Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay

被引:0
|
作者
Sameh Kaziz
Ibrahim Ben Mariem
Fraj Echouchene
Mohamed Hichem Gazzah
Hafedh Belmabrouk
机构
[1] University of Monastir,Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir
[2] University of Tunis,Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard
[3] University of Monastir,Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir
[4] Majmaah University,Department of Physics, College of Science at Al Zulfi
来源
Indian Journal of Physics | 2022年 / 96卷
关键词
Biosensor; SARS-CoV-2 S protein; ACET flow; Design parameters; Detection time;
D O I
暂无
中图分类号
学科分类号
摘要
To combat the coronavirus disease 2019 (COVID-19), great efforts have been made by scientists around the world to improve the performance of detection devices so that they can efficiently and quickly detect the virus responsible for this disease. In this context we performed 2D finite element simulation on the kinetics of SARS-CoV-2 S protein binding reaction of a biosensor using the alternating current electrothermal (ACET) effect. The ACET flow can produce vortex patterns, thereby improving the transportation of the target analyte to the binding surface and thus enhancing the performance of the biosensor. Optimization of some design parameters concerning the microchannel height and the reaction surface, such as its length as well as its position on the top wall of the microchannel, in order to improve the biosensor efficiency, was studied. The results revealed that the detection time can be improved by 55% with an applied voltage of 10 Vrms and an operating frequency of 150 kHz and that the decrease in the height of the microchannel and in the length of the binding surface can lead to an increase in the rate of the binding reaction and therefore decrease the biosensor response time. Also, moving the sensitive surface from an optimal position, located in front of the electrodes, decreases the performance of the device.
引用
收藏
页码:4091 / 4101
页数:10
相关论文
共 50 条
  • [1] Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay
    Kaziz, S.
    Ben Mariem, I
    Echouchene, F.
    Gazzah, M. H.
    Belmabrouk, H.
    [J]. INDIAN JOURNAL OF PHYSICS, 2022, 96 (14) : 4091 - 4101
  • [2] The Study of Sensing Elements Parameters Optimization for Developed Biosensor of SARS-CoV-2 Detection
    Halim, Fatin Syakirah
    Parmin, N. A.
    Hashim, Uda
    Gopinanth, Subash C. B.
    Dahalan, Farrah Aini
    Zakaria, Iffah Izzati
    Ang, Wei Chern
    Jaapar, Nurfareezah Nadhirah
    [J]. INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2023, 16 (02): : 441 - 450
  • [3] Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2
    Krsihna, B. Vamsi
    Ahmadsaidulu, Shaik
    Teja, Surapaneni Sai Tarun
    Jayanthi, D.
    Navaneetha, Alluri
    Reddy, P. Rahul
    Prakash, M. Durga
    [J]. SILICON, 2022, 14 (11) : 5913 - 5921
  • [4] Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2
    B. Vamsi Krsihna
    Shaik Ahmadsaidulu
    Surapaneni Sai Tarun Teja
    D. Jayanthi
    Alluri Navaneetha
    P. Rahul Reddy
    M. Durga Prakash
    [J]. Silicon, 2022, 14 : 5913 - 5921
  • [5] Rapid field determination of SARS-CoV-2 by a colorimetric and fluorescent dual-functional lateral flow immunoassay biosensor
    Han, Han
    Wang, Chongwen
    Yang, Xingsheng
    Zheng, Shuai
    Cheng, Xiaodan
    Liu, Zhenzhen
    Zhao, Baohua
    Xiao, Rui
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2022, 351
  • [6] Rapid SARS-CoV-2 S-protein Detection using Nanostructured Electrochemical Biosensor
    Trafela, Spela
    Korent, Anja
    Soderznik, Kristina Zagar
    Zuzek, Kristina
    Sturm, Saso
    [J]. 2022 IEEE SENSORS, 2022,
  • [7] A Dielectric Modulated Biosensor for SARS-CoV-2
    Yadav, Shivendra
    Gedam, Anju
    Tirkey, Sukeshni
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (13) : 14483 - 14490
  • [8] In-silico design of a potential inhibitor of SARS-CoV-2 S protein
    Jaiswal, Grijesh
    Kumar, Veerendra
    [J]. PLOS ONE, 2020, 15 (10):
  • [9] Rapid detection of SARS-CoV-2: The gradual boom of lateral flow immunoassay
    He, Jing
    Zhu, Shuying
    Zhou, Jiawei
    Jiang, Wenjie
    Yin, Liliang
    Su, Lan
    Zhang, Xinling
    Chen, Qi
    Li, Xiaoping
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 10
  • [10] Rapid lateral flow immunoassay for the fluorescence detection of SARS-CoV-2 RNA
    Daming Wang
    Shaogui He
    Xiaohui Wang
    Youqin Yan
    Jianzhong Liu
    Shimin Wu
    Shiguo Liu
    Yang Lei
    Min Chen
    Li Li
    Jieli Zhang
    Liwei Zhang
    Xiao Hu
    Xinhui Zheng
    Jiawei Bai
    Yulong Zhang
    Yitong Zhang
    Mingxuan Song
    Yuguo Tang
    [J]. Nature Biomedical Engineering, 2020, 4 : 1150 - 1158