Quantitative multi-modality imaging analysis of a fully bioresorbable stent: a head-to-head comparison between QCA, IVUS and OCT

被引:0
|
作者
Juan Luis Gutiérrez-Chico
Patrick W. Serruys
Chrysafios Girasis
Scot Garg
Yoshinobu Onuma
Salvatore Brugaletta
Héctor García-García
Gerrit-Anne van Es
Evelyn Regar
机构
[1] Erasmus Medical Centre,
[2] Cardialysis BV,undefined
来源
The International Journal of Cardiovascular Imaging | 2012年 / 28卷
关键词
Coronary angiography; Poly(lactide); Quantitative coronary angiography; Intravascular ultrasound; Tomography; Optical coherence;
D O I
暂无
中图分类号
学科分类号
摘要
The bioresorbable vascular stent (BVS) is totally translucent and radiolucent, leading to challenges when using conventional invasive imaging modalities. Agreement between quantitative coronary angiography (QCA), intravascular ultrasound (IVUS) and optical coherence tomography (OCT) in the BVS is unknown. Forty five patients enrolled in the ABSORB cohort B1 study underwent coronary angiography, IVUS and OCT immediately post BVS implantation, and at 6 months. OCT estimated stent length accurately compared to nominal length (95% CI of the difference: −0.19; 0.37 and −0.15; 0.47 mm2 for baseline and 6 months, respectively), whereas QCA incurred consistent underestimation of the same magnitude at both time points (Pearson correlation = 0.806). IVUS yielded low accuracy (95% CI of the difference: 0.77; 3.74 and −1.15; 3.27 mm2 for baseline and 6 months, respectively), with several outliers and random variability test–retest. Minimal lumen area (MLA) decreased substantially between baseline and 6 months on QCA and OCT and only minimally on IVUS (95% CI: 0.11; 0.42). Agreement between the different imaging modalities is poor: worst agreement Videodensitometry-IVUS post-implantation (ICCa 0.289); best agreement IVUS-OCT at baseline (ICCa 0.767). All pairs deviated significantly from linearity (P < 0.01). Passing-Bablok non-parametric orthogonal regression showed constant and proportional bias between IVUS and OCT. OCT is the most accurate technique for measuring stent length, whilst QCA incurs systematic underestimation (foreshortening) and solid state IVUS incurs random error. Volumetric calculations using solid state IVUS are therefore not reliable. There is poor agreement for MLA estimation between all the imaging modalities studied, including IVUS-OCT, hence their values are not interchangeable.
引用
收藏
页码:467 / 478
页数:11
相关论文
共 50 条
  • [21] Grading of aortic stenosis severity: a head-to-head comparison between cardiac magnetic resonance imaging and echocardiography
    Mantini, Cesare
    Di Giammarco, Gabriele
    Pizzicannella, Jacopo
    Gallina, Sabina
    Ricci, Fabrizio
    D'Ugo, Emilia
    Marchetti, Marziale
    Cotroneo, Antonio Raffaele
    Ahmed, Nauman
    Bucciarelli-Ducci, Chiara
    Tartaro, Armando
    De Caterina, Raffaele
    RADIOLOGIA MEDICA, 2018, 123 (09): : 643 - 654
  • [22] Grading of aortic stenosis severity: a head-to-head comparison between cardiac magnetic resonance imaging and echocardiography
    Cesare Mantini
    Gabriele Di Giammarco
    Jacopo Pizzicannella
    Sabina Gallina
    Fabrizio Ricci
    Emilia D’Ugo
    Marziale Marchetti
    Antonio Raffaele Cotroneo
    Nauman Ahmed
    Chiara Bucciarelli-Ducci
    Armando Tartaro
    Raffaele De Caterina
    La radiologia medica, 2018, 123 : 643 - 654
  • [23] Head-to-head comparison of visual and quantitative assessment of transmural extent of infarction on contrast-enhanced magnetic resonance imaging
    Schuijf, JD
    Bax, JJ
    Kaandorp, TAM
    Lamb, HJ
    Van der Geest, RJ
    Viergever, ER
    Van der Wall, EE
    de Roos, A
    EUROPEAN HEART JOURNAL, 2004, 25 : 53 - 53
  • [24] Multi-modality imaging-monitored creation of rat orthotopic pancreatic head cancer with obstructive jaundice
    Bai, Zhibin
    Shi, Yaoping
    Wang, Jianfeng
    Qiu, Longhua
    Teng, Gaojun
    Zhang, Feng
    Yang, Xiaoming
    ONCOTARGET, 2017, 8 (33) : 54277 - 54284
  • [25] Head-to-Head Comparison of Automated versus Manual Detection for Lumen Contour and Stent Struts in Optical Coherence Tomography Analysis
    Otagiri, Kyuhachi
    Kitahara, Hideki
    Yaguchi, Tomonori
    Tanaka, Shigemitsu
    Okada, Kozo
    Kobayashi, Yuhei
    Miura, Takashi
    Ebisawa, Soichiro
    Miyashita, Yusuke
    Yock, Paul
    Fitzgerald, Peter J.
    Ikeda, Uichi
    Honda, Yasuhiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B116 - B116
  • [26] Head-to-head comparison between SPECT myocardial perfusion imaging and non-invasive angiography with multi-slice CT in asymptomatic diabetics
    Scholte, A. J. H. A.
    Schuijf, J. D.
    Kharagjitsingh, A. V.
    Stokkel, M. P.
    Jukema, J. W.
    Wall Van der, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 288 - 288
  • [27] Multi-Level Multi-Modality Fusion Radiomics: Application to PET and CT Imaging for Prognostication of Head and Neck Cancer
    Lv, Wenbing
    Ashrafinia, Saeed
    Ma, Jianhua
    Lu, Lijun
    Rahmim, Arman
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (08) : 2268 - 2277
  • [28] RANDOMIZED COMPARISON OF ABSORB BIORESORBABLE VASCULAR SCAFFOLD AND MIRAGE MICROFIBER SIROLIMUS ELUTING SCAFFOLD USING MULTI-MODALITY IMAGING
    Santoso, Teguh
    Liew, Huong Bang
    Tenekecioglu, Erhan
    Costa, Ricardo
    Chamie, Daniel
    Su, Solomon
    Abizaid, Alexandre
    Bourantas, Christos
    Torii, Ryo
    Onuma, Yoshinobu
    Serruys, Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B174 - B174
  • [29] Head-to-head comparison between contrast-enhanced magnetic resonance imaging and dobutamine magnetic resonance imaging in men with ischemic cardiomyopathy
    Kaandorp, TAM
    Bax, JJ
    Schuijf, JD
    Viergever, EP
    van der Wall, EE
    de Roos, A
    Lamb, HJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (12): : 1461 - 1464
  • [30] Multi-modality analysis supports APOBEC as a major source of mutations in head and neck squamous cell carcinoma
    Faden, Daniel L.
    Thomas, Sean
    Cantalupo, Paul G.
    Agrawal, Nishant
    Myers, Jeffrey
    DeRisi, Joseph
    ORAL ONCOLOGY, 2017, 74 : 8 - 14