Disruption of bioresorbable vascular scaffold struts due to loss of radial integrity: insights from optical coherence tomography

被引:0
|
作者
Ana Rita Ramalho
João Silva Marques
Guilherme Mariano Pêgo
机构
[1] Coimbra Hospital and Universitary Centre,Cardiology Department
关键词
Bioresorbable scaffold; Struts disruption; Optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Strut disruption of bioresorbable vascular scaffold is a known potential concern, although uncommon when adequate lesion preparation is achieved and nominal size of the scaffold is respected. It is usually difficult to detect with angiography and/or intravascular ultrasound. Three-dimensional reconstructions of optical coherence tomography facilitates understanding of complex luminal anatomy and configuration of stent struts, providing evaluation of stent integrity immediately after deployment and therefore optimization of the complex revascularization procedure. The present article reports a case where this image modality enabled successful use of a drug-eluting stent inside a bioresorbable vascular scaffold to restore the luminal integrity, jeopardized by struts disruption. This case highlights the need to better characterize coronary atherosclerotic disease complexity before considering bioresorbable vascular scaffold implantation. Optical coherence tomography imaging could be a useful tool for accurate selection of the most suitable lesions for bioresorbable stents and to guide the revascularization process, so that in the event of stent fracture it may be detected and managed in a timely fashion.
引用
收藏
页码:311 / 312
页数:1
相关论文
共 50 条
  • [31] Mechanisms of Very Late Bioresorbable Scaffold Thrombosis Assessed by Optical Coherence Tomography: Insights from the international INVEST registry
    Yamaji, Kyohei
    Ueki, Yasushi
    Souteyrand, Geraud
    Daemen, Joost
    Byrne, Robert
    Wiebe, Jens
    Hoppmann, Petra
    Nef, Holger
    Boeder, Niklas
    Adriaenssens, Tom
    Loh, Joshua
    Lattuca, Benoit
    Wykrzykowska, Joanna
    Lara, Josep Gomez
    Timmers, Leo
    Abdel-Wahab, Mohamed
    Meincke, Felix
    Honton, Benjamin
    O'Sullivan, Crochan
    Ielasi, Alfonso
    Christ, Guenter
    Lee, Joe
    Lee, Michael
    Amabile, Nicolas
    Karagiannis, Alexios
    Windecker, Stephan
    Raber, Lorenz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B4 - B5
  • [32] Bioresorbable vascular scaffold restenosis treated with sirolimus-eluting balloon: Optical coherence tomography findings
    Cuesta, Javier
    Garcia-Guimaraes, Marcos
    Bastante, Teresa
    Rivero, Fernando
    Maruri, Ramon
    Alfonso, Fernando
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2018, 37 (04) : 359 - 360
  • [33] Bioresorbable Scaffold T-stenting Evaluated With Optical Coherence Tomography
    Ortiz, Carlos
    Gutierrez, Hipolito
    San Roman, Jose A.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (11): : 949 - 949
  • [34] Imaging Comparison of a Bioresorbable Vascular Scaffold by High-Frequency Intravascular Ultrasound and Optical Coherence Tomography
    Shan, Peiren
    Motivala, Apurva
    Moses, Jeffrey
    Maehara, Akiko
    Mintz, Gary S.
    Ali, Ziad A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (11) : E187 - E188
  • [35] SERIAL ANALYSIS OF THE MALAPPOSED AND UNCOVERED STRUTS OF THE NEW GENERATION OF EVEROLIMUS-ELUTING BIORESORBABLE SCAFFOLD USING OPTICAL COHERENCE TOMOGRAPHY
    Gomez-Lara, Josep
    Radu, Maria D.
    Brugaletta, Salvatore
    Farooq, Vasim
    Diletti, Roberto
    Windecker, Stefan
    Whitbourn, Robert
    Dudeck, Dariusz
    Smits, Pieter C.
    Regar, Evelyn
    Garcia-Garcia, Hector M.
    Serruys, Patrick
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1680 - E1680
  • [36] Circumferential evaluation of the neointima by optical coherence tomography after ABSORB bioresorbable vascular scaffold implantation: Can the scaffold cap the plaque?
    Brugaletta, Salvatore
    Radu, Maria D.
    Garcia-Garcia, Hector M.
    Heo, Jung Ho
    Farooq, Vasim
    Girasis, Chrysafios
    van Geuns, Robert-Jan
    Thuesen, Leif
    McClean, Dougal
    Chevalier, Bernard
    Windecker, Stephan
    Koolen, Jacques
    Rapoza, Richard
    Miquel-Hebert, Karine
    Ormiston, John
    Serruys, Patrick W.
    ATHEROSCLEROSIS, 2012, 221 (01) : 106 - 112
  • [37] Optical Coherence Tomography Findings in Bioresorbable Vascular Scaffolds Thrombosis
    Cuculi, Florim
    Puricel, Serban
    Jamshidi, Peiman
    Valentin, Jeremy
    Kallinikou, Zacharenia
    Toggweiler, Stefan
    Weissner, Melissa
    Muenzel, Thomas
    Cook, Stephane
    Gori, Tommaso
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10)
  • [38] Impact of solution viscosity on measurements of everolimus bioresorbable vascular scaffold: an in-vitro optical coherence tomography analysis
    Nasu, K.
    Habara, M.
    Suzuki, T.
    EUROPEAN HEART JOURNAL, 2016, 37 : 492 - 492
  • [39] A broken promise: 4-year optical coherence tomography follow-up of a bioresorbable vascular scaffold
    Versaci, Francesco
    Vizzari, Giampiero
    Prati, Francesco
    Biondi-Zoccai, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2020, 21 (05) : 398 - 400
  • [40] Follow-up evaluation of unapposed bioresorbable vascular scaffold at a coronary bifurcation using optical coherence tomography
    Danson, E.
    Bhindi, R.
    Hansen, P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (02) : E84 - E86