Comparison of Cervical Length Measured by Transvaginal Ultrasonography and Bishop Score in Predicting Response to Labor Induction

被引:19
|
作者
Khandelwal R. [1 ]
Patel P. [2 ]
Pitre D. [2 ]
Sheth T. [2 ]
Maitra N. [2 ]
机构
[1] Department of Obstetrics and Gynecology, UCMS College, GTB Hospital, New Delhi
[2] Department of Obstetrics and Gynecology, Medical College, Baroda, Anandpura, Baroda
关键词
Bishop score; Induction active phase interval; Labor induction; Transvaginal cervical length;
D O I
10.1007/s13224-017-1027-y
中图分类号
学科分类号
摘要
Background: This study aims to compare the value of the Bishop score and cervical length measurement by transvaginal ultrasonography in predicting active labor within 6 h, induction-to-delivery interval, and the duration of active labor and to estimate the most useful cutoff points for the two methods. Methods: This is a prospective comparative study of Bishop score and cervical length measured by transvaginal sonography on 62 nulliparous subjects who underwent induction of labor. Results: The Bishop score of the subjects ranged from two to seven (2–7). The mean Bishop in this study population was 4.37 + 1.23. The mean cervical length in this study was 25.59 + 6.07. Bishop score was highly significant (P value < 0.0001) in predicting active phase of labor as compared to cervical length (P = 0.004). The best cutoff value for Bishop score to predict induction of labor within 6 h was more than 4 with sensitivity of 69% and specificity of 79%. Similarly, best cutoff value for cervical length to predict induction of labor within 6 h was less than or equal to 25 mm with sensitivity of 51% and specificity of 70%. Bishop score was more significant (P = 0.001) in predicting induction-to-delivery interval within 12 h as compared to cervical length (P = 0.01). Conclusion: The Bishop score was superior in predicting the response to induction as compared to the cervical length measured by transvaginal ultrasonography. © 2017, Federation of Obstetric & Gynecological Societies of India.
引用
收藏
页码:51 / 57
页数:6
相关论文
共 50 条
  • [31] Body mass index, Bishop score, and sonographic measurement of the cervical length as predictors of successful labor induction in twin gestations
    Park, Kyo-Hoon
    Hong, Joon-Seok
    Kang, Woong-Sun
    Shin, Dong-Myung
    Kim, Shi-Nae
    JOURNAL OF PERINATAL MEDICINE, 2009, 37 (05) : 519 - 523
  • [32] The value of the cervical score in predicting successful outcome of labor induction
    Williams, MC
    Krammer, J
    OBrien, WF
    OBSTETRICS AND GYNECOLOGY, 1997, 90 (05): : 784 - 789
  • [33] Transvaginal versus transperineal ultrasonography: A blinded comparison in the assessment of cervical length at midgestation
    Kurtzman, JT
    Goldsmith, LJ
    Gall, SA
    Spinnato, JA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 179 (04) : 852 - 857
  • [34] Comparison of transabdominal and transvaginal ultrasonography for the assessment of cervical length in the third trimester of pregnancy
    Tsakiridis, Ioannis
    Mamopoulos, Apostolos
    Athanasiadis, Apostolos
    Dagklis, Themistoklis
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2019, 58 (06): : 784 - 787
  • [35] Comparison of ultrasonographic cervical length to bishop score in determining the administration of prostaglandin for pre-induction cervical ripening in term nulliparas
    Shin, Dong-Myung
    Park, Kyo Hoon
    Hong, Joon-Seok
    Kang, Woong Sun
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (06) : S95 - S95
  • [36] Correlation between lower uterine wall thickness measured by transabdominal ultrasonography and cervical length measured by transvaginal ultrasonography in Thai pregnant women
    Woraboot, Wanitchar
    Wanitpongpan, Prapat
    Phaophan, Amprapha
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2019, 82 (01) : 50 - 54
  • [37] Bishop score and the outcome of labor induction with misoprostol
    Szczesny, Witold
    Kjollesdal, Moyfrid
    Karlsson, Bengt
    Nielsen, Sven
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (05) : 579 - 582
  • [38] Changes in cervical nitric oxide concentration correlate with bishop score and cervical length modifications in prostaglandin E2-mediated induction of labor
    Chiossi, G
    Verocchi, G
    Venturini, P
    Facchinetti, F
    JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2006, 13 (03) : 203 - 208
  • [39] Changes in Cervical Nitric Oxide Concentration Correlate With Bishop Score and Cervical Length Modifications in Prostaglandin E2-Mediated Induction of Labor
    Giuseppe Chiossi
    Gianluca Verocchi
    Paolo Venturini
    Fabio Facchinetti
    The Journal of the Society for Gynecologic Investigation: JSGI, 2006, 13 : 203 - 208
  • [40] Can measurement of cervical length, fetal head position and posterior cervical angle be an alternative method to Bishop score in the prediction of successful labor induction?
    Gokturk, Umut
    Cavkaytar, Sabri
    Danisman, Nuri
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2015, 28 (11): : 1360 - 1365