Coronoid plate fixation of type II and III coronoid process fractures: outcome and prognostic factors

被引:0
|
作者
Sang Ki Lee
Ha Yong Kim
Kap Jung Kim
Dae Suk Yang
Won Sik Choy
机构
[1] Eulji University College of Medicine,Department of Orthopedic Surgery
关键词
Coronoid process fracture; Coronoid plate; Elbow;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of the present study was to determine the clinical outcome and prognostic factors after applying the coronoid plate fixation technique who had sustained type II or III coronoid process fractures. Fifteen consecutive patients were enrolled in this study. The mean arc of flexion–extension was 116° with a mean flexion and flexion contracture of 126° and 11°, respectively. The mean arc of forearm rotation was 158° with a mean pronation and supination of 78° and 80°, respectively. The mean Mayo Elbow Performance Score (MEPS) was 88 points (range, 70–100 points), which corresponded to an excellent result in ten elbows, good result in four and fair result in one. All the isolated coronoid fractures (8 patients) (there was no combined injury) and nine of the eleven (82%) noncomminuted coronoid fractures (the existence of one or two fracture fragments) had excellent functional results in accordance with the MEPS (average MEPS was 93.8 and 93.3, respectively). Patients with less favorable results according to the MEPS had lateral side injuries, such as lateral collateral ligament injures or radial head fractures (mean MEPS 78.0) The average functional score (MEPS) of the patients showing signs of arthritic changes was 76.7. Based on our experience, coronoid plate fixation of type II and III coronoid process fractures is an acceptable and alternative method that can provide good results. However, acceptable clinical outcomes are not only related to the successful rigid internal fixation of the coronoid fracture but depend on the severity of the primary injury and associated soft tissue injuries. The comminution of the fracture fragment, associated lateral collateral ligament injuries, and posttraumatic arthritic changes can be considered indicators of a poor functional outcome.
引用
收藏
页码:213 / 219
页数:6
相关论文
共 50 条
  • [1] Coronoid plate fixation of type II and III coronoid process fractures: outcome and prognostic factors
    Lee, Sang Ki
    Kim, Ha Yong
    Kim, Kap Jung
    Yang, Dae Suk
    Choy, Won Sik
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 (03): : 213 - 219
  • [2] Buttress plate fixation of coronoid process fractures via a medial approach
    LorKelvinKahHo
    ToonDongHao
    WeeAndyTeckHuat
    中华创伤杂志英文版, 2019, (05) : 255 - 260
  • [3] Buttress plate fixation of coronoid process fractures via a medial approach
    Lor, Kelvin Kah Ho
    Toon, Dong Hao
    Wee, Andy Teck Huat
    CHINESE JOURNAL OF TRAUMATOLOGY, 2019, 22 (05) : 255 - 260
  • [4] Functional outcome after operative treatment of eight type III coronoid process fractures
    Jeon, IH
    Oh, CW
    Kyung, HS
    Park, BC
    Kim, PR
    Ihn, JC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (02): : 416 - 421
  • [5] Efficacy and outcome of open reduction and internal fixation with mini-plate in ulnar coronoid process fractures
    Chen, Hongwei
    Pan, Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 8858 - 8864
  • [6] Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures
    Chen, Hong-Wei
    He, Hong-Hui
    Gao, Bin-Li
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [7] Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures
    Hong-Wei Chen
    Hong-Hui He
    Bin-Li Gao
    BMC Musculoskeletal Disorders, 19
  • [8] Anterior approach for fixation of isolated type III coronoid process fracture
    Han S.-H.
    Yoon H.-K.
    Rhee S.-Y.
    Lee J.-K.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (4) : 395 - 405
  • [9] Lasso plate - An original implant for fixation of type I and II Regan-Morrey coronoid fractures
    Wang, P.
    Zhuang, Y.
    Li, Z.
    Wei, W.
    Fu, Y.
    Wei, X.
    Zhang, K.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (03) : 447 - 451
  • [10] Fractures of the coronoid process
    Cohen, MS
    HAND CLINICS, 2004, 20 (04) : 443 - +