Observation of significant Doppler shift in deuterium-deuterium neutron energy caused by neutral beam injection in the large helical device

被引:8
|
作者
Sangaroon, S. [1 ,2 ]
Ogawa, K. [1 ,3 ]
Isobe, M. [1 ,3 ]
Kobayashi, M. I. [1 ,3 ]
Fujiwara, Y. [1 ]
Kamio, S. [1 ]
Yamaguchi, H. [1 ]
Seki, R. [1 ]
Nuga, H. [1 ]
Takada, E. [4 ]
Murakami, S. [5 ]
Zhong, G. Q. [6 ]
Osakabe, M. [1 ,3 ]
机构
[1] Natl Inst Nat Sci, Natl Inst Fus Sci, 322-6 Oroshi Cho, Toki 5095292, Japan
[2] Mahasarakham Univ, Fac Sci, Dept Phys, Maha Sarakham 44150, Thailand
[3] SOKENDAI, Grad Univ Adv Studies, 322-6 Oroshi Cho, Toki 5095292, Japan
[4] Toyama Coll, Natl Inst Technol, 13 Hongo Machi, Toyama, Toyama 9398630, Japan
[5] Kyoto Univ, Dept Nucl Engn, Kyoto 6158540, Japan
[6] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
来源
AAPPS BULLETIN | 2022年 / 32卷 / 01期
关键词
Doppler effect; Compact neutron emission spectrometer; Large helical device; Liquid scintillator; Neutral beam heating;
D O I
10.1007/s43673-022-00036-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The compact neutron emission spectrometer (CNES) having a tangential sightline was installed to observe a significant Doppler shift of the neutron energy due to the high-energy tangential neutral beam (NB) injections in the Large Helical Device (LHD) for understanding of the energy distribution of fast-ion. The CNES is based on a 1-inch diameter and 1-inch height EJ301 liquid scintillator coupled with a conventional 1-inch photomultiplier tube. The histogram of the integrated pulse signal (Qtotal) during different NBs heating phases measured by the CNES shows that the edge of Qtotal changes depending on NB directions. Using the simple derivative unfolding technique, the neutron energy spectra were unfolded from the measured Qtotal histogram. Peaks of the neutron energy shift to 2.0 MeV, 2.42 MeV, and 3.0 MeV according to the injection direction of NBs. The obtained neutron energy is almost consistent with the virgin deuterium-deuterium neutron energy evaluated by the simple two-body kinematics considering the sightline of CNES, NB injection angle, and NB injection energy.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Fusion neutron production with deuterium neutral beam injection and enhancement of energetic-particle physics study in the large helical device
    Isobe, M.
    Ogawa, K.
    Nishitani, T.
    Pu, N.
    Kawase, H.
    Seki, R.
    Nuga, H.
    Takada, E.
    Murakami, S.
    Suzuki, Y.
    Yokoyama, M.
    Osakabe, M.
    [J]. NUCLEAR FUSION, 2018, 58 (08)
  • [2] Regression Approach for Acquiring a Quantitative Guidance toward Updating the Deuterium-Deuterium Fusion Neutron Emission Rate in the Large Helical Device
    Ogawa, Kunihiro
    Yokoyama, Masayuki
    Isobe, Mitsutaka
    [J]. PLASMA AND FUSION RESEARCH, 2020, 15
  • [3] Regression Approach for Acquiring a Quantitative Guidance toward Updating the Deuterium-Deuterium Fusion Neutron Emission Rate in the Large Helical Device
    Ogawa, Kunihiro
    Yokoyama, Masayuki
    Isobe, Mitsutaka
    [J]. Plasma and Fusion Research, 2020, 15 : 120208 - 1
  • [4] First Results of Deuterium Beam Operation on Neutral Beam Injectors in the Large Helical Device
    Ikeda, K.
    Tsumori, K.
    Kisaki, M.
    Nakano, H.
    Nagaoka, K.
    Osakabe, M.
    Kamio, S.
    Fujiwara, Y.
    Haba, Y.
    Takeiri, Y.
    [J]. PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [5] A study of beam ion and deuterium-deuterium fusion-born triton transports due to energetic particle-driven magnetohydrodynamic instability in the large helical device deuterium plasmas
    Ogawa, K.
    Isobe, M.
    Nuga, H.
    Kamio, S.
    Fujiwara, Y.
    Kobayashi, M., I
    Sangaroon, S.
    Takada, E.
    Seki, R.
    Yamaguchi, H.
    Murakami, S.
    Jo, J.
    Osakabe, M.
    [J]. NUCLEAR FUSION, 2021, 61 (09)
  • [6] Neutron Incident Angle and Energy Distribution at Vacuum Vessel for Beam-Injected Deuterium Plasmas in the Large Helical Device
    Sugiyama, Shota
    Matsuura, Hideaki
    Goto, Takuya
    [J]. PLASMA AND FUSION RESEARCH, 2016, 11 (Specialissue1)
  • [7] MEASUREMENT OF THE FRACTIONAL THERMONUCLEAR NEUTRON YIELD DURING DEUTERIUM NEUTRAL-BEAM INJECTION INTO DEUTERIUM PLASMAS
    LOUGHLIN, MJ
    VANBELLE, P
    HAWKES, NP
    JARVIS, ON
    SADLER, G
    SYME, DB
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (01): : 184 - 191
  • [8] NEUTRON TIME BEHAVIOR DUE TO DEUTERIUM NEUTRAL BEAM INJECTION INTO A HYDROGEN PLASMA
    ENGLAND, AC
    FOWLER, RH
    HOWE, HC
    MIHALCZO, JT
    ROME, JA
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1072 - 1072
  • [9] Monte Carlo simulation of the neutron measurement for the Large Helical Device deuterium experiments
    Nishitani, Takeo
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    [J]. FUSION ENGINEERING AND DESIGN, 2017, 123 : 1020 - 1024
  • [10] Extension of high power deuterium operation of negative ion based neutral beam injector in the large helical device
    Ikeda, K.
    Tsumori, K.
    Nagaoka, K.
    Nakano, H.
    Kisaki, M.
    Fujiwara, Y.
    Kamio, S.
    Haba, Y.
    Masaki, S.
    Osakabe, M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (11):