Coronoid plate fixation of type II and III coronoid process fractures: outcome and prognostic factors

被引:0
|
作者
Sang Ki Lee
Ha Yong Kim
Kap Jung Kim
Dae Suk Yang
Won Sik Choy
机构
[1] Eulji University College of Medicine,Department of Orthopedic Surgery
关键词
Coronoid process fracture; Coronoid plate; Elbow;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of the present study was to determine the clinical outcome and prognostic factors after applying the coronoid plate fixation technique who had sustained type II or III coronoid process fractures. Fifteen consecutive patients were enrolled in this study. The mean arc of flexion–extension was 116° with a mean flexion and flexion contracture of 126° and 11°, respectively. The mean arc of forearm rotation was 158° with a mean pronation and supination of 78° and 80°, respectively. The mean Mayo Elbow Performance Score (MEPS) was 88 points (range, 70–100 points), which corresponded to an excellent result in ten elbows, good result in four and fair result in one. All the isolated coronoid fractures (8 patients) (there was no combined injury) and nine of the eleven (82%) noncomminuted coronoid fractures (the existence of one or two fracture fragments) had excellent functional results in accordance with the MEPS (average MEPS was 93.8 and 93.3, respectively). Patients with less favorable results according to the MEPS had lateral side injuries, such as lateral collateral ligament injures or radial head fractures (mean MEPS 78.0) The average functional score (MEPS) of the patients showing signs of arthritic changes was 76.7. Based on our experience, coronoid plate fixation of type II and III coronoid process fractures is an acceptable and alternative method that can provide good results. However, acceptable clinical outcomes are not only related to the successful rigid internal fixation of the coronoid fracture but depend on the severity of the primary injury and associated soft tissue injuries. The comminution of the fracture fragment, associated lateral collateral ligament injuries, and posttraumatic arthritic changes can be considered indicators of a poor functional outcome.
引用
收藏
页码:213 / 219
页数:6
相关论文
共 50 条
  • [21] Plate osteosynthesis of the coronoid process of the ulna
    Rausch, Valentin
    Hackl, Michael
    Seybold, Dominik
    Wegmann, Kilian
    Mueller, Lars P.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2020, 32 (01): : 35 - 46
  • [22] Direct anterior approach for mini plate fixation of Regan-Morrey type II comminuted ulnar coronoid process fracture
    Shen, Jian-Jian
    Qiu, Qing-Mi
    Gao, Yi-Bin
    Tong, Song-Lin
    Huang, Jie-Feng
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (01) : 1 - 6
  • [23] Operative Fixation of the Anteromedial Facet of the Coronoid Process
    Kingery, Matthew T.
    Lowe, Dylan T.
    Egol, Kenneth A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 : S7 - S8
  • [24] Surgical treatment of acute coronoid process fractures
    Nalbantoglu, Ufuk
    Gereli, Arel
    Kocaoglu, Baris
    Haklar, Ugur
    Turkmen, Metin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (02) : 112 - 118
  • [25] Classification of coronoid process fractures: A pending question
    Wang, Daofeng
    Li, Jiantao
    Xu, Gaoxiang
    Zhang, Wupeng
    Li, Li
    Tang, Peifu
    Zhang, Licheng
    FRONTIERS IN SURGERY, 2022, 9
  • [26] HEALING OF FRACTURES OF THE CORONOID PROCESS - REPORT OF CASES
    TAKENOSHITA, Y
    ENOMOTO, T
    OKA, M
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (02) : 200 - 204
  • [27] Fracture of the Coronoid Process Associatedwith Frontosphenoidal Fractures
    Baliga, Mohan
    Baptist, Joanna
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (04) : 330 - 332
  • [28] Lasso plate - An original implant for fixation of type I and II Regan-Morrey coronoid fractures (vol 103, pg 447, 2017)
    Wang, P.
    Zhuang, Y.
    Li, Z.
    Wei, W.
    Fu, Y.
    Wei, X.
    Zhang, K.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (05) : 825 - 825
  • [29] Minimal invasive percutaneous plate osteosynthesis for complex monteggia fracture with type III coronoid process fracture
    Jeon, IH
    Oh, CW
    Kim, PT
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (06): : 631 - 633
  • [30] Joint capsule attachment to the coronoid process of the ulna: an anatomic study with implications regarding the type 1 fractures of the coronoid process of the O'Driscoll classification
    Shimura, Haruhiko
    Nimura, Akimoto
    Nasu, Hisayo
    Fujishiro, Hitomi
    Imatani, Junya
    Okawa, Atsushi
    Akita, Keiichi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (09) : 1517 - 1522