Accuracy optimization method of ultrasonic power measurement system based on acousto-optic effect

被引:0
|
作者
Ben Shen
Baoshan Zeng
Xiaojian Liu
Chenzefang Feng
Zhou Hu
Jianxiong Hu
Fulong Zhu
机构
[1] Huazhong University of Science and Technology,School of Mechanical Science and Engineering
[2] Hubei Province,undefined
来源
Optical Review | 2021年 / 28卷
关键词
Ultrasonic power; Acousto-optic effect; Accuracy optimization;
D O I
暂无
中图分类号
学科分类号
摘要
Ultrasonic wave has been widely used in the medical field because of its special physical properties. However, it might cause health risk for the human body if the power is inaccurately measured. As a noncontact measurement method, the acousto-optic method gives a lower uncertainty than the mechanical and contact method. To improve the accuracy of ultrasonic power measurement system based on the acousto-optic effect, we optimized the image processing algorithms by adjusting the threshold of binarization, optimizing the centroid coordinates calculation method, and rectangular areas division method. The results showed that the measurement of uncertainty of the acousto-optic method was lower than the radiation balance method, and the accuracy of the measurement system based on the acousto-optic effect was improved from 79.59 to 96.17% after algorithm optimization.
引用
收藏
页码:207 / 214
页数:7
相关论文
共 50 条
  • [31] MEASUREMENT OF THE MUTUAL SPECTRAL POWER DENSITY WITH THE AID OF ACOUSTO-OPTIC PROCESSORS.
    Bokov, L.A.
    Krakovskii, V.A.
    Pugovkin, A.V.
    Radio Engineering and Electronic Physics (English translation of Radiotekhnika i Elektronika), 1982, 27 (06): : 115 - 120
  • [32] Phase measurement errors in acousto-optic processor in the case of various power levels
    Jodlowski, L
    Bobrowicz, R
    ACOUSTO-OPTICS AND APPLICATIONS III, 1998, 3581 : 231 - 236
  • [33] Fiber based acousto-optic filters
    Kim, Byoung Yoon
    Yun, Seok Hyun
    Conference on Optical Fiber Communication, Technical Digest Series, 1999,
  • [34] New modulation method in acousto-optic spectrometers
    Pustovoit, V., I
    QUANTUM ELECTRONICS, 2019, 49 (08) : 707 - 716
  • [35] Acousto-optic system for frequency and phase demodulation
    Hicks, M
    Reeve, CD
    ADVANCES IN OPTICAL INFORMATION PROCESSING VII, 1996, 2754 : 75 - 82
  • [36] Ultrasonic frequency coordination relation of the acousto-optic tunable filter
    Li Shi-Jun
    Ren Yu
    Lu Jun
    Cai Hong-Xing
    ACTA PHYSICA SINICA, 2011, 60 (05)
  • [37] Application of acousto-optic actuator in holographic system
    Ling, FR
    Wang, B
    ADVANCED OPTICAL STORAGE TECHNOLOGY, 2002, 4930 : 372 - 376
  • [38] Ultrasonic transducer and mode-conversion system for optical fiber acousto-optic device
    Liu, Guo-Xiang
    Hu, Li
    Ye, Kun-Zhen
    Yadian Yu Shengguang/Piezoelectrics and Acoustooptics, 2006, 28 (03): : 274 - 277
  • [39] A dedicated acoustic/acousto-optic imaging system
    Selb, J
    Pottier, L
    Lévêque-Fort, S
    Boccara, AC
    HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 : 89 - 95
  • [40] Measurement of acoustic radiation pattern in an acousto-optic modulator
    Gies, DT
    Poon, TC