Optical Demonstration of THz, Dual-Polarization Sensitive Microwave Kinetic Inductance Detectors

被引:0
|
作者
B. Dober
J. A. Austermann
J. A. Beall
D. Becker
G. Che
H. M. Cho
M. Devlin
S. M. Duff
N. Galitzki
J. Gao
C. Groppi
G. C. Hilton
J. Hubmayr
K. D. Irwin
C. M. McKenney
D. Li
N. Lourie
P. Mauskopf
M. R. Vissers
Y. Wang
机构
[1] University of Pennsylvania,
[2] National Institute of Standards and Technology,undefined
[3] Arizona State University,undefined
[4] Stanford University,undefined
来源
Journal of Low Temperature Physics | 2016年 / 184卷
关键词
MKID; Sub-mm; THz; Polarimetry; Bolometer;
D O I
暂无
中图分类号
学科分类号
摘要
Polarization sensitive, microwave kinetic inductance detectors (MKIDs) are under development for the next generation BLAST instrument (BLAST-TNG). BLAST-TNG is a balloon-borne submillimeter polarimeter designed to study magnetic fields in diffuse dust regions and molecular clouds. We present the design and performance of feedhorn-coupled, dual-polarization sensitive MKIDs fabricated from TiN/Ti multilayer films, which have been optimized for the 250 μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\upmu $$\end{document}m band. Measurements show effective selection of linear polarization and good electrical isolation between the orthogonally crossed X and Y detectors within a single spatial pixel. The detector cross-polar coupling is <\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<$$\end{document}3 %. Passband measurements are presented, which demonstrate that the desired band-edges (1.0–1.4 THz) have been achieved. We find a near linear response to the optical load from a blackbody source, which has been observed in previous devices fabricated from TiN. Blackbody-coupled noise measurements demonstrate that the sensitivity of the detectors is limited by photon noise when the optical load is greater than 1 pW.
引用
收藏
页码:173 / 179
页数:6
相关论文
共 50 条
  • [21] Multi-chroic dual-polarization bolometric detectors for studies of the Cosmic Microwave Background
    Suzuki, Aritoki
    Arnold, Kam
    Edwards, Jennifer
    Engargiola, Greg
    Ghribi, Adnan
    Holzapfel, William
    Lee, Adrian T.
    Meng, Xiao Fan
    Myers, Michael J.
    O'Brient, Roger
    Quealy, Erin
    Rebeiz, Gabriel
    Richards, Paul
    Rosen, Darin
    Siritanasak, Praween
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [22] THz Leaky Lens Antenna Integrated with Kinetic Inductance Detectors
    Neto, A.
    Llombart, N.
    Baselmans, J.
    Baryshev, A.
    Yates, S.
    2013 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY (IWAT), 2013, : 12 - 14
  • [23] Multi-Chroic Dual-Polarization Bolometric Detectors for Studies of the Cosmic Microwave Background
    A. Suzuki
    K. Arnold
    J. Edwards
    G. Engargiola
    W. Holzapfel
    B. Keating
    A. T. Lee
    X. F. Meng
    M. J. Myers
    R. O’Brient
    E. Quealy
    G. Rebeiz
    P. L. Richards
    D. Rosen
    P. Siritanasak
    Journal of Low Temperature Physics, 2014, 176 : 650 - 656
  • [24] Multi-Chroic Dual-Polarization Bolometric Detectors for Studies of the Cosmic Microwave Background
    Suzuki, A.
    Arnold, K.
    Edwards, J.
    Engargiola, G.
    Holzapfel, W.
    Keating, B.
    Lee, A. T.
    Meng, X. F.
    Myers, M. J.
    O'Brient, R.
    Quealy, E.
    Rebeiz, G.
    Richards, P. L.
    Rosen, D.
    Siritanasak, P.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (5-6) : 650 - 656
  • [25] Tungsten Silicide Alloys for Microwave Kinetic Inductance Detectors
    Quaranta, Orlando
    Cecil, Thomas W.
    Miceli, Antonino
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [26] Tungsten silicide films for microwave kinetic inductance detectors
    Cecil, Thomas
    Miceli, Antonino
    Quaranta, Orlando
    Liu, Chian
    Rosenmann, Daniel
    McHugh, Sean
    Mazin, Benjamin
    APPLIED PHYSICS LETTERS, 2012, 101 (03)
  • [27] Antenna-coupled microwave kinetic inductance detectors
    Day, PK
    Leduc, HG
    Goldin, A
    Vayonakis, T
    Mazin, BA
    Kumar, S
    Gao, J
    Zmuidzinas, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 561 - 563
  • [28] Development of Microwave Kinetic Inductance Detectors for a Detection of Phonons
    Ishino, H.
    Kibayashi, A.
    Hattori, K.
    Hazumi, M.
    Kibe, Y.
    Mima, S.
    Sato, N.
    Yoshida, M.
    Watanabe, H.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 161 - 167
  • [29] A readout for large arrays of microwave kinetic inductance detectors
    McHugh, Sean
    Mazin, Benjamin A.
    Serfass, Bruno
    Meeker, Seth
    O'Brien, Kieran
    Duan, Ran
    Raffanti, Rick
    Werthimer, Dan
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (04):
  • [30] Development of Microwave Kinetic Inductance Detectors for a Detection of Phonons
    H. Ishino
    A. Kibayashi
    K. Hattori
    M. Hazumi
    Y. Kibe
    S. Mima
    N. Sato
    M. Yoshida
    H. Watanabe
    Journal of Low Temperature Physics, 2014, 176 : 161 - 167