Extension of high power deuterium operation of negative ion based neutral beam injector in the large helical device

被引:14
|
作者
Ikeda, K. [1 ]
Tsumori, K. [1 ,2 ]
Nagaoka, K. [1 ,3 ]
Nakano, H. [1 ,2 ]
Kisaki, M. [1 ,2 ]
Fujiwara, Y. [1 ]
Kamio, S. [1 ]
Haba, Y. [3 ]
Masaki, S. [2 ]
Osakabe, M. [1 ,2 ]
机构
[1] Natl Inst Nat Sci, NIFS, 322-6 Oroshi, Toki, Gifu 5095292, Japan
[2] Grad Univ Adv Studies, SOKENDAI, 322-6 Oroshi, Toki, Gifu 5095292, Japan
[3] Nagoya Univ, Grad Sch Sci, Nagoya, Aichi 4648603, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2019年 / 90卷 / 11期
关键词
SYSTEM; FIELD;
D O I
10.1063/1.5128529
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Second deuterium operation of the negative ion based neutral beam injector was performed in 2018 in the large helical device. The electron and ion current ratio improves to I-e/I-acc(D) = 0.31 using the short extraction gap distance of 7mmbetween the plasma grid (PG) and the extraction grid (EG). The strength of the magnetic field by the electron deflection magnet installed in the EG increases by 17% at the PG ingress surface, which effectively reduces the electron component in the negative ion rich plasma in the vicinity of PG apertures. The reduction of the electron current made it possible to operate at a high power arc discharge and beam extraction. Then, the deuterium negative ion current increases to 55.4 A with the averaged current density of 233 A/m(2). The thermal load on the EG using 7 mm gap distance is 0.6 times smaller than the thermal load using a 8 mm gap caused by the reduction of coextracted electron current. The injection beam power increases to 2.9MWin the beam line BL3, and the total beam injection power increases to 7MWby three beam lines in the second deuterium campaign. Published under license by AIP Publishing.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Development of negative ion based neutral beam injector for the large helical device
    Kaneko, O
    Takeiri, Y
    Tsumori, K
    Oka, Y
    Osakabe, M
    Akiyama, R
    Kawamoto, T
    Asano, E
    Kuroda, T
    FUSION ENERGY 1996, VOL 3, 1997, : 539 - 545
  • [2] Improvement of a large negative ion source for the Large Helical Device neutral beam injector
    Takeiri, Y
    Ikeda, K
    Hamabe, M
    Osakabe, M
    Kaneko, O
    Oka, Y
    Tsumori, K
    Asano, E
    Kawamoto, T
    Sato, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 1087 - 1089
  • [3] Engineering prospects of negative-ion-based neutral beam injection system from high power operation for the large helical device
    Kaneko, O
    Takeiri, Y
    Tsumori, K
    Oka, Y
    Osakabe, M
    Ikeda, K
    Nagaoka, K
    Kawamoto, T
    Asano, E
    Sato, M
    NUCLEAR FUSION, 2003, 43 (08) : 692 - 699
  • [4] Negative hydrogen ion source development for large helical device neutral beam injector (invited)
    Takeiri, Y
    Kaneko, O
    Tsumori, K
    Oka, Y
    Osakabe, M
    Ikeda, K
    Asano, E
    Kawamoto, T
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1225 - 1230
  • [5] High-power negative ion sources for neutral beam injectors in Large Helical Device
    Takeiri, Y.
    Kaneko, O.
    Tsumori, K.
    Fantz, U.
    Ikeda, K.
    Nagaoka, K.
    Osakabe, M.
    Oka, Y.
    Asano, E.
    Kondo, T.
    Sato, M.
    Shibuya, M.
    Komada, S.
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2007, 925 : 211 - +
  • [6] DESIGN STUDY OF A NEGATIVE-ION-BASED NEUTRAL INJECTOR FOR THE LARGE HELICAL DEVICE
    KANEKO, O
    ANDO, A
    HANATANI, K
    OKA, Y
    OKAMOTO, M
    TAKEIRI, Y
    TSUMORI, K
    AKIYAMA, R
    KAWAMOTO, T
    KURODA, T
    FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 455 - 462
  • [7] Fabrication of negative-ion-based neutral beam injector for large helical devices
    Kaneko, O
    Murakami, S
    Oka, Y
    Osakabe, M
    Takeiri, Y
    Tsumori, K
    Akiyama, R
    Asano, E
    Kawamoto, T
    Kuroda, T
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1996, (380): : 453 - 462
  • [8] First Results of Deuterium Beam Operation on Neutral Beam Injectors in the Large Helical Device
    Ikeda, K.
    Tsumori, K.
    Kisaki, M.
    Nakano, H.
    Nagaoka, K.
    Osakabe, M.
    Kamio, S.
    Fujiwara, Y.
    Haba, Y.
    Takeiri, Y.
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2018, 2011
  • [9] High current H- ion sources for the large helical device neutral beam injector
    Oka, Y
    Tsumori, K
    Takeiri, Y
    Kaneko, O
    Osakabe, M
    Asano, E
    Kawamoto, T
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 920 - 922
  • [10] Initial long-pulse plasma heating at reduced power with negative-ion-based neutral beam injector in large helical device
    Takeiri, Y
    Noda, N
    Nakamura, Y
    Oka, Y
    Osakabe, M
    Kawahata, K
    Kaneko, O
    Tsumori, K
    Sato, M
    Mutoh, T
    Goto, M
    Ida, K
    Inagaki, S
    Kado, S
    Masuzaki, S
    Morita, S
    Nagayama, Y
    Peterson, BJ
    Sagara, A
    Sakakibara, S
    Sato, K
    Tanaka, K
    Sudo, S
    Ohyabu, N
    Motojima, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4260 - 4265