Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2

被引:20
|
作者
Krsihna, B. Vamsi [1 ]
Ahmadsaidulu, Shaik [2 ]
Teja, Surapaneni Sai Tarun [2 ]
Jayanthi, D. [3 ]
Navaneetha, Alluri [4 ]
Reddy, P. Rahul [5 ]
Prakash, M. Durga [2 ]
机构
[1] Koneru Lakshmaih Educ Fdn, Dept ECE, Guntur 522502, Andhra Pradesh, India
[2] Velagapudi Ramakrishna Siddhartha Engn Coll, Dept ECE, Kanuru 520007, Andhra Pradesh, India
[3] Gokaraju Rangaraju Inst Engn & Technol, Dept ECE, Hyderabad 500090, Telangana, India
[4] Mahatma Gandhi Inst Technol, Dept ECE, Hyderabad 500075, Telangana, India
[5] Geethanjali Inst Sci & Technol, Dept ECE, Nellore 524137, Andhra Pradesh, India
关键词
FET; SARS-CoV-2; rGO; Biosensor; Limit of detection; NANOWIRE; TRANSISTOR; PERFORMANCE;
D O I
10.1007/s12633-021-01372-1
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The most affected disease in recent years is Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-COV-2) that is notable as COVID-19. It has been started as a disease in one place and arisen as a pandemic throughout the world. A serious health problem is developed in the lungs due to the effect of this coronavirus. Sometimes it may result in death as a consequence of extensive alveolar damage and progressive respiratory failure. Hence, early detection and appropriate diagnosis of corona virus in patient's body is very essential to save the lives of affected patients This work evolves a Silicon (Si) based label-free electrical device i.e. the reduced graphene oxide field-effect transistor (rGO FET) for SARS-CoV-2 detection. Firstly rGO FET functionalized with SARS-CoV-2 monoclonal antibodies (mAbs). Then the rGO FET characteristic response is observed to detect the antibody-antigen reaction of SARS-CoV-2 with different molar ranges. The developed GFET shows better performance towards the drain current and limit-of-detection (LoD) up to 2E-18 M. Therefore, we believe that an intense response was observed than the earlier developed devices and signifies impressive capability for subsequent implementation in point-of-care (PoC) diagnostic tests.
引用
收藏
页码:5913 / 5921
页数:9
相关论文
共 50 条
  • [1] Design and Development of Graphene FET Biosensor for the Detection of SARS-CoV-2
    B. Vamsi Krsihna
    Shaik Ahmadsaidulu
    Surapaneni Sai Tarun Teja
    D. Jayanthi
    Alluri Navaneetha
    P. Rahul Reddy
    M. Durga Prakash
    [J]. Silicon, 2022, 14 : 5913 - 5921
  • [2] Great enhancement of sensitivity for SARS-CoV-2 detection by integrated graphene FET biosensor using ζ potential modulator
    Yamamoto, Kaori
    Sato, Natsuki
    Sakano, Kiyoji
    Yano, Mamiko
    Ohnishi, Eriko
    Ono, Takao
    Kanai, Yasushi
    Ushiba, Shota
    Miyakawa, Naruto
    Tani, Shinsuke
    Kimura, Masahiko
    Watanabe, Yohei
    Inoue, Koichi
    Tanaka, Hidekazu
    Matsumoto, Kazuhiko
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (03)
  • [3] Ultrasensitive Detection of Dopamine, IL-6 and SARS-CoV-2 Proteins on Crumpled Graphene FET Biosensor
    Hwang, Michael Taeyoung
    Park, Insu
    Heiranian, Mohammad
    Taqieddin, Amir
    You, Seungyong
    Faramarzi, Vahid
    Pak, Angela A.
    Zande, Arend M.
    Aluru, Narayana R.
    Bashir, Rashid
    [J]. ADVANCED MATERIALS TECHNOLOGIES, 2021, 6 (11)
  • [4] Graphene-metasurface-based biosensor for SARS-CoV-2 detection
    Ghosh, Sambit Kumar
    Chaudhuri, Anirban
    Bhattacharyya, Somak
    Pal, Parama
    [J]. HIGH CONTRAST METASTRUCTURES XI, 2022, 12011
  • [5] Graphene Field Effect Biosensor for Concurrent and Specific Detection of SARS-CoV-2 and Influenza
    Kumar, Neelotpala
    Towers, Dalton
    Myers, Samantha
    Galvin, Cooper
    Kireev, Dmitry
    Ellington, Andrew D.
    Akinwande, Deji
    [J]. ACS NANO, 2023, 17 (18) : 18629 - 18640
  • [6] Non-Functionalized Graphene Ribbons FET Biosensor Platform: SARS-CoV-2 Detection on TiO2 Gate Dielectric Windows
    Rufino, Fernando Cesar
    de Almeida, Cassio Roberto
    Sales, Geovana
    Cesar, Rodrigo
    Vidal, Melissa
    Delafiori, Jeany
    de Oliveira, Arthur
    Busanello, Estela
    Siciliano, Rinaldo
    Nicolau, Jose Carlos
    Bertolin, Adriadne
    Salsoso, Rocio
    Marcondes-Braga, Fabiana
    Santos, Thebano
    Larrude, Duniskys
    Gobbi, Angelo
    Costa, Carlos
    Teixeira, Ricardo Cotrin
    Catharino, Rodrigo
    Diniz, Jose Alexandre
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (12) : 18791 - 18804
  • [7] SARS-CoV-2 detection by using graphene FET arrays with a portable microfluidic measurement system
    Yamamoto, Kaori
    Sato, Natsuki
    Sakano, Kiyoji
    Kanai, Yasushi
    Ushiba, Shota
    Miyakawa, Naruto
    Tani, Shinsuke
    Kimura, Masahiko
    Watanabe, Yohei
    Tanaka, Hidekazu
    Matsumoto, Kazuhiko
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (01)
  • [8] A review of electrochemical biosensor application in the detection of the SARS-COV-2
    Jiang, Chunying
    Mu, Xihui
    Du, Bin
    Tong, Zhaoyang
    [J]. MICRO & NANO LETTERS, 2022, 17 (03) : 49 - 58
  • [9] Portable microfluidic impedance biosensor for SARS-CoV-2 detection
    Laleh, Soroush
    Ibarlucea, Bergoi
    Stadtmueller, Marlena
    Cuniberti, Gianaurelio
    Medina-Sanchez, Mariana
    [J]. BIOSENSORS & BIOELECTRONICS, 2023, 236
  • [10] Nonlinear dielectric spectroscopy biosensor for SARS-CoV-2 detection
    Talebipour, Ali
    Ghannad, Amir Hosein
    Sharifi, Elham
    Pirzadeh, Morteza
    Moghadam, Hamed Hasanzadeh
    Saviz, Mehrdad
    Badieirostami, Majid
    Reikandeh, Parham Karimi
    Mobasheri, Hamid
    Faraji-Dana, Reza
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)