摘要
A procedure is described for choosing the optimum pulse amplitude interval for a proportional counter when the useful signal level is comparable with the natural background level. It is shown that the optimum interval for counter pulses having a Gaussian amplitude distribution function corresponds to 1.4σ. The application of the procedure is demonstrated in a test example with processing of the iron Kα x-ray spectrum.
引用
收藏
页码:596 / 597
页数:1
相关论文
共 50 条
  • [31] ALUMINIUM PROPORTIONAL COUNTER FOR THE MEASUREMENT OF LOW FAST NEUTRON FLUX
    GLOVER, RN
    NUCLEAR INSTRUMENTS & METHODS, 1958, 3 (06): : 316 - 319
  • [32] HIGH-PRESSURE PROPORTIONAL COUNTER AT LOW-TEMPERATURES
    GREBENNIK, VG
    DODOKHOV, VK
    ZHUKOV, VA
    LAZAREV, AB
    NOZDRIN, AA
    STOLUPIN, VA
    TRAVKIN, VI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (05) : 1225 - 1227
  • [33] A proportional counter for low intensity heavy ion flow measurements
    Yu. G. Teterev
    G. A. Kononenko
    Instruments and Experimental Techniques, 2011, 54 : 585 - 589
  • [34] A proportional counter for low intensity heavy ion flow measurements
    Teterev, Yu. G.
    Kononenko, G. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2011, 54 (04) : 585 - 589
  • [35] LOW-BACKGROUND PROPORTIONAL RESONANCE COUNTER FOR MOSSBAUER STUDIES
    MEDVEDEVA, NS
    SOMOV, VN
    KORYTKO, LA
    TOLSTIKOV, AN
    TOSHCHAKOV, EK
    SOZINOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (01) : 49 - 52
  • [36] CHARACTERISTICS OF A HIGH-PRESSURE, LOW BACKGROUND PROPORTIONAL COUNTER
    KUZMINOV, VV
    NOVIKOV, VM
    PRITICHENKO, BV
    POMANSKY, AA
    POVINEC, P
    JANIK, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 17 (5-6): : 452 - 453
  • [38] TESTING A LOW-LEVEL COUNTER
    ABELA, R
    BACKENSTOSS, G
    KOWALD, W
    WUEST, J
    SEILER, HG
    SEILER, M
    SIMONS, LM
    HELVETICA PHYSICA ACTA, 1980, 52 (03): : 416 - 416
  • [39] LOW-LEVEL NEEDLE COUNTER
    FUJITA, Y
    TAGUCHI, Y
    IMAMURA, M
    INOUE, T
    TANAKA, S
    NUCLEAR INSTRUMENTS & METHODS, 1975, 128 (03): : 523 - 524
  • [40] Exploring background variability of a low-level (quartz) gas proportional counter using pulse shape and distribution analysis
    Klouda, George A.
    Filliben, James J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 997 - 1003