K
    Kamiyama, M
    Hamaguchi, Y
    Ishikawa, T
    Yamaguchi, S
    Togo, S
    Ike, H
    Ooki, S
    Shimada, H
    ANTICANCER RESEARCH, 2003, 23 (2B) : 1271 - 1276
  • [27] Study of HPV infection in tissues of tumor and lymph nodes of patients with cervical cancer.
    Nerodo, Galina Andreevna
    Kit, Oleg Ivanovich
    Zykova, Tatyana A.
    Ivanova, Victoria A.
    Nikitina, Vera
    Verenikina, Ekaterina V.
    Chernikova, Natalia V.
    Poryvaev, Yuriy A.
    Selezneva, Olga
    Bogomolova, Olga A.
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (15)
  • [28] Quantitative detection of micrometastases in pelvic lymph nodes in patients with clinically localized prostate cancer by real-time reverse transcriptase-PCR
    Miyake, Hideaki
    Hara, Isao
    Kurahashi, Toshifumi
    Inoue, Taka-aki
    Eto, Hiroshi
    Fujisawa, Masato
    CLINICAL CANCER RESEARCH, 2007, 13 (04) : 1192 - 1197
  • [29] Biomarker selection for detection of occult tumour cells in lymph nodes of colorectal cancer patients using real-time quantitative RT–PCR
    L Ohlsson
    M-L Hammarström
    A Israelsson
    L Näslund
    Å Öberg
    G Lindmark
    S Hammarström
    British Journal of Cancer, 2006, 95 : 218 - 225
  • [30] Laparoscopic detection of sentinel lymph nodes followed by lymph node dissection in patients with early stage cervical cancer
    Buist, MR
    Pijpers, RJ
    van Lingen, A
    van Diest, PJ
    Dijkstra, J
    Kenemans, P
    Verheijen, RHM
    GYNECOLOGIC ONCOLOGY, 2003, 90 (02) : 290 - 296