Kinetic and enzymatic adsorption model in a recirculation hollow-fibre bioreactor

被引:0
|
作者
E. Jurado
F. Camacho
G. Luzón
J. M. Vicaria
机构
[1] Universidad de Granada,Departamento Ingeniería Química, Facultad Ciencias
来源
关键词
Enzyme adsorption; Hollow-fibre bioreactor; Lactose hydrolysis; Glucose–fructose isomerization;
D O I
暂无
中图分类号
学科分类号
摘要
A general procedure has been developed to model the behaviour of enzymatic reactions in a membrane bioreactor. This procedure unifies the kinetics of the reaction and the adsorption of the enzyme or enzymatic complexes on the membrane, enabling the selection of the most appropriate kinetic model. The general procedure proposed has been particularized and applied to experimental results obtained with two enzymatic reactions carried out in a hollow-fibre reactor, enzymatic hydrolysis of lactose by β-galactosidase and glucose–fructose isomerization by glucose isomerase. The application of the general model has allowed us to determine the mechanism of the reaction for both kinetic reactions, assuming the adsorption of the enzymatic complex EGa for lactose hydrolysis and the adsorption of the free enzyme onto the membrane for glucose–fructose isomerization.
引用
收藏
页码:27 / 36
页数:9
相关论文
共 50 条
  • [31] The effect of cake and fibre properties on flux declines in hollow-fibre microfiltration membranes
    Carroll, T
    JOURNAL OF MEMBRANE SCIENCE, 2001, 189 (02) : 167 - 178
  • [32] Serum-free culture of primary human hepatocytes in a miniaturized hollow-fibre membrane bioreactor for pharmacological in vitro studies
    Luebberstedt, Marc
    Mueller-Vieira, Ursula
    Biemel, Klaus M.
    Darnell, Malin
    Hoffmann, Stefan A.
    Knoespel, Fanny
    Woenne, Eva C.
    Knobeloch, Daniel
    Nuessler, Andreas K.
    Gerlach, Joerg C.
    Andersson, Tommy B.
    Zeilinger, Katrin
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2015, 9 (09) : 1017 - 1026
  • [33] Improved hollow-fibre membranes for dye-affinity chromatography
    Wolman, FJ
    Smolko, EE
    Cascone, O
    Grasselli, M
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (01) : 45 - 51
  • [34] Protein transport in packed bed ultrafiltration hollow-fibre bioreactors
    Koska, J
    Bowen, BD
    Piret, JM
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (14) : 2251 - 2263
  • [35] Hollow-fibre Based Microextraction and Voltammetric Determination of Vanillylmandelic Acid
    Hrdlicka, Vojtech
    Barek, Jin
    Navratil, Tomas
    XXXVII MODERNI ELEKTROCHEMICKE METODY, 2017, : 66 - 70
  • [36] Innovating dialysis through computational modelling of hollow-fibre haemodialysers
    Sinha, Ruhit
    Rocco, Michael V.
    Daeihagh, Pirouz
    Staples, Anne E.
    NATURE REVIEWS NEPHROLOGY, 2024, 20 (05) : 269 - 270
  • [37] Leakage across hollow-fibre membranes in oxygenators: a pilot study
    Visser, C.
    de Jong, D. S.
    PERFUSION-UK, 1996, 11 (05): : 389 - 393
  • [38] Preparation of hollow-fibre composite carbon-zeolite membranes
    Smith, S.P.J.
    Linkov, V.M.
    Sanderson, R.D.
    Petrik, L.F.
    O'Connor, C.T.
    Keiser, K.
    Microporous Materials, 1995, 4 (05):
  • [39] A hollow-fibre column system to effectively prepare washed platelets
    Tanaka, S.
    Hayashi, T.
    Sugaya, S.
    Osabe, M.
    Ueno, Y.
    Tani, Y.
    Hirayama, F.
    VOX SANGUINIS, 2015, 109 (03) : 239 - 247
  • [40] Improved protein refolding using hollow-fibre membrane dialysis
    West, SM
    Chaudhuri, JB
    Howell, JA
    BIOTECHNOLOGY AND BIOENGINEERING, 1998, 57 (05) : 590 - 599