Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera

被引:11
|
作者
Soluri, A. [1 ,2 ]
Trotta, C. [1 ,2 ]
Scopinaro, F. [1 ,3 ]
Tofani, A. [4 ]
D'Alessandria, C. [3 ,4 ]
Pasta, V. [3 ]
Stella, S. [5 ]
Massari, R. [1 ,2 ]
机构
[1] CNR, Inst Biomed Engn, I-00016 Rome, Italy
[2] Li Tech Srl, Udine, Italy
[3] Univ Roma La Sapienza, Rome, Italy
[4] Univ Hosp S Andrea, Rome, Italy
[5] Univ G Dannunzio, Dept Gen Surg, Chieti, Italy
关键词
gamma ray imager; scintillation detector; position-sensitive photomultiplier tube; portable gamma camera;
D O I
10.1016/j.nima.2007.09.031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since 1997, our group of Physics together with Nuclear Physicians studies imaging probes (IP), hand-held, high-resolution gamma cameras for radio-guided surgery (RGS). Present work is aimed to verify the usefulness of two updated IP in different surgical operations. Forty patients scheduled for breast cancer sentinel node (SN) biopsy, five patients with nodal recurrence of thyroid cancer, seven patients with parathyroid adenomas, five patients with neuroendocrine tumours (NET), were operated under the guide of IP. We 2 used two different IP with field of view of 1 and 4in.(2), respectively and intrinsic spatial resolution of about 2mm. Radioisotopes were Tc-99m, I-123 and In-111. The 1 in.(2) IP detected SN in all the 40 patients and more than one node in 24, whereas anger camera (AC) failed locating SN in four patients and detected true positive second nodes in only nine patients. The 4 in.(2) IP was used for RGS of thyroid, parathyroid and NETs. It detected eight latero-cervical nodes. In the same patients, AC detected five invaded nodes. Parathyroid adenomas detected by IP were 10 in 7 patients, NET five in five patients. One and 4 in.(2) IPs showed usefulness in all operations. Initial studies on SN biopsy were carried out on small series of patients to validate IP and to demonstrate the effectiveness and usefulness of IP alone or against conventional probes. We propose the use of the IP as control method for legal documentation and surgeon strategy guide before and after lesion(s) removal. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 50 条
  • [1] High-resolution hand-held gamma camera
    MacDonald, LR
    Patt, BE
    Iwanczyk, JS
    Yamaguchi, Y
    McElroy, D
    Hoffman, EJ
    Aarsvold, JN
    Mintzer, RA
    Alazraki, NP
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 242 - 253
  • [2] A high resolution hand-held gamma camera for cancer surgery.
    Pitre, S
    Menard, L
    Charon, Y
    Solal, M
    Ricard, M
    Laniece, P
    Mastrippolito, R
    Valentin, L
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 202P - 202P
  • [3] High-resolution, hand-held camera for sentinel-node detection
    Scopinaro, Francesco
    Tofani, Anna
    di Santo, Gianpaolo
    Di Pietro, Barbara
    Lombardi, Augusto
    Lo Russo, Marzia
    Soluri, Alessandro
    Massari, Roberto
    Trotta, Carlo
    Amanti, Claudio
    [J]. CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2008, 23 (01) : 43 - 52
  • [4] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Domenico Rubello
    Giuliano Mariani
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 162 - 164
  • [5] Hand-held gamma probe or hand-held miniature gamma camera for minimally invasive parathyroidectomy: competition, evolution or synergy?
    Rubello, Domenico
    Mariani, Giuliano
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 162 - 164
  • [6] Phantom study of a new hand-held γ-imaging probe for radio-guided surgery
    Ferretti, Alice
    Chondrogiannis, Sotirios
    Marcolongo, Adriano
    Rubello, Domenico
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (01) : 86 - 90
  • [7] Imaging performance of a prototype hand-held gamma camera for surgical use
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Shirahata, T
    Orskaug, T
    [J]. RADIOLOGY, 2001, 221 : 127 - 127
  • [8] Polarized light imaging with a hand-held camera
    Ramella-Roman, JC
    Lee, K
    Prahl, SA
    Jacques, SL
    [J]. SARATOV FALL MEETING 2002: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE IV, 2002, 5068 : 284 - 293
  • [9] A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience
    Stéphanie Pitre
    Laurent Ménard
    Marcel Ricard
    Maurice Solal
    Jean-Rémi Garbay
    Yves Charon
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 339 - 343
  • [10] A hand-held hybrid gamma-near-infrared fluorescence imaging camera
    Jambi, Layal
    Lees, John
    Bugby, Sarah
    Alqahtani, Mohammed
    Bhatia, Bahadar
    McKnight, William
    Dawood, Numan
    Ng, Aik
    Perkins, Alan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58