A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience

被引:0
|
作者
Stéphanie Pitre
Laurent Ménard
Marcel Ricard
Maurice Solal
Jean-Rémi Garbay
Yves Charon
机构
[1] Institut de Physique Nucléaire,Groupe Modélisation Physique Interfaces Biologie, FR CNS 2438 "Matière et systèmes complexes"
[2] Université Paris 7,Department of Medical Physics
[3] Institut G. Roussy,Department of General Surgery
[4] U494 INSERM,undefined
[5] Institut G. Roussy,undefined
关键词
Hand-held gamma camera; Intra-operative imaging; Radio-guided surgery; Sentinel lymph node detection; Breast cancer;
D O I
暂无
中图分类号
学科分类号
摘要
Improvements in the specificity of radiopharmaceutical compounds have been paralleled by an upsurge of interest in developing small detectors to assist surgeons in localizing tumour tissue during surgery. This study reports the main technical features and physical characteristics of a new hand-held gamma camera dedicated to accurate and real-time intra-operative imaging. First clinical experience is also reported. The POCI (Per-operative Compact Imager) camera consists of a head module composed of a high-resolution interchangeable lead collimator and a CsI(Na) crystal plate optically coupled to an intensified position-sensitive diode. The current prototype has a 40-mm diameter field of view, an outer diameter of 9.5 cm, a length of 9 cm and a weight of 1.2 kg. Overall detector imaging characteristics were evaluated by technetium-99m phantom measurements. Three patients with breast cancer previously scheduled to undergo sentinel lymph node detection were selected for the preliminary clinical experience. Preoperative images of the lymphatic basin obtained using the POCI camera were compared with conventional transcutaneous explorations using a non-imaging gamma probe. The full-width at half-maximum (FWHM) spatial resolution was investigated in both air and scattering medium; when the phantom was placed in contact with the collimator, the POCI camera exhibited a 3.2 mm FWHM. The corresponding sensitivity was 290 cps/MBq. The preliminary clinical results showed that POCI was able to predict the number and location of all SLNs. In one case, two deep radioactive nodes missed by the gamma probe were detected on the intra-operative images. This very initial experience demonstrates that the physical performance of the POCI camera is adequate for radio-guided surgery. These results are sufficiently encouraging to prompt further evaluation studies designed to determine the specific and optimal clinical role of intra-operative imaging devices.
引用
收藏
页码:339 / 343
页数:4
相关论文
共 50 条
  • [1] A hand-held imaging probe for radio-guided surgery:: physical performance and preliminary clinical experience
    Pitre, S
    Ménard, L
    Ricard, M
    Solal, M
    Garbay, JR
    Charon, Y
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (03) : 339 - 343
  • [2] Phantom study of a new hand-held γ-imaging probe for radio-guided surgery
    Ferretti, Alice
    Chondrogiannis, Sotirios
    Marcolongo, Adriano
    Rubello, Domenico
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (01) : 86 - 90
  • [3] The Utility of the Portable Hand-Held Gamma Camera in Minimally Invasive Radio-Guided Parathyroidectomy
    Mut Dolera, T.
    Tembl Ferrairo, A.
    Romero Otero, M.
    Ferrer Ramirez, M. J.
    Saiz Monfort, V.
    Bermell Carrion, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S204 - S204
  • [4] Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera
    Soluri, A.
    Trotta, C.
    Scopinaro, F.
    Tofani, A.
    D'Alessandria, C.
    Pasta, V.
    Stella, S.
    Massari, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3): : 366 - 371
  • [5] The Value of Early SPECT/CT and Hand-Held γ-Camera in Radio-Guided Surgery A Case of a Hard-To-Locate Parathyroid Adenoma
    Garcia-Talavera, Paloma
    Luisa Gonzalez-Selma, Maria
    Angeles Ruiz, Maria
    Gamazo, Claudia
    Sainz-Esteban, Aurora
    Gabriel Villanueva, Juan
    Olmos, Roberto
    [J]. CLINICAL NUCLEAR MEDICINE, 2014, 39 (11) : 1009 - 1011
  • [6] A hand-held beta imaging probe for FDG
    Bipin Singh
    Brendan C. Stack
    Samta Thacker
    Valeriy Gaysinskiy
    Twyla Bartel
    Val Lowe
    Steven Cool
    Gerald Entine
    Vivek Nagarkar
    [J]. Annals of Nuclear Medicine, 2013, 27 : 203 - 208
  • [7] A hand-held beta imaging probe for FDG
    Singh, Bipin
    Stack, Brendan C., Jr.
    Thacker, Samta
    Gaysinskiy, Valeriy
    Bartel, Twyla
    Lowe, Val
    Cool, Steven
    Entine, Gerald
    Nagarkar, Vivek
    [J]. ANNALS OF NUCLEAR MEDICINE, 2013, 27 (03) : 203 - 208
  • [8] The Tumor Resection Camera (TReCam), a multipixel imaging probe for radio-guided surgery
    Netter, E.
    Pinot, L.
    Menard, L.
    Duval, M. A.
    Janvier, B.
    Lefebvre, F.
    Siebert, R.
    Charon, Y.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2573 - 2576
  • [9] The Tumor Resection Camera (TReCam), an intraoperative imaging probe for radio-guided surgery
    Netter, E.
    Pinot, L.
    Duval, M.
    Janvier, B.
    Lefebvre, F.
    Menard, L.
    Siebert, R.
    Charon, Y.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S309 - S309
  • [10] Directional probe for radio-guided surgery: A pilot study
    Massari, Roberto
    Ucci, Antonio
    D'Elia, Annunziata
    Campisi, Costantino
    Bertani, Emilio
    Soluri, Alessandro
    [J]. MEDICAL PHYSICS, 2018, 45 (02) : 622 - 628