An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images

被引:0
|
作者
Anne-Doerte Achtert
Michael A. King
Seth T. Dahlberg
P. Hendrik Pretorius
Karen J. LaCroix
Benjamin M. W. Tsui
机构
[1] University of Massachusetts Medical Center,Department of Nuclear Medicine
[2] Humboldt University,undefined
[3] University of North Carolina at Chapel Hill,undefined
来源
关键词
Nuclear Cardiology; Perfusion Defect; Right Coronary Artery; Hepatic Uptake; Cardiac Volume;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:144 / 152
页数:8
相关论文
共 50 条
  • [21] Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes
    Slart, Riemer H. J. A.
    Tio, Rene A.
    Zeebregts, Clark J.
    Willemsen, Antoon T. M.
    Dierckx, Rudi A. J. O.
    De Sutter, Johan
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (03) : 171 - 176
  • [22] Assessment of left ventricular ejection fraction measured by quantitative gated SPECT
    Abe, K
    Hirakawa, K
    Yonenaga, T
    Kobayashi, S
    Nishimura, M
    Ayabe, Z
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (02): : 223 - 230
  • [23] The utility of gated SPECT imaging in quantitative analysis of regional ejection fraction
    Afshar, M
    Tilkemeier, P
    CHEST, 2005, 127 (03) : 701 - 702
  • [24] DETECTABILITY OF PERFUSION DEFECT IN GATED DYNAMIC CARDIAC SPECT IMAGES
    Niu, Xiaofeng
    Yang, Yongyi
    Wernick, Miles N.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 923 - 926
  • [25] Quantitative gated cardiac SPECT: Measuring diastolic function.
    Damrongpipatkij, Y
    Mohammed, F
    Brown, EJ
    Alhaddad, IA
    Heller, EN
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 154P - 154P
  • [26] Comparison of Gated Blood Pool SPECT with cardiac ultrasound for quantification of left ventricular volumes and ejection fraction.
    Bugriy, M.
    Rogunova, N.
    Saidova, M.
    Sergienko, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S311 - S311
  • [27] Comparison of automated gated myocardial SPECT with cardiac magnetic resonance for evaluation of left ventricular volumes and ejection fraction
    Persson, E
    Carlsson, M
    Palmer, J
    Pahlm, O
    Arheden, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S312 - S312
  • [28] Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes
    Demir, Hakan
    Tan, Yusuf Z.
    Kozdag, Guliz
    Isgoren, Serkan
    Anik, Yonca
    Ural, Dilek
    Demirci, Ali
    Berk, Fatma
    ANNALS OF SAUDI MEDICINE, 2008, 27 (06) : 415 - 420
  • [29] Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation of the exini heart software package
    Winz, Oliver H.
    Meyer, Philipp T.
    Knollmann, Daniela
    Lipke, Claudia S. A.
    Kuhl, Harald P.
    Oelve, Carola
    Schaefer, Wolfgang M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (02) : 89 - 94
  • [30] Automatic determination of LV ejection fraction and volumes by gated blood pool SPECT.
    Vanhove, C
    Everaert, H
    Bossuyt, A
    Franken, PR
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 187P - 187P