Multiple immunoassay systems are negatively interfered by circulating cardiac troponin I autoantibodies

被引:0
|
作者
Gusheng Tang
Yu Wu
Weiguo Zhao
Qian Shen
机构
[1] Second Military Medical University,Department of Laboratory Medicine, Changhai Hospital
[2] 94th Hospital of the Chinese People’s Liberation Army,Department of Laboratory Medicine
来源
Clinical and Experimental Medicine | 2012年 / 12卷
关键词
Negative interference; cTnI autoantibody; AMI; Immunoassay systems;
D O I
暂无
中图分类号
学科分类号
摘要
Circulating cardiac troponin I (cTnI) autoantibodies have recently been detected in more and more patients with myocardial injury. In the present study, a total of 121 patients with acute myocardial infarction (AMI) were screened for cTnI autoantibodies using an indirect ELISA. Positive results were further confirmed by Western blot analysis. As a result, 13 autoantibody-positive sera were identified, in which cTnI values detected by different immunoassay systems are very different. Further evaluation revealed low recovery in one of the 13 samples with the Access 2 system (Beckman Coulter, 2^ generation), one low and one moderate recovery sample with Architect i2000 (Abbott), one low and two moderate with AxSYM (Abbott), two low and three moderate with Dimension Xpand (Dade Behring, 2^ generation), and four low and one moderate with Vidas (bioMérieux). Our work demonstrates that circulating cTnI autoantibodies occur in part of patients with AMI and, for the first time to our knowledge, shows that these autoantibodies can result in considerable negative interference in all the five commonly used cTnI immunoassay systems, which may lead to incorrect diagnoses and following treatments. The indirect ELISA established in our laboratory is suitable for a rapid preliminary screening for cTnI autoantibody in clinical work.
引用
收藏
页码:47 / 53
页数:6
相关论文
共 50 条
  • [31] Circulating cardiac troponin I in trauma patients without cardiac contusion
    A. R. Edouard
    J. F. Benoist
    C. Cosson
    O. Mimoz
    A. Legrand
    K. Samii
    Intensive Care Medicine, 1998, 24 : 569 - 573
  • [32] Anti-Cardiac Troponin Autoantibodies Are Specific to the Conformational Epitopes Formed by Cardiac Troponin.I and Troponin T in the Ternary Troponin Complex
    Vylegzhanina, Alexandra V.
    Kogan, Alexander E.
    Katrukha, Ivan A.
    Antipova, Olga V.
    Kara, Andrey N.
    Bereznikova, Anastasia V.
    Koshkina, Ekaterina V.
    Katrukha, Alexey G.
    CLINICAL CHEMISTRY, 2017, 63 (01) : 343 - 350
  • [33] Alkaline phosphatase in serum samples interfered in Stratus® myoglobin and cardiac troponin I immunoassays.
    Datta, P
    CLINICAL CHEMISTRY, 1999, 45 (06) : A137 - A137
  • [34] The role of autoantibodies against cardiac troponin I in autoimmune dilated cardiomyopathy
    Nishio, R
    Matsumori, A
    Okazaki, T
    Tanaka, Y
    Mitsuiye, T
    Mizoguchi, A
    Hiai, H
    Minato, N
    Honjo, T
    JOURNAL OF CARDIAC FAILURE, 2004, 10 (04) : S56 - S56
  • [35] Autoantibodies against cardiac troponin I in patients with congestive heart failure
    Duengen, Hans-Dirk
    Platzeck, Maria
    Vollert, Joern
    Searle, Julia
    Mueller, Christian
    Reiche, Janett
    Mehrhof, Felix
    Mueller, Reinhold
    Moeckel, Martin
    EUROPEAN JOURNAL OF HEART FAILURE, 2010, 12 (07) : 668 - 675
  • [36] Autoantibodies to cardiac troponin I in patients with idiopathic dilated and ischemic cardiomyopathy
    Shmilovich, Haim
    Danon, Asaf
    Binah, Ofer
    Roth, Arie
    Chen, Gerald
    Wexler, Dov
    Keren, Gad
    George, Jacob
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 117 (02) : 198 - 203
  • [37] Novel sensitive cardiac troponin I immunoassay free from troponin I-specific autoantibody interference
    Savukoski, Tanja
    Jacobino, Jenna
    Laitinen, Paivi
    Lindahl, Bertil
    Venge, Per
    Ristiniemi, Noora
    Wittfooth, Saara
    Pettersson, Kim
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (07) : 1041 - 1048
  • [38] Coprevalence of Autoantibodies to Cardiac Troponin I and T in Normal Blood Donors
    Adamczyk, Maciej
    Brashear, R. Jeffrey
    Mattingly, Phillip G.
    CLINICAL CHEMISTRY, 2010, 56 (04) : 676 - 677
  • [39] Development of an automated quantitative latex immunoassay for cardiac troponin I in serum
    Ash, J
    Baxevanakis, G
    Bilandzic, L
    Shin, H
    Kadijevic, L
    CLINICAL CHEMISTRY, 2000, 46 (09) : 1521 - +
  • [40] An automated immunoassay for determination of cardiac troponin I in serum evaluated.
    Panteghini, M
    Bonora, R
    Pagani, F
    CLINICAL CHEMISTRY, 1996, 42 (06) : 378 - 378